Selective retinal pigment epithelium (RPE) photodisruption requires reliable real-time feedback dosimetry (RFD) to prevent unwanted overexposure. In this study, optical coherence tomography (OCT) based RFD was investigated in ex vivo porcine eyes exposed to laser pulses of 8 µs duration (wavelength: 532 nm, exposure area: 90×90 µm², radiant exposure: 247 to 1975 mJ/µm²). For RFD, fringe washouts in time-resolved OCT M-scans (central wavelength: 870 nm, scan rate: 85 kHz) were compared to an RPE cell viability assay. Statistical analysis revealed a moderate correlation between RPE lesion size and applied treatment energy, suggesting RFD adaptation to inter- and intraindividual RPE pigmentation and ocular transmission.
Optical microsurgery confined to the retinal pigment epithelium (RPE) requires locally optimized laser parameters and reliable real-time feedback dosimetry (RFD) to prevent unwanted neuroretinal overexposure. This study aimed to compare pulses of different durations and application modes (single, ramp, burst). Moreover, optical coherence tomography (OCT)-based RFD was investigated in an ex vivo experiment, utilizing nine porcine eyes that were exposed to laser pulses of 8, 12, 16 and 20 µs duration (wavelength: 532 nm, exposure area: 90 × 90 µm2, radiant exposure: 247 to 1975 mJ/µm2). Simultaneously, time-resolved OCT M-scans were recorded (central wavelength: 870 nm, scan rate: 85 kHz) for RFD. Post irradiation, retinal changes were assessed with color fundus photography (CFP) and cross-sectional OCT B-scans. RPE cell damage was quantified via fluorescence-based cell viability assay and compared to the OCT dosimetry feedback. Our experiments indicate cumulative RPE damage for pulse bursts of 16 µs and 20 µs, whereas no cumulative effects were found for pulse durations of 8 µs and 12 µs applied in ramp mode. According to statistical analysis, OCT-RFD correctly detected RPE cell damage with 96% sensitivity and 97% specificity using pulses of 8 µs duration in ramp mode.
In the treatment of various retinal pigment epithelium (RPE) related retinal diseases, selective retina therapy (SRT) is highly demanded, as SRT intends to selectively damage the RPE while sparing the neurosensory retina (NSR) and the choroid. A gentle method for removing diseased host RPE cells is still missing regarding RPE stem cell therapy. Cell therapeutics for age -related macular degeneration are often implanted regardless of host RPE status in the target zone, which may result in RPE multilayering. Here, we study a novel laser for selective large -area RPE removal without damaging the surrounding tissue prior to RPE implantation to promote subretinal integration. Therefore, pigmented rabbit eyes were exposed to laser pulses of 8 las in duration (wavelength, 532 nm; top -hat beam profile, 223 x 223 mu m(2)). Postirradiation retinal changes were assessed with color fundus photography, fluorescein angiography, indocyanine green angiography, and optical coherence tomography (OCT). Here we present the histological outcome of four animals after laser treatment. Following euthanization, the eyes of the animals were processed for histology, sectioned in 5 mu m paraffin sections and stained with hematoxylin and eosin. Particular emphasis was given to an OCT vs light microscopy comparison. Our results reveal that RPE can be removed selectively using laser pulses of 8 mu s duration in the green spectral range without damaging the NSR. Therefore, this regime proves to be applicable in the sense of SRT.
Wafer carrier and thin wafer support during processing is key in 3D integration and advanced packaging processes. Today carrier technology can be divided based on the application and carrier wafer material. While for DRAM and other stacked memory applications silicon carriers are preferred, demanding special adhesive systems for mechanical debond, the adhesion is tuned to be high enough for processing but low enough for post process thin layer debonding. Which means the thin wafer thickness needs to be maintained typically thicker than 40µm in order to have a sufficient mechanical rigidity and support during debonding. On the other hand, UV based laser debonding decouples the adhesion during processing while the debonding is digitally triggered by UV laser irradiation and controlled destruction of engineered polymeric layer at the glass carrier surface. Despite this is the more universal debonding process, glass wafers are generally not suited for all process lines. To solve the above described difficulties, IR laser debonding has been developed enabling the combination of silicon as a carrier substrate as well as laser debonding through silicon. One solutions is in advanced packaging, where silicon can be seen as a replacement for glass wafers but still in combination with developed adhesive systems. The more impacting application, however, is the combination of IR laser release with fusion and hybrid bonding.
Optical microsurgery of the retinal pigment epithelium (RPE) requires reliable real-time dosimetry to prevent unwanted overexposure of the neuroretina. The system used in this experiment implements optical coherence tomography (OCT) to detect the intentional elimination of RPE cells. We evaluated the performance of OCT dosimetry in terms of its ability to detect RPE cell damage caused by microsecond laser pulses of varying duration. Therefore, ex-vivo porcine RPE choroid sclera explants were embedded in an artificial eye and exposed to single laser pulses of 2–20 µs duration (wavelength: 532 nm, exposure area: 120 × 120 µm2, intensity modulation factor: 1.3). Simultaneously, time-resolved OCT M-scans were recorded (central wavelength: 870 nm, scan rate: 33 kHz). Post-irradiation, RPE cell damage was quantified using a calcein-AM viability assay and compared with an OCT-dosimetry algorithm. The results of our experiments show that the OCT-based analysis successfully predicts RPE cell damage. At its optimal operating point, the algorithm achieved a sensitivity of 89% and specificity of 94% for pulses of 6 µs duration and demonstrated the ability to precisely control radiant exposure of a wide range of pulse durations towards selective real-time laser microsurgery.
A robust Ho:YAG chirped pulse amplifier with a simple dispersion management was developed for material processing applications. The amplifier produces 3.2 ps pulses centered at 2.09 mu m with energies up to 1.6 mJ. At 10 kHz repetition rate this results in 16 W of average power. Both pulse stretching and compression in the amplifier is realized within a single chirped volume Bragg grating. With the developed amplifier we study laser ablation of a gold layer through a carrier substrate and, particularly, the effect of pulse duration on the process. A balance between nonlinear effects within the carrier and interaction with the thin ablation layer makes few picosecond pulses most suitable for non-thermal ablation. Furthermore, since only a few-microjoules of pulse energy is required for de-bonding, the developed 16 W amplifier can be potentially operated at MHz repetition rates for high throughput.
Purpose Cell therapy is a promising treatment for retinal pigment epithelium (RPE)-associated eye diseases such as age-related macular degeneration. Herein, selective microsecond laser irradiation targeting RPE cells was used for minimally invasive, large-area RPE removal in preparation for delivery of retinal cell therapeutics. Methods Ten rabbit eyes were exposed to laser pulses 8, 12, 16, and 20 µs in duration (wavelength, 532 nm; top-hat beam profile, 223 × 223 µm²). Post-irradiation retinal changes were assessed with fluorescein angiography (FA), indocyanine green angiography (ICGA), and optical coherence tomography (OCT). RPE viability was evaluated with an angiographic probit model. Following vitrectomy, a subretinal injection of balanced salt solution was performed over a lasered (maximum 13.6 mm2) and untreated control area. Bleb retinal detachment (bRD) morphology was then evaluated by intraoperative OCT. Results Within 1 hour after irradiation, laser lesions showed FA and ICGA leakage. OCT revealed that large-area laser damage was limited to the RPE. The angiographic median effective dose irradiation thresholds (ED50) were 45 µJ (90 mJ/cm2) at 8 µs, 52 µJ (104 mJ/cm2) at 12 µs, 59 µJ (118 mJ/cm2) at 16 µs, and 71 µJ (142 mJ/cm2) at 20 µs. Subretinal injection over the lasered area resulted in a controlled, shallow bRD rise, whereas control blebs were convex in shape, with less predictable spread. Conclusions Large-area, laser-based removal of host RPE without visible photoreceptor damage is possible and facilitates surgical retinal detachment. Translational Relevance Selective microsecond laser-based, large-area RPE removal prior to retinal cell therapy may reduce iatrogenic trauma.
Purpose: To evaluate the feasibility and safety of a coaxial dual-wavelength optical coherence tomography (OCT) device (marked as Hydra-OCT). Methods: Healthy participants without ocular pathology underwent retinal imaging using the Hydra-OCT allowing for simultaneous measurement of retinal scanning of 840 and 1,072 nm wavelength. Before and after measurement, best-corrected visual acuity and patients’ comfort were assessed. Representative OCT images from both wavelengths were compared by 5 independent graders using a subjective grading scheme. Results: A total of 30 eyes of 30 participants (8 females and 22 males) with a mean age of 26.5 years (range from 19 to 55 years) were included. Dual-wavelength image acquisition was made possible in each subject. The participant’s effort and comfort assessment using the Hydra-OCT imaging revealed an equivalent value as compared to the commercially available OCT machine. No adverse events were reported, and visual acuity was not altered by the Hydra-OCT. Imaging between the systems was comparable. Conclusions: This study provides evidence for the feasibility and safety of a coaxial dual-wavelength OCT imaging method under real-life conditions. The novel Hydra-OCT imaging device may offer additional insights into the pathology of retinal and choroidal diseases.
We study an effect of pulse duration of 2.09-pm laser on the laser de-bonding of gold from silicon wafers. Developed picosecond Ho:YAG laser with a simple dispersion management is found to be optimal for the process.
Monitoring subtle choroidal thickness changes in the human eye delivers insight into the pathogenesis of various ocular diseases such as myopia and helps planning their treatment. However, a thorough evaluation of detection-performance is challenging as a ground truth for comparison is not available. Alternatively, an artificial ground truth can be generated by averaging the manual expert segmentations. This makes the ground truth very sensitive to ambiguities due to different interpretations by the experts. In order to circumvent this limitation, we present a novel validation approach that operates independently from a ground truth and is uniquely based on the common agreement between algorithm and experts. Utilizing an appropriate index, we compare the joint agreement of several raters with the algorithm and validate it against manual expert segmentation. To illustrate this, we conduct an observational study and evaluate the results obtained using our previously published registration-based method. In addition, we present an adapted state-of-the-art evaluation method, where a paired t-test is carried out after leaving out the results of one expert at the time. Automated and manual detection were performed on a dataset of 90 OCT 3D-volume stack pairs of healthy subjects between 8 and 18 years of age from Asian urban regions with a high prevalence of myopia.
Robust 2.09-μm, 3.2-ps, 1.6-mJ, 16-W Ho:YAG CPA system with a simple dispersion and bandwidth management is developed and employed for material-processing. Successful de-bonding of aluminum through silicon wafer by 2-μm picosecond pulses is demonstrated.
Selective retina therapy (SRT) is a short pulse (mu s-regime) alternative to conventional laser photocoagulation (LPC) for treatment of retinal diseases. LPC leads to collateral damage of retinal layers adjacent to the retinal pigment epithelium (RPE), including healthy, non-regenerative photoreceptors due to the high thermal load, whereas in SRT, RPE cells are destroyed by microbubbles without damaging the neuronal retina. A novel experimental SRT laser operating at 532 nm wavelength can deliver 2 - 20 mu s pulse sequences. Its tight integration into an upgraded diagnostic SPECTRALIS system combines beam control for treatment planning with real-time optical coherence tomography (OCT) overexposure protection of the photoreceptors. This "Spectralis Centaurus" system, was built and preliminary tested on porcine ex-vivo samples, reaching an unprecedented accuracy with unique planning and follow-up capabilities for upcoming clinical cellular level micro-surgery. The combination of OCT with SRT selectively limits cell death to the RPE by precisely controlling energy deposition while optically monitoring tissue response.
Selective retina therapy and optical coherence tomography have been combined to monitor laser-tissue interaction in real-time. An ex-vivo study of porcine eyes unveils mechanisms that enable automated and accurate dose-control during laser-therapy.
Ocular optical coherence tomography at the wavelengths ranges of 850 and 1060 nm have been integrated with a confocal scanning laser ophthalmoscope eye-tracker as a clinical commercial-class system. Collinear optics enables an exact overlap of the different channels to produce precisely overlapping depth-scans for evaluating the similarities and differences between the wavelengths to extract additional physiologic information. A reliable segmentation algorithm utilizing Graphcuts has been implemented and applied to automatically extract retinal and choroidal shape in cross-sections and volumes. The device has been tested in normals and pathologies including a cross-sectional and longitudinal study of myopia progress and control with a duplicate instrument in Asian children.