A spectrometer measuring energy lost (deltaE) was used to determine linear energy transfer (LET) spectra on board the Mir orbital station during the period from 8 October 1997 to 16 June 2000, i.e. during the 24th, 26th, 27th and 28th basic expeditions. It was found that the LET spectra of secondary particles between 10 and 700 keV.microm(-1) in tissue do not depend on the external radiator, with the average quality factors for the region mentioned being about 6.4 with ICRP 26 quality factors or about 7.4 with ICRP 60 quality factors. Both differential and integral LET spectra are presented for some typical cases. The spectra permitted us to calculate the total doses and dose equivalents due to particles with the LET values in the mentioned region. It was found that these doses are higher when the detector was placed in a less shielded area. It was also found that these doses vary from one expedition to another. The correlation of these variations with the solar activity level was studied.
Three types of detectors were used onboard the MIR station during the 28th base expeditions to characterise the radiation field: a linear energy transfer (LET) spectrometer was used to establish the LET spectrum between 7 and 700keV/μm corresponding mostly to secondary charged particles; a set of thermoluminescent detectors was used to characterise the low LET component of the onboard radiation field; and Si-diodes were installed to determine the contribution to the exposure due to fast neutrons.It was found out that the LET spectrum from secondary particles between 7 and 700KeV/μm does not depend on the external radiator; the average quality factors for the region mentioned are about 6.0 with ICRP 26 quality factors and about 6.8 with ICRP 60 quality factors. Both differential and integral LET spectra are presented for some typical cases, not only for particle number but also for the dose characteristics like dose and dose equivalent.The spectra obtained also permitted us to calculate the total doses and dose equivalents due to secondary particles with the LET values between 7 and 700keV/μm. It was found out that these quantities are higher for the case of detectors placed in the less shielded area, both for the LET spectrometer (high LET part) as well as for TLDs measuring the low LET component.Total dosimetric characteristics obtained as a sum of both components mentioned are a little lower than previously reported.
Results of the experiments on neutron energy spectra measurements within broad energy range from 5 x 10(-7) to 2 x 10(2) MeV aboard the Mir orbital station and equivalent neutron dose estimation are presented. Four measurement techniques were used during the experiments. The shape of spectra and their absolute values are in good agreement. According to those experiments, an equivalent neutron dose depends upon effective shielding thickness and spacecraft mass. The neutron dose mentioned is comparable with that of ionizing radiation. Neutron flux levels measured aboard the Mir station have shown that a neutron spectrometer involving broad energy range will be used within the radiation monitoring systems in manned space flights.
The results of probing the radiation environment on board different civil aviation planes with singletype detectors (nuclear emulsions), with particular emphasis to the cosmic radiation flux measured inside aircraft, are presented. The measurement results make it possible to find the absorbed and equivalent doses induced by the cosmic radiation neutrons and charged particles.
High energ protons and photons an not able to form directly a track in an etch detector (TED). Such detectors can, however, be used for the detection and the dosimetry in the fields and beams of these radiation through the registration of secondary charged particles with sufficiently high values of linear energy transfer (LET). Analysis of tracks parameters of these secondary particles allows for the assessment of their LET spectra, and from them many other dosimetric information can be deduced.LET spectra of secondary particles have been established in high energy proton beams (E-p is an element of <80;250>MEV), high energ bremsstrahlung photon beams (E-max less than or equal to 50MV) and on the board of a satellite during a radiobiological experiment. Dose and dose equivalent distributions have been calculated from these spectra, the contribution of secondary particles to the total dose characteristics is appreciated and discussed.
A joint NASA Russia study of the radiation environment inside the Space Shuttle was performed on STS-63. This was the second flight under the Shuttle-Mir Science Program (Phase 1). The Shuttle was launched on 2 February 1995, in a 51.65° inclination orbit and landed at Kennedy Space Center on 11 February 1995, for a total flight duration of 8.27 days. The Shuttle carried a complement of both passive and active detectors distributed throughout the Shuttle volume. The crew exposure varied from 1962 to 2790 μGy with an average of 2265.8 μGy or 273.98 μGy/day. Crew exposures varied by a factor of 1.4, which is higher than usual for STS mission. The flight altitude varied from 314 to 395 km and provided a unique opportunity to obtain dose variation with altitude. Measurements of the average east-west dose variation were made using two active solid state detectors. The dose rate in the Spacehab locker, measured using a tissue equivalent proportional counter (TEPC), was 413.3 μGy/day, consistent with measurements made using thermoluminescent detectors (TLDs) in the same locker. The average quality factor was 2.33, and although it was higher than model calculations, it was consistent with values derived from high temperature peaks in TLDs. The dose rate due to galactic cosmic radiation was 110.6 μGy/day and agreed with model calculations. The dose rate from trapped particles was 302.7 μGy/day, nearly a factor of 2 lower than the prediction of the AP8 model. The neutrons in the intermediate energy range of 1–20 MeV contributed 13 μGy/day and 156 μSv/day, respectively. Analysis of data from the charged particle spectrometer has not yet been completed.
This paper describes the neutron energy spectra measured inside and outside the Mir space station. The measurements were made during the second half of 1991 with nuclear emulsions and a neutron and recoil proton spectrometer, whose output data was telemetry-transmitted. In the fast-neutron (En > 1.0 MeV) range, the measurements were carried out using the method of recoil protons in a stack of nuclear photoemulsions (NPE) and in an organic scintillator. To determine spectra of intermediate-energy resonance neutrons (1.0 MeV ≥ En ≥ 10−2 MeV), an attempt was made to use the NPE method by adding lithium salts. The measurements are characterized by long-term (133 days) exposures of passive detectors and by sizeable effective shielding thicknesses of the inside detector estimated to be ∼40 g cm−2. The experimental results are compared with each other and with the data published elsewhere. The neutron spectra measured are used to calculate the equivalent dose rates inside and outside the Mir station in various neutron energy ranges. The equivalent neutron dose estimated by measuring the spectra in the (1–10 MeV) range only (as done in earlier works) is observed to entail substantial underestimating of the true neutron dose. Comparison is made of the calculated neutron doses with similar calculations of ionizing-radiation doses for shielding thickness of ∼ 40 g cm−2. It is emphasized that the study should be continued.
A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on Space Shuttle flight STS-57 was conducted. The Shuttle flew in a nearly circular orbit of 28.5 degrees inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTDs) and thermoluminescent detectors (TLDs), and Russian nuclear emulsions, PNTDs and TLDs. All the detector systems were shielded by the same Shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micrometers and 200 keV/micrometers. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than the TLDs, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLDs to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.
Radiation environment on board STS-55 and 57 is estimated using experimental and calculated data.
Heavy nuclei transport in matter are studied experimentally and theoretically. Our experimental range and straggling values of 0.2 – 1.0 GeV/nucleon 20Ne, 40Ar, 56Fe, 197Au and 238U nuclei in BR-2 nuclear photoemulsion are presented and compared with model calculations carried out according to our RANGE-program and the PRAL-model (version of 1987) developed by Ziegler et al. The presented data analysis points at the necessity to take into account Z3-correction in Bete-Bloch formula when ionization losses of very heavy multicharge ions (for example 197Au and 238U) are calculated. The comparison of experimental and calculated results showed that RANGE program can correctly calculate the ranges and straggling of heavy ions. The difference between experimental and theoretical data do not exceed 5% in all of the cases examined. PRAL model describes the heavy ion ranges quite adequately, but overestimates the particle range straggling.
Some problems are discussed which relate to the generation of secondary radiation under the effects of heavy charged cosmic ray particles in spacecraft shielding and in biological tissue. Methods for obtaining the total and differential inelastic interaction cross sections are recommended for use in the calculation of heavy charged particle transport in the shielding. The most extensively used methods for calculating heavy charged particle passage through matter are appraised. The results of calculating cosmic ray doses in biological tissue behind shielding, which allow for the secondary particle contribution. are presented. All the calculations have been made using the set of radiation protection standards approved by the Russian State Committee for Standards. The set of standards has been verified experimentally on board satellites of the Cosmos series.
Multiplicities of various species of charged secondaries produced in inelastic interactions of 20Ne, 40Ar and 56Fe nuclei with emulsion nuclei at 0.1–0.5 GeV/nucleon have been measured. The data obtained are compared with the results for interactions of higher energy nuclei with emulsion nuclei. The dependences of the nucleus-nucleus interaction parameters on masses and energies of colliding nuclei are examined.
A method is proposed for finding the dependence of mean multiplicities of secondaries on the nucleus-collision impact parameter from the data on the total interaction ensemble. The impact parameter has been shown to completely define the mean characteristics of an individual interaction event. A difference has been found between experimental results and the data calculated in terms of the cascade-evaporation model at impact-parameter values below 3 fm.
Results of the experiments on board Cosmos-2044 (Biosatellite 9) are presented. Various nuclear track detectors (NTD) (dielectric, AgCl-based, nuclear emulsions) were used to obtain the LET spectra inside and outside the satellite. The spectra from the different NTDs have proved to be in general agreement. The results of LET spectra calculations using two different models are also presented. The resultant LET distributions are used to calculate the absorbed and equivalent doses and the orbit-averaged quality factors (QF) of the cosmic rays (CR). Absorbed dose rates inside (≈ 20 g cm-2 shielding) and outside (1 g cm-2) the spacecraft, omitting electrons, were found to be 4.8 and 8.6 mrad d-1, respectively, while the corresponding equivalent doses were 8.8 and 19.7 mrem d-1. The effects of the flight parameters on the total fluence of, and on the dose from, the CR particles are analyzed. Integral dose distributions of the detected particles are also determined. The LET values which separate absorbed and equivalent doses into 50% intervals are estimated. The CR-39 dielectric NTD is shown to detect 20–30% of the absorbed dose and 60–70% of the equivalent dose in the Cosmos-2044 orbit. The influence of solar activity phase on the magnitude of CR flux is discussed.
Nuclear tracks of cosmic ray heavy nuclei (22 ⩽ Z ⩽ 28) were identified in a multilayer assembly consisting of interlaid solid state nuclear track detectors (SSNTDs) and nuclear photoemulsions (NPEs). The assembly was exposed, as part of the scientific apparatus “Quartz”, aboard the Kosmos-1672 satellite. The nuclear tracks were identified in SSNTDs using the calibrating dependence of the etch rate ratio as a function of restricted energy loss. Those tracks which continued into emulsions were used to make internal calibrations in NPEs treated by the selective development method, enabling control of the registration threshold of nuclear emulsions. In the case of a detected particle with Z = 70 ± 5, the effectiveness of combining two types of detectors in the search for very heavy cosmic ray nuclei is demonstrated.