protection remains a critical issue along with modulator reliability, efficiency and cost. Configurations whereby multiple klystrons are paralleled on a single modulator may exacerbate the problem. The majority of this paper will discuss tests at SLAC of klystron arcs on Line-type modulators with single and double klystron loads. This talk may introduce and refer to other talks at this conference and other conferences by National and Foreign Laboratory collaborators and Industry, specifically in relation to DOE SBIR programs.