STATEMENT OF PROBLEM:Intraoral scanning systems have been replacing conventional workflows in dentistry as the primary method of documentation, diagnosis, and treatment. Despite their growing adoption, the accuracy of complete arch scans remains a critical challenge. PURPOSE:The aim of this clinical study was to evaluate and compare the precision and trueness of 6 current intraoral scanners (IOS) for complete arch recording using a conventional high-precision impression technique as the control group. MATERIAL AND METHODS:In 10 participants, 3 complete arch scans of the maxillary and mandibular jaws were obtained using 6 IOSs - Emerald S (EME); MEDIT i900 (MED); Primescan (PRI); Primescan 2 (PS2); Aoralscan 3 (SHI); TRIOS 5 (TRI) - and 1 conventional impression (CONV) technique. CONVs were poured and digitized using a laboratory scanner. Precision was assessed from intragroup pairwise comparison, while trueness values were calculated by comparing IOS scan data with the corresponding conventional impressions using (90_10)/2-percentile values. Statistical analyses were performed using Welch ANOVA followed by Games-Howell post hoc tests and a linear mixed-effects model (P=.05). RESULTS:Precision values ranged from 21 ±4 µm for CONV up to 82 ±38 µm for group EME. CONV showed significantly higher precision compared with all IOSs (P>.05). No significant difference was found among PRI, PS2, MED or between SHI and TRI (P>.05). Trueness values ranged from 41 ±10 µm (PRI) up to 96 ±29 µm (EME). A significant effect of scanner group on trueness was found (P<.001), but no significant differences were detected between MED and PS2, between PRI and PS2, or between SHI and TRI (P>.05). CONCLUSIONS:For dentate complete arch recordings, the standard remains conventional high-precision material. Among IOSs, significant differences concerning accuracy were found for complete arch scans, but they did not exceed 100 µm.
Intraoral scanning devices are an essential part of many digital pathways in dentistry. The aim of this first factorial comparative in-vitro study was to evaluate the influence of different jaw model configurations (model types: upper jaw [upper], upper jaw with palate [upper-pal], lower jaw [lower]) and examiners on trueness and precision of digital full-arch impressions across seven intraoral scanners. Reference models were scanned with Emerald Green [EME]; iTero 5D [ITE]; Medit i900 [MED]; Primescan [PRI]; Primescan2 [PS2]; Aoralscan 3 [SHI]; Trios 5 [TR5]. Each model type was scanned ten times (n = 10) per device, divided between two examiners with different experience levels. Trueness and precision were calculated using the (90_10)/2-percentile. Data were analyzed using a linear mixed-effects model with model type and examiner as fixed effects and scanning device as a random effect. The trueness values ranged from PRI (29.0 ± 3.7 μm, [upper-pal]) to EME (94.9 ± 18.5 μm, [lower]). Examiner and model type had no significant effect on trueness. For precision, the model type [upper-pal] showed a significant positive effect (p < 0.001), factor examiner had a significant effect (p = 0.04). The model type and examiner experience can influence the accuracy of digital impressions; however, the values observed were within clinically acceptable thresholds (< 100 μm). Including the palate in upper jaw scans can improve accuracy for certain intraoral scanners. Optimizing scanning strategies, exercising and considering jaw anatomy-especially the inclusion of the palate-may enhance scanners' accuracy.
OBJECTIVE:This in vitro study aimed to evaluate the accuracy of seven intraoral scanners (IOSs) for full-arch impressions. Correlations among three evaluation parameters summarising three-dimensional (3D) difference values were also analysed. METHODS:Custom-made complete-arch reference models were initially scanned using a reference scanner (ATOS III, Triple Scan MV60). Full-arch scans were then performed using seven IOSs (n = 20 each): Aoralscan 3, Emerald Green (EME), iTero 5D, Medit i900, Primescan (PRI), Primescan 2, and Trios 5. Conventional impressions (CONVs) (n = 20) were obtained and digitised using a laboratory scanner (inEOS X5). All data were exported as standard tessellation language files. Trueness and precision were determined using (90_10)/2-percentile values. Statistical analyses were performed using analysis of variance with Games-Howell post-hoc test and linear mixed-effects model. Correlations among absolute 80-percentile, absolute mean, and (90_10)/2-percentile were analysed using linear regression with Pearson's correlation coefficient. RESULTS:Trueness ranged from 24.5 ± 3.2 μm (CONV) to 95.0 ± 18.8 μm (EME), while precision ranged from 13.3 ± 2.6 μm (CONV) to 59.6 ± 22.4 μm (EME). CONV outperformed all IOSs. PRI showed the highest accuracy (trueness: 30.5 ± 5.3 μm, precision: 18.7 ± 5.6 μm). The evaluated parameters showed highly significant linear correlations (p < 0.001). CONCLUSIONS:All tested IOSs show full-arch deviations of <100 µm. The evaluation parameters are highly correlated, allowing for comparability. CLINICAL SIGNIFICANCE:IOSs reach clinically acceptable accuracy values for full-arch impressions. However, high-precision CONVs still achieve the highest trueness and precision for full-arch impressions.
ObjectivesTo investigate the influence of the zirconia and sintering parameters on the optical and mechanical properties.MethodsThree zirconia materials (3/4Y-TZP, 4Y-TZP, 3Y-TZP) were high-speed (HSS), speed (SS) or conventionally (CS) sintered. Disc-shaped specimens nested in 4 vertical layers of the blank were examined for grain size (GS), crystal phases (c/t’/t/m-phase), translucency (T), and biaxial flexural strength. Fracture load (FL) of three-unit fixed dental prostheses was determined initially and after thermomechanical aging. Fracture types were classified, and data statistically analyzed.Results4Y-TZP showed a higher amount of c+t’-phase and lower amount of t-phase, and higher optical and lower mechanical properties than 3Y-TZP. In all materials, T declined from Layer 1 to 4. 3/4Y-TZP showed the highest FL, followed by 3Y-TZP, while 4Y-TZP showed the lowest. In 4Y-TZP, the sintering parameters exercised a direct impact on GS and T, while mechanical properties were largely unaffected. The sintering parameters showed a varying influence on 3Y-TZP. Thermomechanical aging resulted in comparable or higher FL.Conclusion3/4Y-TZP presenting the highest FL underscores the principle of using strength-gradient multi-layer blanks to profit from high optical properties in the incisal area, while ensuring high mechanical properties in the lower areas subject to tensile forces. With all groups exceeding maximum bite forces, the examined three-unit FDPs showed promising long-term mechanical properties.
This randomized clinical trial focused on patients with thin peri-implant soft-tissue height (STH) (≤ 2.5 mm) and investigated the impact of an allogenic collagen scaffold (aCS) on supracrestal tissue height and marginal bone loss (MBL). Forty patients received bone level implants and were randomly assigned to the test group with simultaneous tissue thickening with aCS or the control group. After three months, prosthetic restoration occurred. STH measurements were taken at baseline (T0) and reopening surgery (TR), with MBL assessed at 12 months (T1). Descriptive statistics were calculated for continuous variables, and counts for categorical variables (significance level, p = 0.05). At T1, 37 patients were available. At T0, control and test groups had mean STH values of 2.3 ± 0.3 mm and 2.1 ± 0.4 mm. TR revealed mean STH values of 2.3 ± 0.2 mm (control) and 2.6 ± 0.7 mm (test), with a significant tissue thickening of 0.5 ± 0.6 mm in the test group (p < 0.03). At T1, control and test groups showed MBL mean values of 1.1 ± 0.8 mm and 1.0 ± 0.6 mm, with a moderate but significant correlation with STH thickening (-0.34), implant position (0.43), history of periodontitis (0.39), and smoking status (0.27). The use of an aCS protocol resulted in soft tissue thickening but did not reach a threshold to reliably reduce MBL compared to the control group within the study’s limitations. Peri-implant STH is crucial for maintaining peri-implant marginal bone stability. Marginal bone stability represents a crucial factor in prevention of peri-implantitis development. German register of clinical trial registration number DRKS00033290.
AIM:To assess in vitro the workflow for alveolar ridge augmentation with customised 3D printed block grafts and simultaneous computer-assisted implant planning and placement.METHODS:Twenty resin mandible models with an edentulous area and horizontal ridge defect in the region 34-36 were scanned with cone beam computed tomography (CBCT). A block graft for horizontal ridge augmentation in the region 34-36 and an implant in the position 35 were digitally planned. Twenty block grafts were 3D printed out of resin and one template for guided implant placement were stereolithographically produced. The resin block grafts were positioned onto the ridge defects and stabilised with two fixation screws each. Subsequently, one implant was inserted in the position 35 through the corresponding template for guided implant placement. Optical scans of the study models together with the fixated block graft were performed prior to and after implant placement. The scans taken after block grafting were superimposed with the virtual block grafting plan through a best-fit algorithm, and the linear deviation between the planned and the achieved block positions was calculated. The precision of the block fixation was obtained by superimposing the 20 scans taken after grafting and calculating the deviation between the corresponding resin blocks. The superimposition between the scans taken after and prior to implant placement was performed to measure a possible displacement in the block position induced by guided implant placement. The (98-2%)/2 percentile value was determined as a parameter for surface deviation.RESULTS:The mean deviation in the position of the block graft compared to the virtual plan amounted to 0.79 ± 0.13 mm. The mean deviation between the positions of the 20 block grafts measured 0.47 ± 0.2 mm, indicating a clinically acceptable precision. Guided implant placement induced a mean shift of 0.16 ± 0.06 mm in the position of the block graft.CONCLUSIONS:Within the limitations of this in vitro study, it can be concluded that customised block grafts fabricated through CBCT, computer-assisted design and 3D printing allow alveolar ridge augmentation with clinically acceptable predictability and reproducibility. Computer-assisted implant planning and placement can be performed simultaneously with computer-assisted block grafting leading to clinically non-relevant dislocation of block grafts.
Statement of problem. The use of computer-aided design and computer-aided manufacturing (CAD-CAM) technologies is widely established, with single restorations or short fixed partial dentures having similar accuracy when generated from digital scans or conventional impressions. However, research on complete-arch scanning of edentulous jaws is sparse.Purpose. The purpose of this pilot in vitro study was to compare the accuracy of a digital scan with the conventional method in a workflow generating implant-supported complete-arch prostheses and to establish whether interference from flexible soft tissue segments affects accuracy.Material and methods. An edentulous maxillary master cast containing 6 angled implant analogs was used and digitized with mounted scan bodies by using a high-precision laboratory scanner. The master cast was then scanned 10 times with 4 different intraoral scanners: TRIOS 3 with a complete-arch scanning strategy (TRI1) or implant-scanning strategy (TRI2), TRIOS Color (TRC), CEREC Omnicam (CER), and CEREC Primescan (PS). The same procedure was repeated with 4 different levels of free gingiva (G0-G3). Ten conventional impressions were obtained. Differences in implant position and direction were evaluated at the implant shoulder as mean values for trueness and interquartile range (IQR) for precision. Statistical analysis was performed by using the Kruskal-Wallis and post hoc Conover tests (cr=.05).Results. At G0, position deviations ranged from 34.8 mu m (IQR 23.0 mu m) (TRC) to 68.3 mu m (12.2 mu m) (CER). Direction deviations ranged from 0.34 degrees (IQR 0.18 degrees) (conventional) to 0.57 degrees (IQR 0.37 degrees) (TRI2). For digital systems, the position deviation ranged from 48.4 mu m (IQR 5.9 mu m) (PS) to 76.6 mu m (IQR 8.1 mu m) (TRC) at G1, from 36.3 mu m (IQR 9.3 mu m) (PS) to 79.9 mu m (IQR 36.1 mu m) (TRI1) at G2, and from 51.8 mu m (IQR 14.3 mu m) (PS) to 257.5 mu m (IQR 106.3 mu m) (TRC) at G3. The direction deviation ranged from 0.45 degrees (IQR 0.15 degrees) (CER) to 0.64 degrees (IQR 0.20 degrees) (TRC) at G1, from 0.38 degrees (IQR 0.05 degrees) (PS) to 0.925 degrees (IQR 0.09 degrees) (TRI) at G2, and from 0.44 degrees (IQR 0.07 degrees) (PS) to 1.634 degrees (IQR 1.08 degrees) (TRI) at G3. Statistical analysis revealed significant differences among the test groups for position (G0: P<.001; G1: P<.05; G2: P<.001; G3: P<.001) and direction (G0: P<.005; G1: P<.001; G2: P<.001; G3: P<.001).Conclusions. Without soft tissue interference, the accuracy of certain digital scanning systems was comparable with that of the conventional impression technique. The amount of flexible soft tissue interference affected the accuracy of the digital scans. (J Prosthet Dent 2022;128:468-78)
The purpose of this in vitro study was to compare the time efficiency of digital chairside and labside workflows with a conventional workflow for single-unit restorations. The time efficiency in this specific sense was defined as the time, which has to be spent in a dental office by a dental professional performing the relevant steps. A model with interchangeable teeth on position 36 was created. These teeth were differently prepared, responding to several clinical situations to perform single-unit restorations. Different manufacturing techniques were used: For the digital workflows, CEREC Omnicam (CER) and Trios 3 (TN/TI) were used. The conventional workflow, using a dual-arch tray impression technique, served as the control group. For the labside workflow (_L) and the conventional impression procedure (CO), the time necessary for the impressions and temporary restorations was recorded and served as operating time. The chairside workflow time was divided by the time for the entire workflow (_C) including scan, design, milling and finishing the milled restoration, and in the actual working time (_CW) leaving out the chairside milling of the restoration. Labside workflow time ranged from 9 min 27 s (CER_L) to 12 min 41 s (TI_L). Entire chairside time ranged from 43 min 35 s (CER_C) to 58 min 43 s (TI_C). Pure chairside working time ranged from 15 min 21 s (CER_CW) to 23 min 17 s (TI_CW). Conventional workflow time was 10 min 39 s (CO) on average. The digital labside workflow and the conventional workflow require a similar amount of time. The digital chairside workflow is more time consuming.
AIM:Granuloma gravidarum (GG) is a benign lesion of the soft tissue. The aim of this technical note is the volumetric assessment and follow-up 3D measurement of a GG in the anterior maxilla.MATERIALS AND METHODS:A 35-year-old female patient who was 7 months pregnant was referred due to a soft tissue tumor in the papilla of tooth 21. A biopsy verified a pyogenic granuloma gravidarum. Initial and consecutive volumeatric measurements were made with an intraoral scanner during the patient's pregnancy and until 16 months postpartum.RESULTS:The volumetric assessment showed a continuous growth of the tumor and a consecutive volume reduction 16 months postpartum. In comparison with the level of the papilla of the contralateral incisor, there was an almost complete remission at the last follow-up.CONCLUSION:Intraoral scans can serve for the volumetric assessment of soft tissue tumors of the alveolar crest. Image superimposition enables the quantification of changes in morphology. This supports clinical follow-ups and enables the quantification of clinical observations.
This study aimed to investigate whether interdental brush shape influences cleaning efficacy, by comparing a waist-shaped interdental brush (W-IDB) with a cylindrical IDB (C-IDB); both provided with the same bristle texture. Cleaning efficacy of differently shaped IDBs was measured in proximal surfaces of teeth in a split-mouth cross-over design. Twenty-eight patients abolished oral hygiene for 4 d. Line angle plaque area was scanned with an intraoral camera after use of disclosing dye in baseline and after IDB application and analyzed planimetrically. Additionally, bacterial load in the IDBs was analyzed after usage by colony forming units (cfu). A Wilcoxon signed-rank test with continuity correction was used to compare the results of the waist-shaped and the cylindrically-shaped IDBs. The waist-shaped IDBs cleaned significantly better than their cylindrically-shaped counterparts (area cleaned: 23.1% vs. 18.3%), when applied at same interdental spaces (p < 0.001). However, no significant differences were found in comparison of bacterial load on the IDBs (median cfu counts: 2.3E9 vs. 2.7E9, p = 0.93). Irrespective of bristle texture or size, IDB shape have impact on cleaning efficacy. Waist-shaped IDBs are more effective in cleaning of the line angle area than cylindrically-shaped IDBs.
In vitro studies investigating the mechanical properties of dental reconstructions use various materials to replicate prepared teeth. However, no uniform recommendation exists as to which material is most suitable for standardized testing. The purpose of this study was to identify a material that resembles human dentin in fracture load tests. Sixteen human teeth were scanned with an intraoral scanner to obtain copies of the original crown morphology and were then prepared for crowns. Replica dies of the prepared teeth including the root morphology were fabricated with a Computer-aided design and computer-aided manufacturing (CAD/CAM) system and divided into four groups: (A) reinforced composite (RC); (B) human dentin (HD); (C) polymethyl methacrylate (PM); and (D) hybrid ceramic (HC). Sixty-four feldspar ceramic crowns were designed with the biocopy mode, fabricated with a CAD/CAM system, luted on the dies, and then with the roots embedded in polymethyl methacrylate. Care was taken to position all specimens of the same morphology identically. Thermo-mechanical load cycling was performed in a chewing simulator followed by fractural loading of the crowns. A mixed effect linear model was fitted to the data, and pairwise contrasts were estimated on the marginal means and corrected for multiple testing according to Tukey (α = 0.05). The means for fracture load (N) were 2435 N (95% CI (2162, 2709)) for hybrid ceramic, 1838 N (95% CI (1565, 2112)) for reinforced composite, 1670 N (95% CI (1396, 1943)) for human tooth and 1142 N (95% CI (868, 1415)) for polymethyl methacrylate abutment materials. Post-hoc pairwise contrasts revealed a statistically significant (p < 0.05) difference among all groups except for reinforced composite and human dentin (p = 0.76). The results indicate that the mechanical properties of abutment dies play a significant role for a possible substitution of natural teeth in in vitro studies.
OBJECTIVE:Intraoral scanners (IOSs) are widely used for obtaining digital dental models directly from the patient. Additionally, improvements in IOSs are made from generation to generation. The aim of this study was to evaluate the accuracy of new and actual IOS devices for complete- and partial-arch dental impressions in an in vitro setup.MATERIALS AND METHODS:A custom maxillary complete-arch cast with teeth made from feldspar ceramic material was used as the reference cast and digitized with a reference scanner (ATOS III Triple Scan MV60). One conventional impression technique using polyvinylsiloxane (PVS) material (President) served as the control (CO), and eight different IOS devices comprising different hardware and software configurations (TRn: Trios 3; TRi: Trios 3 insane; CS: Carestream Dental CS 3600; MD: Medit i500; iT: iTero Element 2; OC4: Cerec Omnicam 4.6.1; OC5: Cerec Omnicam 5.0.0; PS: Primescan) were used to take complete-arch impressions from the reference cast. The impressions were repeated 10 times (n = 10) for each group. Conventional impressions were poured with type IV gypsum and digitized with a laboratory scanner (inEos X5). All datasets were obtained in standard tessellation language (STL) file format and cut to either complete-arch, anterior segment, or posterior segment areas for respective analysis. Values for trueness and precision for the respective areas were evaluated using a three-dimensional (3D) superimposition method with special 3D difference analysis software (GOM Inspect) using (90-10)/2 percentile values. Statistical analysis was performed using either one-way analysis of variance (ANOVA) or Kruskal-Wallis test (α = 0.05). Results are given as median and interquartile range [IQR] values in µm.RESULTS:Statistically significant differences were found between test groups for complete- and partial-arch impression methods in vitro (p < 0.05). Values ranged from 16.3 [2.8] µm (CO) up to 89.8 [26.1] µm (OC4) for in vitro trueness, and from 10.6 [3.8] µm (CO) up to 58.6 [38.4] µm (iT) for in vitro precision for the complete-arch methods. The best values for trueness of partial-arch impressions were found for the posterior segment, with 9.7 [1.2] µm for the conventional impression method (CO), and 21.9 [1.5] µm (PS) for the digital impression method.CONCLUSION:Within the limitations of this study, digital impressions obtained from specific IOSs are a valid alternative to conventional impressions for partial-arch segments. Complete-arch impressions are still challenging for IOS devices; however, certain devices were shown to be well within the required range for clinical quality. Further in vivo studies are needed to support these results.
The aim of this study was to test the fracture load of ceramic and composite three-unit full-contour fixed dental prostheses (FDPs) fabricated with additive and subtractive computer-aided design (CAD)/computer-aided manufacturing (CAM) technology. A newly developed alveolar socket replica model for a three-unit FDP replacing one molar was used in this study. Five CAD/CAM materials were used for fabrication of three-unit FDPs (each n = 12). The subtractive CAD/CAM fabrication method was used for groups BC (BRILLIANT Crios), TC (Telio CAD), EX (e.max CAD), and TZ (inCoris TZI C), and the additive method was used for group 3D (els 3D resin even stronger). FDPs were adhesively seated to the abutment dies (PANAVIA V5 system). Thermomechanical loading was performed prior to fracture testing with a universal testing machine. The data for maximum fracture load values was analyzed with one-way ANOVA and post hoc Scheffé test (α = 0.05). All FDPs survived the thermomechanical loading test. Statistically significant differences were found for the fracture load of three-unit FDPs fabricated from different CAD/CAM materials (p < 0.05). The highest mean fracture load was found for group TZ (2099.5 ± 382.1 N). Group 3D showed the lowest mean fracture load (928.9 ± 193.8 N). Group BC performed statistically significantly differently from group 3D with a mean fracture load of 1494.8 ± 214.5 N (p < 0.05). Particle-filled composite resin CAD/CAM materials showed fracture load values within the range of ceramic materials with a specific indication of use for three-unit FDPs. Particle filled composite CAD/CAM materials may offer new treatment possibilities for the CAD/CAM workflow.
OBJECTIVEThe purpose of this in vitro study was to analyze the effect of computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication and sintering procedures on the fracture load of monolithic zirconia crowns with different material thicknesses adhesively seated to methacrylate dies fabricated with stereolithography technology.METHODMonolithic zirconia crowns were fabricated from inCoris TZI C material with a chairside CAD/CAM system (CEREC MCXL) comprising three material thicknesses (0.5/1.0/1.5 mm, n=8 each). Two CAD/CAM fabrication procedures (milling, MI; grinding, GR), two chairside sintering procedures (superspeed, SS; speedfire sintering, SF), and one labside sintering procedure (classic, CL) were evaluated. In total, 144 crowns were fabricated. Restorations were adhesively seated to methacrylate dies fabricated with SLA technology. Thermomechanical cycling (TCML) was performed before fracture testing. Loading forces until fracture were registered and statistically analyzed with one-way analysis of variance (ANOVA), post hoc Scheffé test, and three-way ANOVA (α=0.05).RESULTSTest groups showed statistically significant differences (p<0.05). The highest mean value was found for 1.5-mm crowns of group GR_SF with 3678.6 ± 363.9 N. The lowest mean value was found for group 0.5-mm crowns of group MI_SF with 382.4 ± 30.7 N. There was a significant three-way interaction effect between thickness, sintering, and processing [F(4,126)=9.542; p<0.001; three-way ANOVA, significance level α=0.05].CONCLUSIONSCAD/CAM fabrication and sintering procedures influence the maximum loading force of monolithic zirconia crowns with different material thicknesses. A material thickness of 0.5 mm should be considered as a critical thickness for monolithic zirconia crown restorations.
BACKGROUND:The authors evaluated the local accuracy of intraoral scanning (IOS) systems for single-tooth preparation impressions with an in vitro setup. METHODS:The authors digitized a mandibular complete-arch model with 2 full-contour crowns and 2 multisurface inlay preparations with a highly accurate reference scanner. Teeth were made from zirconia-reinforced glass ceramic material to simulate toothlike optical behavior. Impressions were obtained either conventionally (PRESIDENT, Coltène) or digitally using the IOS systems TRIOS 3 and TRIOS 3 using insane scan speed mode (3Shape), Medit i500, Version 1.2.1 (Medit), iTero Element 2, Version 1.7 (Align Technology), CS 3600, Version 3.1.0 (Carestream Dental), CEREC Omnicam, Version 4.6.1, CEREC Omnicam, Version 5.0.0, and Primescan (Dentsply Sirona). Impressions were repeated 10 times per test group. Conventional (CO) impressions were poured with type IV gypsum and digitized with a laboratory scanner. The authors evaluated trueness and precision for preparation margin (MA) and preparation surface (SU) using 3-dimensional superimposition and 3-dimensional difference analysis method using (95% - 5%) / 2 percentile values. Statistical analysis was performed using Kruskal-Wallis test. Results were presented as median (interquartile range) values in micrometers. RESULTS:The authors found statistically significant differences for MA and SU among different test groups for both trueness and precision (P < .05). Median (interquartile range) trueness values ranged from 11.8 (2.0) μm (CO) up to 40.5 (10.9) μm (CEREC Omnicam, Version 5.0.0) for SU parameter and from 17.7 (2.6) μm (CO) up to 55.9 (15.5) μm (CEREC Omnicam, Version 5.0.0) for MA parameter. CONCLUSIONS:IOS systems differ in terms of local accuracy. Preparation MA had higher deviations compared with preparation SU for all test groups. PRACTICAL IMPLICATIONS:Trueness and precision values for both MA and SU of single-unit preparations are equal or close to CO impression for several IOS systems.
PURPOSETo assess surface characteristics and implant stability after implantoplasty performed by two different instrument sequences regarding material loss, surface roughness, and fracture load resistance. Additionally, operators' subjective experience during instrumentation and the damage to neighboring teeth were evaluated.MATERIALS AND METHODSTitanium implants were placed in the position of both first maxillary molars in models exposing 6 mm of their surface. Implantoplasty was performed in phantom heads: Exposed surfaces were instrumented with diamonds and Arkansas stones or abrasive stones and silicone polishers. Operators reported on abrasion, gloss, effectiveness, and tactility using a visual analog scale (VAS). Residual wall thickness of implants was measured on radiographs, material abrasion using three-dimensional (3D) scans, and surface roughness by contact profilometry. Maximum bending moments were measured.RESULTSResidual thickness and weight loss were comparable after both treatments (0.3 ± 0.1 and 0.25 ± 0.07 mm and 0.22 ± 0.01 g, and 0.03 ± 0.01 mm and 0.02 ± 0.01 g, respectively, P > .05). Mean surface roughness was lower (P = .0001) for the group with the silicone polishers (0.4 ± 0.2 μm) compared with the group employing diamonds (0.8 ± 0.1 μm). Maximum bending moments showed neither intergroup differences nor stability loss compared with untreated implants. The stone-and-silicone polisher group showed less abrasion (4.6 ± 2.2) and higher gloss values (8.1 ± 1.4) than the diamond-and-Arkansas group (3.1 ± 1.3 and 4.1 ± 2.1, respectively). Superficial tooth injuries at proximal neighbor teeth were common (73% and 80%).CONCLUSIONImplantoplasty did not weaken implant stability. The use of silicone polishers revealed lower surface roughness. Regarding surface smoothness, the instrumentation sequence employing silicon carbide and Arkansas stones followed by silicone polishers seems to be superior to the combination of diamond and Arkansas stones.
Indirect CAD/CAM restorations can be fabricated using both subtractive and additive CAD/CAM technology. This study investigated the fracture load of crowns fabricated from three particle-filled composite CAD/CAM materials and one 3D-printed composite material.
CLINICAL RELEVANCE::Accurate reproduction of the jaw relationship is important in many fields of dentistry. Maximum intercuspation can be registered with digital buccal scan procedures implemented in the workflow of many intraoral scanning systems. OBJECTIVE::The aim of this study was to investigate the accuracy of buccal scan procedures with intraoral scanning devices for the registration of habitual intercuspation in vivo. The hypothesis was that there is no statistically significant difference for buccal scan procedures compared to registration methods with poured model casts. METHODS AND MATERIALS::Ten individuals (full dentition, no dental rehabilitations) were subjects for five different habitual intercuspation registration methods: (CI) poured model casts, manual hand registration, buccal scan with inEOS X5; (BC) intraoral scan, buccal scan with CEREC Bluecam; (OC4.2) intraoral scan, buccal scan with CEREC Omnicam software version 4.2; (OC4.5β) intraoral scan, buccal scan with CEREC Omnicam version 4.5β; and (TR) intraoral scan, buccal scan with Trios 3. Buccal scan was repeated three times. Analysis of rotation (Rot) and translation (Trans) parameters was performed with difference analysis software (OraCheck). Statistical analysis was performed with one-way analysis of variance and the post hoc Scheffé test ( p<0.05). RESULTS::Statistical analysis showed no significant ( p>0.05) differences in terms of translation between groups CI_Trans (98.74±112.01 μm), BC_Trans (84.12±64.95 μm), OC4.2_Trans (60.70±35.08 μm), OC4.5β_Trans (68.36±36.67 μm), and TR_Trans (66.60±64.39 μm). For rotation, there were no significant differences ( p>0.05) for groups CI_Rot (0.23±0.25°), BC_Rot (0.73±0.52°), OC4.2_Rot (0.45±0.31°), OC4.5β_Rot (0.50±0.36°), and TR_Rot (0.47±0.65°). CONCLUSIONS::Intraoral scanning devices allow the reproduction of the static relationship of the maxillary and mandibular teeth with the same accuracy as registration methods with poured model casts.
OBJECTIVE To determine the accuracy (trueness and precision) of two different rapid prototyping (RP) techniques for the physical reproduction of three-dimensional (3D) digital orthodontic study casts, a comparative assessment using two 3D STL files of two different maxillary dentitions (two cases) as a reference was accomplished. MATERIALS AND METHODS Five RP replicas per case were fabricated using both stereolithography (SLA) and the PolyJet system. The 20 reproduced casts were digitized with a highly accurate reference scanner, and surface superimpositions were performed. Precision was measured by superimposing the digitized replicas within each case with themselves. Superimposing the digitized replicas with the corresponding STL reference files assessed trueness. Statistical significance between the two tested RP procedures was evaluated with independent-sample t-tests (P < .05). RESULTS The SLA and PolyJet replicas showed statistically significant differences for trueness and precision. The precision of both tested RP systems was high, with mean deviations in stereolithographic models of 23 (±6) μm and in PolyJet replicas of 46 (±13) μm. The mean deviation for trueness in stereolithographic replicas was 109 (±4) μm, while in PolyJet replicas, it was 66 (±14) μm. CONCLUSIONS Comparing the STL reference files, the PolyJet replicas showed higher trueness than the SLA models. But the precision measurements favored the SLA technique. The dimensional errors observed in this study were a maximum of 127 μm. In the present study, both types of reproduced digital orthodontic models are suitable for diagnostics and treatment planning.
STATEMENT OF PROBLEM:Three-dimensional (3D) intraoral scanning systems allow for the simultaneous acquisition of 3D information about tooth surfaces and a photorealistic view of the patient's tooth colors.AIM:The goal of this study was the in vivo comparison of a new 3D scanner with a color acquisition mode and conventional visual and digital color measurements.MATERIALS AND METHODS:The colors of 40 teeth of 20 patients were evaluated in seven ways: 1) By dentists using the Vita 3D-Master; 2) By dental technicians using the Vita 3D-Master; 3) With the 3Shape Trios device; 4) With the Vita Easyshade device; 5) With the Vita Easyshade Advance device; 6) With the SpectroShade device; and 7) With the SpectroShade Micro device. Digital measurements of Groups 3 to 7 were repeated three times for each tooth. For all groups, both the CIE Lab values and the Vita 3D-Master values were recorded. The repeatability and relative accuracy of the Vita 3D-Master values were analyzed statistically using Pearson's chi-squared test (α < 0.05). ΔE values were calculated from the CIE Lab values, which served as a basis for performing multidimensional scaling (MDS) and evaluating differences between the groups using the one-way ANOVA with post hoc Tamhane's test (α < 0.05).RESULTS:The results of the ΔE values showed that clinically relevant differences between the evaluation by dentists, dental technicians, and the intraoral scanning device (3Shape) are negligible. The intraoral 3D scanning device (Group 3) and the digital systems (Groups 4 to 7) did not differ significantly in the repeatability of color shade management. The SpectroShade Micro (Group 7) had significantly better relative accuracy than the other devices.CONCLUSIONS:The results demonstrate that intraoral scanning systems can be used to measure both tooth color and tooth surface in 3D.CLINICAL IMPLICATIONS:Intraoral optical scanning devices allow for the acquisition of accurate 3D surface data. Tooth color can be evaluated simultaneously and can be used to determine the color of restorations without requiring additional conventional color-measurement methods.