• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    The journal of extra-corporeal technology

    The journal of extra-corporeal technology

    JournalISSN 2969-8960

    年发文量

    研究主题

    论文(2584)

    排序
    1The Modern Perfusion Leader: Leading Data-Driven Quality Improvement, Standardization, Innovation, and Patient Outcomes
    Salman Pervaiz Butt, Sundar Subramanian,Salman Abdulaziz,Gopal Bhatnagar
    2026
    引用
    AI阅读
    加入学术空间
    2Incidence of Hemolysis During Deep Hypothermic Circulatory Arrest Surgery.
    Sylvain DIOP, Hamdi Ghadbane,Elie Fadel, Sophie Bourriquet, Maria Cristina Kassab, Nicolas Mavambu,Jacques Thes
    2026
    引用
    AI阅读
    加入学术空间
    3Avoiding Secondary Hemodilution During Planned Temporary Right Ventricular Assist Device Implantation: an Autologous Priming Technique
    Anthony George Shackelford

    Background: Temporary right ventricular assist device (RVAD) support is used during selected high-risk cardiac operations, including durable left ventricular assist device implantation, orthotopic heart transplantation, and procedures complicated by anticipated right ventricular failure. When RVAD implantation is planned during cardiopulmonary bypass (CPB), the RVAD circuit is commonly primed with crystalloid solution. Although 500-600 mL may appear modest in many adult patients, this secondary circuit prime may produce clinically meaningful hemodilution in patients who are frequently anemic, volume loaded, and near transfusion thresholds, where relatively small changes in hematocrit may alter clinical management. Technique: This report describes an autologous priming technique that uses patient blood available during CPB to displace crystalloid from the RVAD circuit before completion of the outflow connection. The technique requires no change to the conventional RVAD circuit, adds minimal time, and can be discontinued at any point if patient conditions do not safely permit further displacement. Discussion: This technique applies established autologous priming principles to a secondary extracorporeal circuit introduced after CPB has already been established. The objective is to avoid an unnecessary crystalloid load, minimize secondary hemodilution, and preserve hematocrit at the margin where transfusion decisions are commonly made. Conclusion: Autologous priming of the RVAD circuit during planned implantation is a simple, reproducible, patient-directed technique for minimizing secondary hemodilution while preserving conventional RVAD deployment.

    2026
    引用
    AI阅读
    加入学术空间
    4Case Report: Catastrophic Thrombotic Complication of the VA-ECMO Circuit Following TEVAR in a Patient with Sickle Cell Anemia. ​
    Juan Carlos Kling, Paula Santamaria, María Angélica Echeverry Castaño, Hean Pool Gómez López, María José Carreño-Matiz

    Mechanical circulatory support in sickle cell anemia patients undergoing complex cardiovascular surgery remains a subject of controversy. This is due to the risk of vaso-occlusive and prothrombotic phenomena associated with hypoxia, acidosis, inflammation, and contact with non-endothelialized surfaces. However, veno arterial extracorporeal membrane oxygenation (VA-ECMO) is employed as a rescue therapy in refractory shock scenarios. We describe the case of a 62-year-old patient with a history of sickle cell anemia and thoracic endovascular aortic repair (TEVAR), who was admitted for massive hemoptysis and severe hypoxemic respiratory failure. Imaging findings suggested infection of the aortic endoprosthesis. The patient underwent complex reconstruction of the aortic arch and ascending aorta, complicated by massive bleeding, requiring emergency left pneumonectomy. Patient developed refractory shock and deoxygenation requiring VA-ECMO. Thirty minutes later, the circuit presented massive thrombosis, resulting in a fatal outcome. This case underscores the profound risks associated with the convergence of sickle cell anemia, complex aortic surgery, and VA-ECMO. ​

    2026
    引用
    AI阅读
    加入学术空间
    5Quantifying Oxygenator Performance in Extracorporeal Membrane Oxygenation: Validation and Transfer of the Hamilton Methodology to Long-Term Support
    David Max Riesterer, Lena Speiser,Folker Wenzel, Peter Rose,Dania Fischer, Markus Demuth, Sandor Gyuege,Matthias Karck,Jan Turra

    Background Maintaining adequate oxygen delivery is critical in extracorporeal membrane oxygenation (ECMO), yet monitoring oxygenator performance remains largely dependent on reactive blood gas analysis (BGA) and subjective visual inspections. While Hamilton et al. developed a methodology to quantify gas exchange efficiency for short-term cardiopulmonary bypass (CPB), its applicability to long-term ECMO support has not been established. This study aimed to adapt and validate this model for real-time monitoring of ECMO oxygenator degradation. Methods In this monocentric, retrospective study, we analyzed 2,441 pre- and post-oxygenator BGA pairs from 164 patients treated with either the Quadrox PLS® (n=66) or A.L.ONE® (n=101) oxygenator. We adapted the Hamilton equation to calculate a corrected fraction of inspired oxygen FiO2 (cFiO2), normalizing performance to a target arterial partial pressure of oxygen (PaO2) of 150 mmHg. Statistical equivalence between measured and predicted oxygen transfer (VO2) was assessed using Two One-Sided Tests (TOST) and linear regression stratified by oxygenator runtime. Results Both oxygenator models demonstrated high correlation between VO2 and cFiO2. Performance degradation over time was successfully quantified through shifting regression slopes. TOST analysis confirmed statistical equivalence (α = 0.05) between the model’s predictions and clinical BGA data, indicating high predictive accuracy across various clinical states. Conclusion The Hamilton methodology can be effectively transferred to the ECMO setting, providing an objective, real-time tool to monitor membrane efficiency. By normalizing for patient-side variables, this mathematical framework allows for the early detection of oxygenator dysfunction, potentially facilitating proactive device exchange and improving patient safety.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 2584 篇论文

    高被引作者

    作者引用发文
    Riley Jeffrey B162999
    Stammers Alfred H127658
    Donald S. Likosky96532
    Robert Groom85936
    Stammers A H81628
    Bruce Searles77033
    Sistino Joseph J75229
    David Fitzgerald62521
    Gregory S Matte53016
    Edward Darling51123

    高产作者

    作者引用发文
    Riley Jeffrey B162999
    Stammers Alfred H127658
    Robert Groom85936
    Bruce Searles77033
    Donald S. Likosky96532
    Sistino Joseph J75229
    Stammers A H81628
    Edward Darling51123
    James P. Dearing16122
    David Fitzgerald62521

    相关期刊

    Seminars in cardiothoracic and vascular anesthesia
    Annals of cardiac anaesthesia
    JA clinical reports
    ASAIO Journal
    Thoracic and Cardiovascular Surgeon
    Anesteziologie a Intenzivni Medicina
    Current Opinion in Anesthesiology
    A & A PRACTICE
    Revista Española de Anestesiología y Reanimación (English Edition)
    Journal of Emergency and Critical Care Medicine