
Post-mortem CT angiography (PMCTA) is increasingly used in forensic death investigation to assess vascular disease, haemorrhage, and traumatic or natural vascular causes of death. However, its practical value depends on the lesion being investigated, the angiographic protocol, and the way imaging findings are integrated with autopsy and pathology. This systematic review evaluated the diagnostic performance, added value, and main pitfalls of PMCTA for fatal vascular lesions. PubMed/MEDLINE, Embase, Scopus, and Cochrane/CENTRAL were searched for human post-mortem studies evaluating PMCTA in forensic, medico-legal, coronial, or post-mortem settings. Eligible studies compared PMCTA with autopsy, histopathology, targeted vascular dissection, or autopsy-based consensus. Evidence was grouped according to practical forensic use, including coronary stenosis assessment, autopsy triage, global vascular lesion detection, haemorrhage-source localization, aortic or traumatic vascular injury assessment, coronary plaque characterization, and artifact-related pitfalls. Risk of bias was assessed using a QUADAS-2-based approach adapted to forensic PMCTA studies. The available evidence did not support unrestricted pooling of all fatal vascular lesions. PMCTA was used for different forensic questions, and only coronary stenosis provided data close to conventional diagnostic accuracy assessment. In this domain, available studies showed high specificity but only moderate sensitivity for critical stenosis. Autopsy-triage studies suggested that PMCTA may reduce or guide invasive autopsy in selected adult coronial workflows. Global comparison studies showed added value for vascular lesion detection, and haemorrhage-source studies suggested that PMCTA may help localize bleeding vessels. Evidence on fatal coronary plaque characterization is emerging. Pitfall studies showed that post-mortem clots, incomplete vascular filling, contrast leakage, and extravasation artifacts may mimic or obscure vascular pathology. PMCTA is best interpreted as a complementary tool in forensic vascular death investigation rather than as a general substitute for autopsy. Its contribution is strongest when it answers a specific vascular question, such as documenting coronary stenosis, guiding autopsy, mapping vascular lesions, localizing haemorrhage, or supporting targeted histopathology. Careful correlation with autopsy, pathology, case circumstances, and protocol-related artifacts remains essential.
This study reports the genetic diversity and phylogenetic relationships of 24 autosomal short tandem repeat (STR) loci in 210 unrelated Santhal individuals from the Lakhisarai and Jamui districts of Bihar, India, genotyped with the Ingenomics™ AutoProfiler STR Kit. All 24 loci were polymorphic and forensically informative: polymorphism information content ranged from 0.601 (CSF1PO) to 0.933 (SE33), power of discrimination from 0.814 to 0.988 and power of exclusion from 0.428 to 0.913, with a combined probability of match of 2.41 × 10⁻²⁸ and a combined power of exclusion of 0.999999999991. No locus deviated significantly from Hardy–Weinberg equilibrium. Population relationships were examined against 34 previously published, geographically and ethnically relevant Indian datasets using a neighbour-joining tree based on Nei’s Dₐ genetic distance and a principal component analysis of allele frequencies. The neighbour-joining tree placed the Bihar Santhal adjacent to the Munda population of Jharkhand, consistent with the shared Austroasiatic ancestry of the two groups in the Chotanagpur region, although bootstrap support for this node was low. In the principal component analysis the Santhal fell within a dense central cluster containing most of the eastern, northern and central Indian populations examined, with the first two components accounting for 81.47
Short tandem repeat(STR) typing is widely used in parentage testing and forensic identification. However, atypical genotyping results of tri-allelic patterns with three alleles at a single autosomal STR locus often complicates forensic interpretation. Here we report a novel Type I tri-allelic pattern at the Penta E locus (13,19,20) in a Chinese family, which has not been documented in the STRBase database. Through re-amplification with a different commercial kit and sequencing validation, we confirmed it as a genuine Type I pattern resulting from a somatic mutation. We further analyzed the peak height ratios of three imbalanced alleles at the Penta E locus in blood, oral swabs and hair with follicles, suggesting that the somatic mutation occurred during the differentiation of ectoderm and mesoderm layers. The maternity index for Penta E was calculated using two approaches, both supporting the parent‑child relationship. This case elucidates the formation mechanism of tri-allelic patterns, provides valuable data for refining kinship testing and evidence evaluation in forensic practice and highlights the need for standardized interpretation guidelines in forensic casework.
Post-mortem diagnosis of acute myocardial infarction (AMI) remains one of the major challenges in forensic pathology, as conventional macroscopic, histological and immunohistochemical techniques lack sufficient sensitivity within the first hour after onset of ischaemia. Using the established isolated-perfused rat heart model according to Langendorff, this study aimed to evaluate the feasibility and diagnostic potential of myocardial microRNA (miRNA) expression analysis for detecting very early ischaemic conditions. Myocardial expression patterns of four cardiac-enriched miRNAs (miRNA-1-3p, miRNA-133a-3p, miRNA-208a-3p and miRNA-499-5p) were investigated. After 30 min of ischaemia, distinct upregulation of miRNA-1 and miRNA-499 was observed in ischaemic myocardium. Following prolonged ischaemia of 240 min, expression levels of all four miRNAs declined in ischaemic myocardial tissue. These findings suggest an early, transient increase in selected cardiac-enriched miRNAs followed by a decrease with ongoing ischaemia, reflecting a dynamic, time-dependent regulation pattern. Our data demonstrate that myocardial miRNA alterations occur within 30 min of ischaemia. Specifically, we identified miRNA-1 and miRNA-499 as promising early indicators of acute ischemic myocardial injury. Thus, miRNA expression profiling may serve as a valuable adjunct to established forensic diagnostic approaches, particularly when survival times are short and conventional morphological methods reach their limits. Further validation in human post-mortem material is necessary to confirm the diagnostic applicability.
Sex estimation is fundamental in forensic anthropology and bioarchaeology, yet classical methods rely on skeletal elements that are often absent or poorly preserved. The bony labyrinth, enclosed within the petrous bone, is a promising alternative owing to its early maturation and taphonomic resistance, and cochlear shape has been reported to carry a sex-specific signal. However, most approaches depend on manual segmentation, micro-CT, or complex shape-analysis frameworks that limit routine applicability. To evaluate the feasibility of a semi-automated method for sex estimation from the cochlea using standard clinical CT and automated OTOPLAN segmentation, and to quantify the contribution of shape descriptors beyond cochlear size alone. We analyzed 139 cochleae from 87 adults using clinical CT scans (slice thickness ≤ 0.6 mm). The three-dimensional lateral wall path was extracted with OTOPLAN; after normalization and resampling, curvature- and torsion-based descriptors and scalar cochlear metrics were computed to train a supervised classifier. Preprocessing, feature, and hyperparameter choices were optimized by Bayesian optimization within a nested cross-validation, so that model selection and performance estimation used separate data. Six feature configurations were compared, with all partitions made at the patient level and the whole procedure repeated over five random partitions. In nested cross-validation, the best configurations reached an area under the ROC curve (AUC-ROC) of approximately 0.71. A model using cochlear diameter as its sole predictor did not differ detectably from those combining size and shape descriptors (AUC-ROC 0.71, 95