This paper presents results of analysis performed on a physiologic time-series dataset that was collected from a wearable ECG monitoring system worn by individuals who suffer from panic disorder. Models are constructed and evaluated for distinguishing between pathologic and non-pathologic states, including panic (during panic attack), pre-panic (preceding panic attack) and non-panic (outside panic attack window). The models presented use data fusion to combine both traditional time and frequency domain heart rate variability analysis together with nonlinear/complexity analysis. The best performing model is shown to be a random forest classifier that achieves an accuracy of 97.2% and 90.7% for recognizing states of panic and pre-panic , respectively. The models presented have application in pervasive and ubiquitous mobile and wearable health management systems.
更多
查看译文
关键词
Physiological Time Series,Psychometric Models,Nonstationary Time Series