Background:Computerised decision support systems (CDSS) are widely used by nurses and allied health professionals but their effect on clinical performance and patient outcomes is uncertain. Objectives:Evaluate the effects of clinical decision support systems use on nurses', midwives' and allied health professionals' performance and patient outcomes and sense-check the results with developers and users. Eligibility criteria:Comparative studies (randomised controlled trials (RCTs), non-randomised trials, controlled before-and-after (CBA) studies, interrupted time series (ITS) and repeated measures studies comparing) of CDSS versus usual care from nurses, midwives or other allied health professionals. Information sources:Nineteen bibliographic databases searched October 2019 and February 2021. Risk of bias:Assessed using structured risk of bias guidelines; almost all included studies were at high risk of bias. Synthesis of results:Heterogeneity between interventions and outcomes necessitated narrative synthesis and grouping by: similarity in focus or CDSS-type, targeted health professionals, patient group, outcomes reported and study design. Included studies:Of 36,106 initial records, 262 studies were assessed for eligibility, with 35 included: 28 RCTs (80%), 3 CBA studies (8.6%), 3 ITS (8.6%) and 1 non-randomised trial, a total of 1318 health professionals and 67,595 patient participants. Few studies were multi-site and most focused on decision-making by nurses (71%) or paramedics (5.7%). Standalone, computer-based CDSS featured in 88.7% of the studies; only 8.6% of the studies involved 'smart' mobile or handheld technology. Care processes - including adherence to guidance - were positively influenced in 47% of the measures adopted. For example, nurses' adherence to hand disinfection guidance, insulin dosing, on-time blood sampling, and documenting care were improved if they used CDSS. Patient care outcomes were statistically - if not always clinically - significantly improved in 40.7% of indicators. For example, lower numbers of falls and pressure ulcers, better glycaemic control, screening of malnutrition and obesity, and accurate triaging were features of professionals using CDSS compared to those who were not. Evidence limitations:Allied health professionals (AHPs) were underrepresented compared to nurses; systems, studies and outcomes were heterogeneous, preventing statistical aggregation; very wide confidence intervals around effects meant clinical significance was questionable; decision and implementation theory that would have helped interpret effects - including null effects - was largely absent; economic data were scant and diverse, preventing estimation of overall cost-effectiveness. Interpretation:CDSS can positively influence selected aspects of nurses', midwives' and AHPs' performance and care outcomes. Comparative research is generally of low quality and outcomes wide ranging and heterogeneous. After more than a decade of synthesised research into CDSS in healthcare professions other than medicine, the effect on processes and outcomes remains uncertain. Higher-quality, theoretically informed, evaluative research that addresses the economics of CDSS development and implementation is still required. Future work:Developing nursing CDSS and primary research evaluation. Funding:This project was funded by the National Institute for Health and Care Research (NIHR) Health and Social Care Delivery Research programme and will be published in Health and Social Care Delivery Research; 2023. See the NIHR Journals Library website for further project information. Registration:PROSPERO 1 [number: CRD42019147773].
Background For people at high risk of lung cancer, low-dose computed tomography (LDCT) is proposed as a method to reduce mortality. Methods Our objective was to estimate the effect of LDCT lung cancer screening on mortality in high-risk populations. A systematic review of randomised controlled trials (RCTs) comparing LDCT screening programmes with usual care (no screening) or other imaging screening programme (such as chest X-ray (CXR)) was conducted. RCTs of CXR screening were additionally included in the network meta-analyses. Bibliographic sources including MEDLINE, Embase, Web of Science and the Cochrane Library were searched to January 2017, and then further extended to November 2021. All key review steps were done by two persons. Quality assessment used the Cochrane Risk of Bias tool. Meta-analyses were performed. Results Nine RCTs, with up to 12.3 years of follow-up from randomisation, were included in the direct meta-analysis, which showed that LDCT screening was associated with a statistically significant decrease in lung cancer mortality (pooled relative risk (RR) 0.86, 95% confidence interval [CI] 0.77 to 0.96). There was a statistically non-significant decrease in all-cause mortality (pooled RR 0.98, 95% CI 0.95 to 1.01). The statistical heterogeneity for both outcomes was minimal. Network meta-analysis including the nine RCTs in the direct meta-analysis plus two further RCTs comparing CXR with usual care confirmed the size of the effect of LDCT on lung cancer mortality and that this was very similar irrespective of whether the comparator was usual care or CXR screening. Conclusions LDCT screening is effective in reducing lung cancer mortality in high-risk populations. The uncertainty of its effect on lung cancer mortality observed in 2018 has been much reduced with new trial results and updates to existing trials, emphasising the importance of updating systematic reviews. Although there are still a number of RCTs unreported or in progress, we predict that further evolution of summary mortality estimates is unlikely. The focus for debate now moves to resolving uncertainty about the cost-effectiveness of LDCT screening taking into account the balance between benefits and harms which occur in all screening programmes.
IntroductionPatients with severe rheumatoid arthritis (RA) disease may be treated with tumor necrosis factor (TNF)-α inhibitors. However, their efficacy is reduced by the presence of anti-drug antibodies. The objective of this HTA was to conduct a systematic review to investigate the effectiveness of using enzyme-linked immunosorbent assay (ELISA) tests (Promonitor, IDKmonitor, LISA-TRACKER, RIDASCREEN, MabTrack, and Sanquin Diagnostic Services) to measure levels of the drug and anti-drug antibodies for monitoring response to TNF-α inhibitors in patients with RA.MethodsA range of bibliographic databases including MEDLINE, EMBASE and CENTRAL were searched from inception to November 2018. Studies were eligible for inclusion if they investigated ELISA tests in RA patients receiving treatment with a TNF-α inhibitor who had achieved the treatment target (remission or low disease activity [LDA]) or experienced a primary or a secondary non-response. The tests must compare with standard care where treatment decisions are based on clinical judgements and monitoring using a composite score such as the disease activity score 28 joints (DAS28). Risk of bias was assessed using the Cochrane (ROBINS-1) tool for non-randomized studies.ResultsTwo studies were included. One non-randomized controlled trial (non-RCT) compared standard care with therapeutic drug monitoring using Promonitor test kits in RA patients in remission/LDA receiving adalimumab, and a historically controlled study investigated Sanquin ELISA kits. The non-RCT study showed that there was a non-significant reduction in the risk of flare in the intervention group compared with the control group. Patients’ health-related quality of life outcomes were higher in the intervention group at all visits compared with the control group. However, this study had serious limitations because analyses were not performed using an intention-to-treat approach. The historically controlled study did not provide valid evidence on whether ELISA-based monitoring is clinically effective.ConclusionsThere is only limited, poor evidence available. There are considerable uncertainties on the effectiveness of using ELISA tests for monitoring response to TNF-α inhibitors in RA. Further controlled trials are required.
Objective Computerised clinical decision support systems (CDSS) are an increasingly important part of nurse and allied health professional (AHP) roles in delivering healthcare. The impact of these technologies on these health professionals’ performance and patient outcomes has not been systematically reviewed. We aimed to conduct a systematic review to investigate this. Materials and methods The following bibliographic databases and grey literature sources were searched by an experienced Information Professional for published and unpublished research from inception to February 2021 without language restrictions: MEDLINE (Ovid), Embase Classic+Embase (Ovid), PsycINFO (Ovid), HMIC (Ovid), AMED (Allied and Complementary Medicine) (Ovid), CINAHL (EBSCO), Cochrane Central Register of Controlled Trials (Wiley), Cochrane Database of Systematic Reviews (Wiley), Social Sciences Citation Index Expanded (Clarivate), ProQuest Dissertations & Theses Abstracts & Index, ProQuest ASSIA (Applied Social Science Index and Abstract), Clinical Trials.gov, WHO International Clinical Trials Registry (ICTRP), Health Services Research Projects in Progress (HSRProj), OpenClinical(www.OpenClinical.org), OpenGrey (www.opengrey.eu), Health.IT.gov, Agency for Healthcare Research and Quality (www.ahrq.gov). Any comparative research studies comparing CDSS with usual care were eligible for inclusion. Results A total of 36 106 non-duplicate records were identified. Of 35 included studies: 28 were randomised trials, three controlled-before-and-after studies, three interrupted-time-series and one non-randomised trial. There were ~1318 health professionals and ~67 595 patient participants in the studies. Most studies focused on nurse decision-makers (71%) or paramedics (5.7%). CDSS as a standalone Personal Computer/LAPTOP-technology was a feature of 88.7% of the studies; only 8.6% of the studies involved ‘smart’ mobile/handheld-technology. Discussion CDSS impacted 38% of the outcome measures used positively. Care processes were better in 47% of the measures adopted; examples included, nurses’ adherence to hand disinfection guidance, insulin dosing, on-time blood sampling and documenting care. Patient care outcomes in 40.7% of indicators were better; examples included, lower numbers of falls and pressure ulcers, better glycaemic control, screening of malnutrition and obesity and triaging appropriateness. Conclusion CDSS may have a positive impact on selected aspects of nurses’ and AHPs’ performance and care outcomes. However, comparative research is generally low quality, with a wide range of heterogeneous outcomes. After more than 13 years of synthesised research into CDSS in healthcare professions other than medicine, the need for better quality evaluative research remains as pressing.
BACKGROUND:Rheumatoid arthritis is a chronic autoimmune disease that primarily causes inflammation, pain and stiffness in the joints. People with severe disease may be treated with biological disease-modifying anti-rheumatic drugs, including tumour necrosis factor-α inhibitors, but the efficacy of these drugs is hampered by the presence of anti-drug antibodies. Monitoring the response to these treatments typically involves clinical assessment using response criteria, such as Disease Activity Score in 28 joints or European League Against Rheumatism. Enzyme-linked immunosorbent assays can also be used to measure drug and antibody levels in the blood. These tests may inform whether or not adjustments to treatment are required or help clinicians to understand the reasons for treatment non-response or a loss of response. METHODS:Systematic reviews were conducted to identify studies reporting on the clinical effectiveness and cost-effectiveness of using enzyme-linked immunosorbent assays to measure drug and anti-drug antibody levels to monitor the response to tumour necrosis factor-α inhibitors [adalimumab (Humira®; AbbVie, Inc., North Chicago, IL, USA), etanercept (Enbrel®; Pfizer, Inc., New York, NY, USA), infliximab (Remicade®, Merck Sharp & Dohme Limited, Hoddesdon, UK), certolizumab pegol (Cimzia®; UCB Pharma Limited, Slough, UK) and golimumab (Simponi®; Merck Sharp & Dohme Limited)] in people with rheumatoid arthritis who had either achieved treatment target (remission or low disease activity) or shown primary or secondary non-response to treatment. A range of bibliographic databases, including MEDLINE, EMBASE and CENTRAL (Cochrane Central Register of Controlled Trials), were searched from inception to November 2018. The risk of bias was assessed using the Cochrane ROBINS-1 (Risk Of Bias In Non-randomised Studies - of Interventions) tool for non-randomised studies, with adaptations as appropriate. Threshold and cost-utility analyses that were based on a decision tree model were conducted to estimate the economic outcomes of adding therapeutic drug monitoring to standard care. The costs and resource use were considered from the perspective of the NHS and Personal Social Services. No discounting was applied to the costs and effects owing to the short-term time horizon of 18 months that was adopted in the economic analysis. The impact on the results of variations in testing and treatment strategies was explored in numerous clinically plausible sensitivity analyses. RESULTS:Two studies were identified: (1) a non-randomised controlled trial, INGEBIO, that compared standard care with therapeutic drug monitoring using Promonitor® assays [Progenika Biopharma SA (a Grifols-Progenika company), Derio, Spain] in Spanish patients receiving adalimumab who had achieved remission or low disease activity; and (2) a historical control study. The economic analyses were informed by INGEBIO. Different outcomes from INGEBIO produced inconsistent results in both threshold and cost-utility analyses. The cost-effectiveness of therapeutic drug monitoring varied, from the intervention being dominant to the incremental cost-effectiveness ratio of £164,009 per quality-adjusted life-year gained. However, when the frequency of testing was assumed to be once per year and the cost of phlebotomy appointments was excluded, therapeutic drug monitoring dominated standard care. LIMITATIONS:There is limited relevant research evidence and much uncertainty about the clinical effectiveness and cost-effectiveness of using enzyme-linked immunosorbent assay-based testing for therapeutic drug monitoring in rheumatoid arthritis patients. INGEBIO had serious limitations in relation to the National Institute for Health and Care Excellence scope: only one-third of participants had rheumatoid arthritis, the analyses were mostly not by intention to treat and the follow-up was 18 months only. Moreover, the outcomes might not be generalisable to the NHS. CONCLUSIONS:Based on the available evidence, no firm conclusions could be made about the cost-effectiveness of therapeutic drug monitoring in England and Wales. FUTURE WORK:Further controlled trials are required to assess the impact of using enzyme-linked immunosorbent assays for monitoring the anti-tumour necrosis factors in people with rheumatoid arthritis. STUDY REGISTRATION:This study is registered as PROSPERO CRD42018105195. FUNDING:This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 8. See the NIHR Journals Library website for further project information.
Diagnosis of lung cancer frequently occurs in its later stages. Low-dose computed tomography (LDCT) could detect lung cancer early. Our objective was to estimate the effect of LDCT lung cancer screening on mortality in high-risk populations. A systematic review of randomised controlled trials (RCTs) comparing LDCT screening programmes with usual care (no screening) or other imaging screening programme (such as chest X-ray (CXR)) was conducted. RCTs of CXR screening were additionally included in the network meta-analysis. Bibliographic sources including MEDLINE, Embase, Web of Science and the Cochrane Library were searched to January 2017. All key review steps were done by two persons. Quality assessment used the Cochrane Risk of Bias tool. Meta-analyses were performed. Four RCTs were included. More will provide data in the future. Meta-analysis demonstrated that LDCT screening with up to 9.80 years of follow-up was associated with a statistically non-significant decrease in lung cancer mortality (pooled relative risk (RR) 0.94, 95% confidence interval (CI) 0.74 to 1.19; p = 0.62). There was a statistically non-significant increase in all-cause mortality. Given the considerable heterogeneity for both outcomes, the results should be treated with caution. Network meta-analysis including the four original RCTs plus two further RCTs assessed the relative effectiveness of LDCT, CXR and usual care. The results showed that in terms of lung cancer mortality reduction LDCT was ranked as the best screening strategy, CXR screening as the worst strategy and usual care intermediate. LDCT screening may be effective in reducing lung cancer mortality but there is considerable uncertainty: the largest of the RCTs compared LDCT with CXR screening rather than no screening; there is imprecision of the estimates; and there is important heterogeneity between the included study results. The uncertainty about the effect on all-cause mortality is even greater. Maturing trials may resolve the uncertainty.
Background: High-throughput non-invasive prenatal testing (NIPT) for fetal Rhesus D (RhD) status could avoid unnecessary treatment with anti-D immunoglobulin for RhD-negative women found to be carrying an RhD-negative fetus. We aimed to assess the diagnostic accuracy of high-throughput NIPT for fetal RhD status in RhD-negative women not known to be sensitized to the RhD antigen, by performing a systematic review and meta-analysis. Methods: Prospective cohort studies of high-throughput NIPT used to determine fetal RhD status were included. The eligible population were pregnant women who were RhD negative and not known to be sensitized to RhD antigen. The index test was high-throughput, NIPT cell-free fetal DNA tests of maternal plasma used to determine fetal RhD status. The reference standard considered was serologic cord blood testing at birth. Databases including MEDLINE, EMBASE, and Science Citation Index were searched up to February 2016. Two reviewers independently screened titles and abstracts and assessed full texts identified as potentially relevant. Risk of bias was assessed using QUADAS-2. The bivariate and hierarchical summary receiver-operating characteristic (HSROC) models were fitted to calculate summary estimates of sensitivity, specificity, false positive and false negative rates, and the associated 95% confidence intervals (CIs). Results: A total of 3921 references records were identified through electronic searches. Eight studies were included in the systematic review. Six studies were judged to be at low risk of bias. The HSROC models demonstrated high diagnostic performance of high-throughput NIPT testing for women tested at or after 11 weeks gestation. In the primary analysis for diagnostic accuracy, women with an inconclusive test result were treated as having tested positive. The false negative rate (incorrectly classed as RhD negative) was 0.34% (95% CI 0.15 to 0.76) and the false positive rate (incorrectly classed as RhD positive) was 3.86% (95% CI 2.54 to 5.82). There was limited evidence for non-white women and multiple pregnancies. Conclusions: High-throughput NIPT is sufficiently accurate to detect fetal RhD status in RhD-negative women and would considerably reduce unnecessary treatment with routine anti-D immunoglobulin. The applicability of these findings to non-white women and women with multiple pregnancies is uncertain.
Background: High-throughput non-invasive prenatal testing (NIPT) for fetal rhesus (D antigen) (RhD) status could avoid unnecessary treatment with routine anti-D immunoglobulin for RhD-negative women carrying a RhD-negative fetus, although this may lead to an increased risk of RhD sensitisations. Objectives: To systematically review the evidence on the diagnostic accuracy, clinical effectiveness and implementation of high-throughput NIPT and to develop a cost-effectiveness model. Methods: We searched MEDLINE and other databases, from inception to February 2016, for studies of high-throughput NIPT free-cell fetal deoxyribonucleic acid (DNA) tests of maternal plasma to determine fetal RhD status in RhD-negative pregnant women who were not known to be sensitised to the RhD antigen. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) and A Cochrane Risk of Bias Assessment Tool: for Non-Randomised Studies of Interventions (ACROBAT-NRSI). Summary estimates of false-positive rates (FPRs) and false-negative rates (FNRs) were calculated using bivariate models. Clinical effectiveness evidence was used to conduct a simulation study. We developed a de novo probabilistic decision tree-based cohort model that considered four alternative ways in which the results of NIPT could guide the use of anti-D immunoglobulin antenatally and post partum. Sensitivity analyses (SAs) were conducted to address key uncertainties and model assumptions. Results: Eight studies were included in the diagnostic accuracy review, seven studies were included in the clinical effectiveness review and 12 studies were included in the review of implementation. Meta-analyses included women mostly at or post 11 weeks’ gestation. The pooled FNR (women at risk of sensitisation) was 0.34% [95% confidence interval (CI) 0.15% to 0.76%] and the pooled FPR (women needlessly receiving anti-D) was 3.86% (95% CI 2.54% to 5.82%). SAs did not materially alter the overall results. Data on clinical outcomes, including sensitisation rates, were limited. Our simulation suggests that NIPT could substantially reduce unnecessary use of antenatal anti-D with only a small increase in the risk of sensitisation. All large implementation studies suggested that large-scale implementation of high-throughput NIPT was feasible. Seven cost-effectiveness studies were included in the review, which found that the potential for the use of NIPT to produce cost savings was dependent on the cost of the test. Our de novo model suggested that high-throughput NIPT is likely to be cost saving compared with the current practice of providing routine antenatal anti-D prophylaxis to all women who are RhD negative. The extent of the cost saving appeared to be sufficient to outweigh the small increase in sensitisations. However, the magnitude of the cost saving is highly sensitive to the cost of NIPT itself. Limitations: There was very limited evidence relating to the clinical effectiveness of high-throughput NIPT, with no evidence on potential adverse effects. The generalisability of the findings to non-white women and multiple pregnancies is unclear. Conclusions: High-throughput NIPT is sufficiently accurate to detect fetal RhD status in RhD-negative women from 11 weeks’ gestation and would considerably reduce unnecessary treatment with routine anti-D immunoglobulin, potentially resulting in cost savings of between £485,000 and £671,000 per 100,000 pregnancies if the cost of implementing NIPT is in line with that reflected in this evaluation. Future work: Further research on the diagnostic accuracy of NIPT in non-white women is needed. Study registration: This study is registered as PROSPERO CRD42015029497. Funding: The National Institute for Health Research Health Technology Assessment programme.
ObjectiveTo evaluate the cost‐effectiveness of high‐throughput, non‐invasive prenatal testing (HT‐NIPT) for fetal Rhesus D (RhD) genotype to guide antenatal prophylaxis with anti‐D immunoglobulin compared with routine antenatal anti‐D immunoglobulin prophylaxis (RAADP).DesignCost‐effectiveness decision‐analytic modelling.SettingPrimary care.ParticipantsA simulated population of 100 000 RhD‐negative women not known to be sensitised to the RhD antigen.MethodsA decision tree model was used to characterise the antenatal care pathway in England and the long‐term consequences of sensitisation events. The diagnostic accuracy of HT‐NIPT was derived from a systematic review and bivariate meta‐analysis; estimates of other inputs were derived from relevant literature sources and databases. Women in whom the HT‐NIPT was positive or inconclusive continued to receive RAADP, whereas women with a negative result received none. Five alternative strategies in which the use of HT‐NIPT may affect the existing postpartum care pathway were considered.Main outcome measuresCosts expressed in 2015GBP and impact on health outcomes expressed in terms of quality‐adjusted life‐years over a lifetime.ResultsThe results suggested that HT‐NIPT appears cost saving but also less effective than current practice, irrespective of the postpartum strategy evaluated. A postpartum strategy in which inconclusive test results are distinguished from positive results performed best. HT‐NIPT is only cost‐effective when the overall test cost is £26.60 or less.ConclusionsHT‐NIPT would reduce unnecessary treatment with routine anti‐D immunoglobulin and is cost saving when compared with current practice. The extent of any savings and cost‐effectiveness is sensitive to the overall test cost.Tweetable abstractHT‐NIPT is cost saving compared with providing anti‐D to all RhD‐negative pregnant women.
Background Diagnosis of lung cancer frequently occurs in its later stages. Low-dose computed tomography (LDCT) could detect lung cancer early. Objectives To estimate the clinical effectiveness and cost-effectiveness of LDCT lung cancer screening in high-risk populations. Data sources Bibliographic sources included MEDLINE, EMBASE, Web of Science and The Cochrane Library. Methods Clinical effectiveness – a systematic review of randomised controlled trials (RCTs) comparing LDCT screening programmes with usual care (no screening) or other imaging screening programmes [such as chest X-ray (CXR)] was conducted. Bibliographic sources included MEDLINE, EMBASE, Web of Science and The Cochrane Library. Meta-analyses, including network meta-analyses, were performed. Cost-effectiveness – an independent economic model employing discrete event simulation and using a natural history model calibrated to results from a large RCT was developed. There were 12 different population eligibility criteria and four intervention frequencies [(1) single screen, (2) triple screen, (3) annual screening and (4) biennial screening] and a no-screening control arm. Results Clinical effectiveness – 12 RCTs were included, four of which currently contribute evidence on mortality. Meta-analysis of these demonstrated that LDCT, with ≤ 9.80 years of follow-up, was associated with a non-statistically significant decrease in lung cancer mortality (pooled relative risk 0.94, 95% confidence interval 0.74 to 1.19). The findings also showed that LDCT screening demonstrated a non-statistically significant increase in all-cause mortality. Given the considerable heterogeneity detected between studies for both outcomes, the results should be treated with caution. Network meta-analysis, including six RCTs, was performed to assess the relative clinical effectiveness of LDCT, CXR and usual care. The results showed that LDCT was ranked as the best screening strategy in terms of lung cancer mortality reduction. CXR had a 99.7% probability of being the worst intervention and usual care was ranked second. Cost-effectiveness – screening programmes are predicted to be more effective than no screening, reduce lung cancer mortality and result in more lung cancer diagnoses. Screening programmes also increase costs. Screening for lung cancer is unlikely to be cost-effective at a threshold of £20,000/quality-adjusted life-year (QALY), but may be cost-effective at a threshold of £30,000/QALY. The incremental cost-effectiveness ratio for a single screen in smokers aged 60–75 years with at least a 3% risk of lung cancer is £28,169 per QALY. Sensitivity and scenario analyses were conducted. Screening was only cost-effective at a threshold of £20,000/QALY in only a minority of analyses. Limitations Clinical effectiveness – the largest of the included RCTs compared LDCT with CXR screening rather than no screening. Cost-effectiveness – a representative cost to the NHS of lung cancer has not been recently estimated according to key variables such as stage at diagnosis. Certain costs associated with running a screening programme have not been included. Conclusions LDCT screening may be clinically effective in reducing lung cancer mortality, but there is considerable uncertainty. There is evidence that a single round of screening could be considered cost-effective at conventional thresholds, but there is significant uncertainty about the effect on costs and the magnitude of benefits. Future work Clinical effectiveness and cost-effectiveness estimates should be updated with the anticipated results from several ongoing RCTs [particularly the NEderlands Leuvens Longkanker Screenings ONderzoek (NELSON) screening trial]. Study registration This study is registered as PROSPERO CRD42016048530. Funding The National Institute for Health Research Health Technology Assessment programme.
Objective The Brunswik lens model typically represents a judge's accuracy using parameters derived from linear regression. This is not optimal if the judgment or the ecological criterion is dichotomous. Alternative approaches, modeling dichotomies using logistic regression, or linearizing judgments with confidence ratings, have not been compared with the same data. Method Four techniques for deriving lens model equation parameters were compared: 1) linear and 2) logistic regression applied to dichotomous patient outcomes and judgments; 3) linear regression with confidence-adjusted judgments but dichotomous patient outcomes; and 4) a hybrid with a linear model of the confidence-adjusted judgments and a logistic model of the patient outcomes. Results Judgment accuracy (ra) was slightly higher with confidence adjustment of the categorical judgments. The logistic lens model accounted for a higher proportion of ra than the linear lens model; the confident-linear and hybrid lens models were intermediate. For up to a quarter of participants, different methods identified different cues as most important. Display condition differences in achievement ra and in lens model components are similar with all lens model methods. Conclusion Each of the three alternative lens model equation methods improves on the linear lens model equation's decomposition of the accuracy of dichotomous judgments. Confidence adjustment improves achievement although it requires additional work from the subjects. The logistic lens model equation explains the highest proportion of achievement, but with a small stimulus set it is more vulnerable to cue intercorrelations than either the linear or the confident linear lens model equation.
BACKGROUND:Nurses' risk assessments of patients at risk of deterioration are sometimes suboptimal. Advances in clinical simulation mean higher quality information can be used as an alternative to traditional paper-based approaches as a means of improving judgement. This paper tests the hypothesis that nurses' judgement strategies and policies change as the quality of information used by nurses in simulation changes.METHODS:Sixty-three student nurses and 34 experienced viewed 25 paper-case based and 25 clinically simulated scenarios, derived from real cases, and judged whether the (simulated) patient was at 'risk' of acute deterioration. Criteria of judgement "correctness" came from the same real cases. Information relative weights were calculated to examine judgement policies of individual nurses. Group comparisons of nurses and students under both paper and clinical simulation conditions were undertaken using non parametric statistical tests. Judgment policies were also compared to the ecological statistical model. Cumulative relative weights were calculated to assess how much information nurses used when making judgements. Receiver operating characteristic (ROC) curves were generated to examine predictive accuracy amongst the nurses.RESULTS:There were significant variations between nurses' judgement policies and those optimal policies determined by the ecological model. Nurses significantly underused the cues of consciousness level, respiration rate, and systolic blood pressure than the ecological model requires. However, in clinical simulations, they tended to make appropriate use of heart rate, with non-significant difference in the relative weights of heart rate between clinical simulations and the ecological model. Experienced nurses paid substantially more attention to respiration rate in the simulated setting compared to paper cases, while students maintained a similar attentive level to this cue. This led to a non-significant difference in relative weights of respiration rate between experienced nurses and students.CONCLUSIONS:Improving the quality of information by clinical simulations significantly impacted on nurses' judgement policies of risk assessments. Nurses' judgement strategies also varied with the increased years of experience. Such variations in processing clinical information may contribute to nurses' suboptimal judgements in clinical practice. Constructing predictive models of common judgement situations, and increasing nurses' awareness of information weightings in such models may help improve judgements made by nurses.
BACKGROUND It is uncertain which simple measures of childhood obesity are best for predicting future obesity-related health problems and the persistence of obesity into adolescence and adulthood. OBJECTIVES To investigate the ability of simple measures, such as body mass index (BMI), to predict the persistence of obesity from childhood into adulthood and to predict obesity-related adult morbidities. To investigate how accurately simple measures diagnose obesity in children, and how acceptable these measures are to children, carers and health professionals. DATA SOURCES Multiple sources including MEDLINE, EMBASE and The Cochrane Library were searched from 2008 to 2013. METHODS Systematic reviews and a meta-analysis were carried out of large cohort studies on the association between childhood obesity and adult obesity; the association between childhood obesity and obesity-related morbidities in adulthood; and the diagnostic accuracy of simple childhood obesity measures. Study quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) and a modified version of the Quality in Prognosis Studies (QUIPS) tool. A systematic review and an elicitation exercise were conducted on the acceptability of the simple measures. RESULTS Thirty-seven studies (22 cohorts) were included in the review of prediction of adult morbidities. Twenty-three studies (16 cohorts) were included in the tracking review. All studies included BMI. There were very few studies of other measures. There was a strong positive association between high childhood BMI and adult obesity [odds ratio 5.21, 95% confidence interval (CI) 4.50 to 6.02]. A positive association was found between high childhood BMI and adult coronary heart disease, diabetes and a range of cancers, but not stroke or breast cancer. The predictive accuracy of childhood BMI to predict any adult morbidity was very low, with most morbidities occurring in adults who were of healthy weight in childhood. Predictive accuracy of childhood obesity was moderate for predicting adult obesity, with a sensitivity of 30% and a specificity of 98%. Persistence of obesity from adolescence to adulthood was high. Thirty-four studies were included in the diagnostic accuracy review. Most of the studies used the least reliable reference standard (dual-energy X-ray absorptiometry); only 24% of studies were of high quality. The sensitivity of BMI for diagnosing obesity and overweight varied considerably; specificity was less variable. Pooled sensitivity of BMI was 74% (95% CI 64.2% to 81.8%) and pooled specificity was 95% (95% CI 92.2% to 96.4%). The acceptability to children and their carers of BMI or other common simple measures was generally good. LIMITATIONS Little evidence was available regarding childhood measures other than BMI. No individual-level analysis could be performed. CONCLUSIONS Childhood BMI is not a good predictor of adult obesity or adult disease; the majority of obese adults were not obese as children and most obesity-related adult morbidity occurs in adults who had a healthy childhood weight. However, obesity (as measured using BMI) was found to persist from childhood to adulthood, with most obese adolescents also being obese in adulthood. BMI was found to be reasonably good for diagnosing obesity during childhood. There is no convincing evidence suggesting that any simple measure is better than BMI for diagnosing obesity in childhood or predicting adult obesity and morbidity. Further research on obesity measures other than BMI is needed to determine which is the best tool for diagnosing childhood obesity, and new cohort studies are needed to investigate the impact of contemporary childhood obesity on adult obesity and obesity-related morbidities. STUDY REGISTRATION This study is registered as PROSPERO CRD42013005711. FUNDING The National Institute for Health Research Health Technology Assessment programme.
BACKGROUND:There is currently no standard practice for the monitoring of patients receiving treatment for osteoporosis. Repeated dual-energy X-ray absorptiometry (DXA) is commonly used for monitoring treatment response, but it has its limitations. Bone turnover markers have advantages over DXA as they are non-invasive, relatively cheap and can detect changes in bone turnover rates earlier. However, they do have disadvantages, particularly high within- and between-patient variability. The ability of bone turnover markers to identify treatment non-responders and predict future fracture risk has yet to be established. OBJECTIVES:We aimed to determine the clinical effectiveness, test accuracy, reliability, reproducibility and cost-effectiveness of bone turnover markers for monitoring the response to osteoporosis treatment. DATA SOURCES:We searched 12 electronic databases (including MEDLINE, EMBASE, The Cochrane Library and trials registries) without language restrictions from inception to March 2012. We hand-searched three relevant journals for the 12 months prior to May 2012, and websites of five test manufacturers and the US Food and Drug Administration (FDA). Reference lists of included studies and relevant reviews were also searched. REVIEW METHODS:A systematic review of test accuracy, clinical utility, reliability and reproducibility, and cost-effectiveness of two formation and two resorption bone turnover markers, in patients being treated for osteoporosis with any of bisphosphonate [alendronate (Fosamax, MSD), risedronate (Actonel, Warner Chilcott Company), zolendronate (Zometa, Novartis)], raloxifene (Evista, Eli Lilly and Company Ltd), strontium ranelate (Protelos, Servier Laboratories Ltd), denosumab (Prolia, Amgen Ltd) or teriparatide (Forsteo, Eli Lilly and Company Ltd), was undertaken according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. Given the breadth of the review question, a range of study designs and outcome measures were eligible. The development of a decision model was planned to determine the cost-effectiveness of bone turnover markers for informing changes in patient management if clinical effectiveness could be established. RESULTS:Forty-two studies (70 publications) met the inclusion criteria; none evaluated cost-effectiveness. Only five were randomised controlled trials (RCTs); these assessed only the impact of bone marker monitoring on aspects of adherence. No RCTs evaluated the effectiveness of bone turnover marker monitoring on treatment management. One trial suggested that feedback of a good response decreased non-persistence [hazard ratio (HR) 0.71, 95% confidence interval (CI) 0.53 to 0.95], and feedback of a poor response increased non-persistence (HR 2.22, 95% CI 1.27 to 3.89); it is not clear whether or not the trial recruited a population representative of that seen in clinical practice. Thirty-three studies reported results of some assessment of test accuracy, mostly correlations between changes in bone turnover and bone mineral density. Only four studies reported on intra- or interpatient reliability and reproducibility in treated patients. Overall, the results were inconsistent and inconclusive, owing to considerable clinical heterogeneity across the studies and the generally small sample sizes. As clinical effectiveness of bone turnover monitoring could not be established, a decision-analytic model was not developed. CONCLUSIONS:There was insufficient evidence to inform the choice of which bone turnover marker to use in routine clinical practice to monitor osteoporosis treatment response. The research priority is to identify the most promising treatment-test combinations for evaluation in subsequent, methodologically sound, RCTs. In order to determine whether or not bone turnover marker monitoring improves treatment management decisions, and ultimately impacts on patient outcomes in terms of reduced incidence of fracture, RCTs are required. Given the large number of potential patient population-treatment-test combinations, the most promising combinations would initially need to be identified in order to ensure that any RCTs focus on evaluating those strategies. As a result, the research priority is to identify these promising combinations, by either conducting small variability studies or initiating a patient registry to collect standardised data. FUNDING:The National Institute for Health Research Health Technology Assessment programme.
Financial abuse of elders is an under acknowledged problem and professionals’ judgements contribute to both the prevalence of abuse and the ability to prevent and intervene. In the absence of a definitive “gold standard” for the judgement, it is desirable to try and bring novice professionals’ judgemental risk thresholds to the level of competent professionals as quickly and effectively as possible. This study aimed to test if a training intervention was able to bring novices’ risk thresholds for financial abuse in line with expert opinion.
Background: Time pressure is common in acute healthcare and significantly influences clinical judgement and decision making. Despite nurses' judgements being studied since the 1960s, the empirical picture of how time pressure impacts on nurses' judgement strategies and outcomes remain undeveloped. This paper aims to assess alterations in nurses' judgement strategies and outcomes under time pressure in a simulated acute care setting.Methods: In a simulated acute care environment, ninety-seven nurses were exposed to 25 clinical scenarios under time pressured and no time pressured conditions. Scenarios were randomly sampled from a large dataset of patient cases. A reference standard (judgement correctness) was generated from the same patient case records. In 12 of the scenarios only 20 seconds per judgement was allowed, in the other 13 scenarios no time pressure existed. Percentage of correct judgments in both conditions was calculated. Logistic regression modelling (of 2,425 observations) described the relationship between information cues used and judgments made. The degree of attention paid to particular cues was captured by calculating cue relative weights. The clustering effect of nurses was countered by estimating robust standard errors. The Chow test was used to test the null hypothesis that differences in regression coefficients in time pressure and no time pressure models were zero.Results: Compared to no time pressure, no significant difference was observed in the proportion of correct judgments when nurses were put under time pressure. However, time pressure significantly impacted on the judgment strategies employed. Whilst nurses predominantly used respiration rate to make judgements, they used fewer cues to reach their clinical judgements under time pressure. The relative weighting afforded to heart rate was much smaller in the time pressure regression model, indicating that nurses paid significantly less attention to it when making judgements under time pressure.Conclusions: Time pressure had a significant effect on nurses' judgement strategies but not outcomes. Nurses tended to use less information to reach judgements under time pressure, but not at the expense of judgment accuracy. Findings imply that nurses are capable of using adaptive judgement strategies to cope with moderate time pressures when making clinical judgements in acute care.
Purpose To evaluate the available evidence for the clinical effectiveness of the EOS ® 2D/3D X-ray imaging system for the evaluation and monitoring of scoliosis and other relevant orthopaedic conditions. Methods A systematic review of studies of EOS ® , compared with standard X-ray film, computed radiography or digital radiography, of patients with orthopaedic conditions was undertaken. Ten electronic databases were searched. The quality of the included studies was assessed and a narrative synthesis undertaken. Results Three small, limited quality studies, primarily of children with scoliosis, were identified. No patient health outcomes were reported. Spinal image quality was comparable or better overall with EOS ® . Radiation dose was considerably lower with EOS ® than X-ray film or computed radiography; the mean entrance surface dose was over five times lower with EOS ® for the posteroanterior spine radiograph and over six times lower for the lateral spine radiograph. Conclusions The available clinical evidence for EOS ® is limited to establishing its basic technical ability. The technical advancements associated with EOS ® (the ability to generate a full body scan and to construct a three-dimensional model from synchronously acquired lateral and posteroanterior images) have not been evaluated in terms of their ability to improve patient outcomes. Whilst radiation dose is a concern for orthopaedic patients who require repeated imaging, it is difficult to quantify the reductions in radiation dose seen with EOS ® in terms of patient health benefits. Clinical studies that investigate the impact of EOS ® on patient management are required.
The validity of studies describing clinicians’ judgements based on their responses to paper cases is questionable, because - commonly used - paper case simulations only partly reflect real clinical environments. In this study we test whether paper case simulations evoke similar risk assessment judgements to the more realistic simulated patients used in high fidelity physical simulations.
The National Institute for Health and Clinical Excellence (NICE) invited the manufacturer of golimumab (Schering-Plough/Centocor) to submit evidence for the clinical and cost effectiveness of this drug for the treatment of active and progressive psoriatic arthritis (PsA) in patients who have responded inadequately to previous disease-modifying anti-rheumatic drugs (DMARDs). The Centre for Reviews and Dissemination and the Centre for Health Economics at the University of York were commissioned to act as the Evidence Review Group (ERG) to critically appraise the evidence presented by the manufacturer. This article provides a description of the company submission, the ERG review and the resulting NICE guidance. The ERG critically reviewed the evidence presented in the manufacturer’s submission and identified areas requiring clarification, for which the manufacturer provided additional evidence.