Abstract The Commission on Laboratory Diagnostics in Diabetology was founded in 2015 at the suggestion and with the support of the Executive Board of the German Diabetes Society (DDG) and the German Society of Clinical Chemistry and Laboratory Medicine (DGKL), with the aim of addressing methodological aspects for the reliable measurement of clinical chemistry measurands such as glucose, HbA 1c , insulin, C-peptide, antibodies, etc. This mini-review looks back on the work of the KLD over the past 10 years and briefly outlines current activities and future steps.
Point-of-care testing (POCT) is becoming an increasingly popular way to perform laboratory tests closer to the patient. This option has several recognized advantages, such as accessibility, portability, speed, convenience, ease of use, ever-growing test panels, lower cumulative healthcare costs when used within appropriate clinical pathways, better patient empowerment and engagement, and reduction of certain pre-analytical errors, especially those related to specimen transportation. On the other hand, POCT also poses some limitations and risks, namely the risk of lower accuracy and reliability compared to traditional laboratory tests, quality control and connectivity issues, high dependence on operators (with varying levels of expertise or training), challenges related to patient data management, higher costs per individual test, regulatory and compliance issues such as the need for appropriate validation prior to clinical use (especially for rapid diagnostic tests; RDTs), as well as additional preanalytical sources of error that may remain undetected in this type of testing, which is usually based on whole blood samples (i.e., presence of interfering substances, clotting, hemolysis, etc.). There is no doubt that POCT is a breakthrough innovation in laboratory medicine, but the discussion on its appropriate use requires further debate and initiatives. This collective opinion paper, composed of abstracts of the lectures presented at the two-day expert meeting "Point-Of-Care-Testing: State of the Art and Perspective" (Venice, April 4-5, 2024), aims to provide a thoughtful overview of the state-of-the-art in POCT, its current applications, advantages and potential limitations, as well as some interesting reflections on the future perspectives of this particular field of laboratory medicine.
In diesem Kapitel werden die Referenzwerte der wichtigsten Laborparameter – in Serum und Urin – sowie die Umrechenfaktoren von konventionellen zu SI-Einheiten tabellarisch aufgeführt.
Die Labormedizin hat die Aufgabe, durch Messung physikalischer, hämatologischer, molekularbiologischer und (bio)chemischer Eigenschaften von menschlichem Untersuchungsmaterial gezielt gestellte ärztliche Fragen im Hinblick auf Diagnostik, Therapieverlauf, Prävention und Prognose von Krankheiten zu beantworten. Relevante Kenngrößen werden in dem Kapitel ebenso wie die Qualitätssicherung im medizinischen Labor vorgestellt.
Purpose A host-protein signature score, consisting of serum-concentrations of C-reactive protein, tumour necrosis factor-related apoptosis-inducing ligand, and interferon gamma-induced protein 10, was validated for distinguishing between bacterial and viral infections as an antimicrobial stewardship measure for routine clinical practice among adult patients in a German tertiary hospital. Methods This single-centre, explorative study prospectively assessed the host-protein signature score, comparing it with serum procalcitonin (PCT) in patients with blood stream infections (BSI) and evaluating its efficacy in patients with viral infections against the standard of care (SOC) to assess the need for antibiotics due to suspected bacterial super/coinfection. Manufacturer-specified threshold scores were used to differentiate viral (< 35) and bacterial (> 65) infections. Results Ninety-seven patients (BSI [n = 56]; viral infections [n = 41]) were included. The score (cut-off score > 65) tended to detect BSI with higher sensitivity than did PCT (cut-off > 0.5 ng/mL) (87.5% vs. 76.6%). Three patients (5.4%) with BSI had a score < 35. One patient with BSI did not receive antibiotic treatment following SOC prior to positive blood culture results. Among patients with viral infections, 29 (70.7%) had scores > 65, indicating bacterial superinfections. Additionally, 11 patients (26.8%) had scores < 35, indicating no bacterial superinfections. In total, the antibiotic treatment discrepancy in the viral group between the SOC and a host-protein signature score guided approach was 2/41 patients (4.9%). Conclusion The score tended towards a higher sensitivity in detecting BSI than that with PCT. However, its impact on reducing antibiotic use in viral infections was minor compared with that of SOC.
Background: Current assays for the detection of (allo)antibodies to platelet antigens are often laborious and widely based on the presence of well-characterized donor platelets. Objectives: To develop an easy-to-perform, sensitive, and specific test for the detection of antibodies against platelet antigens, in particular, glycoprotein (GP) antigens, called "Recombinantly Expressed Tagged SUrface Protein" (RETSUP) assay, which does not require donor platelets. Methods: Twin-Strep-tagged GP complexes were recombinantly expressed in human embryonic kidney 293 cells after stable transfection. These cell lines were used as antigen sources in the RETSUP assay, combining cell-based and enzyme-linked immunosorbent assay-based assay procedures. The assay performance was tested with recombinant antibodies, anti-human platelet antigen (HPA) reference plasmas, and anti-HPA patient sera. Results: Human embryonic kidney 293 cell lines stably expressing either Twin-Streplabeled GPIa/IIa, GPIIb/IIIa, GPIb/IX, or GPIb/IX/V complexes or GPV as well as the distinct HPA-1, HPA-3, and HPA-5 epitopes were successfully generated. Applying the generated GP-expressing cell lines, the developed RETSUP assay proved very sensitive and specific with recombinant antibodies targeting different GPs and human plasma/ serum samples. The results of the test were not affected by the GP carrying the TwinStrep-tag or by using freshly harvested or cryopreserved cells. Conclusion: The RETSUP assay is an easy-to-perform, sensitive, and specific assay for the detection of plasma/serum antibodies to platelet GP, with performance comparable to or better than those of current state-of-the-art assays in antiplatelet antibody diagnostics. Owing to the recombinant nature of the target antigens, it can be easily adapted to detect antibodies in other antibody-mediated diseases.
OBJECTIVES:This study aimed to evaluate discrepancies in potassium measurements between point-of-care testing (POCT) and central laboratory (CL) methods, focusing on the impact of hemolysis on these measurements and its impact in the clinical practice in the emergency department (ED). METHODS:A retrospective analysis was conducted using data from three European university hospitals: Technische Universitat München (Germany), Hospital Universitario La Paz (Spain), and Erasmus University Medical Center (The Netherlands). The study compared POCT potassium measurements in EDs with CL measurements. Data normalization was performed in categories for potassium levels (kalemia) and hemolysis. The severity of discrepancies between POCT and CL potassium measurements was assessed using the reference change value (RCV). RESULTS:The study identified significant discrepancies in potassium between POCT and CL methods. In comparing POCT normo- and mild hypokalemia against CL results, differences of -4.20 % and +4.88 % were noted respectively. The largest variance in the CL was a +4.14 % difference in the mild hyperkalemia category. Additionally, the RCV was calculated to quantify the severity of discrepancies between paired potassium measurements from POCT and CL methods. The overall hemolysis characteristics, as defined by the hemolysis gradient, showed considerable variation between the testing sites, significantly affecting the reliability of potassium measurements in POCT. CONCLUSIONS:The study highlighted the challenges in achieving consistent potassium measurement results between POCT and CL methods, particularly in the presence of hemolysis. It emphasised the need for integrated hemolysis detection systems in future blood gas analysis devices to minimise discrepancies and ensure accurate POCT results.
Objective: To investigate whether goal-directed albumin substitution during surgery and postanesthesia care to maintain a serum albumin concentration >30 g/L can reduce postoperative complications. Background: Hypoalbuminemia is associated with numerous postoperative complications. Since albumin has important physiological functions, substitution of patients with hypoalbuminemia is worth considering. Methods: We conducted a single-center, randomized, controlled, outcome assessor–blinded clinical trial in adult patients, American Society of Anesthesiologists physical status classification 3 to 4 or undergoing high-risk surgery. Patients, whose serum albumin concentration dropped <30 g/L were randomly assigned to goal-directed albumin substitution maintaining serum concentration >30 g/L or to standard care until discharge from the postanesthesia intermediate care unit. Standard of care allowed albumin substitution in hemodynamic instable patients with serum concentration <20 g/L, only. Primary outcome was the incidence of postoperative complications ≥2 according to the Clavien-Dindo Classification in at least 1 of 9 domains (pulmonary, infectious, cardiovascular, neurological, renal, gastrointestinal, wound, pain, and hematological) until postoperative day 15. Results: Of 2509 included patients, 600 (23.9%) developed serum albumin concentrations <30 g/L. Human albumin 60 g (40–80 g) was substituted to 299 (99.7%) patients in the intervention group and to 54 (18.0%) in the standard care group. At least 1 postoperative complication classified as Clavien-Dindo Classification ≥2 occurred in 254 of 300 patients (84.7%) in the intervention group and in 262 of 300 (87.3%) in the standard treatment group (risk difference −2.7%, 95% CI, −8.3% to 2.9%). Conclusion: Maintaining serum albumin concentration of >30 g/L perioperatively cannot generally be recommended in high-risk noncardiac surgery patients.
Background:During the last decade, Germany has seen an increased prevalence and a redistribution from undetected to diagnosed diabetes mellitus. Due to this substantial epidemiological development, the number of people with documented type 2 diabetes was 8.7 million in 2022. An estimated two million undiagnosed subjects are to be added. Beyond that, the life expectancy of diabetic subjects is increasing due to more responsive health systems in terms of care. Possible reasons include improved screening of at-risk individuals, the introduction of HbA1c for diagnosis in 2010, and the higher use of risk scores. Additionally, quality aspects of the laboratory methodology should be taken into consideration.Methods:Epidemiology and clinical management of diabetes in Germany are presented in the light of publications retrieved by a selective search of the PubMed database. Additionally, the data from German external quality assessment (EQA) surveys for the measurands glucose in plasma and HbA1c in whole blood, reviewed from 2010 until 2022, were evaluated. Above this, data concerning the analytical performance of near-patient glucometer devices, according to the ISO norm 15197:2013, were analyzed.Results:Two laboratory aspects are in good accordance with the observation of an increase in the diabetes mellitus prevalence when retrospectively reviewing the period 2010 to 2022: First, the analytical performance according to the ISO norm 15197:2013 of the glucometer devices widely used by patients with diabetes for the glucose self-testing, has improved during this period. Secondly, concerning the EQA program of INSTAND, the number of participating laboratories raised significantly in Germany. The spreads of variations of the specified results for plasma glucose remained unchanged between 2010 and 2022, whereas for HbA1c a significant decrease of the result scattering could be observed.Conclusion:These retrospectively established findings testify to an excellent analytical quality of laboratory diagnostics for glucose and HbA1c throughout Germany which may be involved in a better diagnosis and therapy of previously undetected diabetes mellitus.
As hormonal disorders are linked to several diseases, the accurate quantitation of steroid hormone levels in serum is crucial in order to provide patients with a reliable diagnosis. Mass spectrometry-based methods are regarded as having the highest level of specificity and sensitivity. However, immunoassays are more commonly used in routine diagnostics to measure steroid levels as they are more cost effective and straightforward to conduct. This study analyzes the external quality assessment results for the measurement of testosterone, progesterone and 17β-estradiol in serum using immunoassays between early 2020 and May 2022. As reference measurement procedures are available for the three steroid hormones, the manufacturer-specific biases were normalized to the reference measurement values. The manufacturer-specific coefficients of variation were predominantly inconspicuous, below 20% for the three hormones when outliers are disregarded, however there were large differences between the various manufacturer collectives. For some collectives, the median bias to the respective reference measurement value was repeatedly greater than ±35%, which is the acceptance limit defined by the German Medical Association. In the case of testosterone and progesterone determination, some collectives tended to consistently over- or underestimate analyte concentrations compared to the reference measurement value, however, for 17β-estradiol determination, both positive and negative biases were observed. This insufficient level of accuracy suggests that cross-reactivity continues to be a fundamental challenge when antibody detection is used to quantify steroids with a high structural similarity. Distinct improvements in standardization are required to provide accurate analysis and thus, reliable clinical interpretations. The increased accuracy of the AX immunoassay for testosterone measurement, as observed in the INSTAND EQAs between 2020 and 2022, could be the result of a recalibration of the assay and raises hope for further improvement of standardization of immunoassay-based steroid hormone analyses in the coming years.
Therapeutic drug monitoring (TDM) is an important tool in precision medicine as it allows estimating pharmacodynamic and pharmacokinetic effects of drugs in clinical settings. An accurate, fast and real-time determination of the drug concentrations in patients ensures fast decision-making processes at the bedside to optimize the clinical treatment. Surface-enhanced Raman spectroscopy (SERS), which is based on the application of metallic nanostructured substrates to amplify the inherent weak Raman signal, is a promising technique in medical research due to its molecular specificity and trace sensitivity accompanied with short detection times. Therefore, we developed a SERS-based detection scheme using silicon nanowires decorated with silver nanoparticles, fabricated by means of top-down etching combined with chemical deposition, to detect the antibiotic ceftriaxone (CRO) in spiked fresh plasma and microdialysis samples. We successfully detected CRO in both matrices with an LOD of 94 μM in protein-depleted fresh plasma and 1.4 μM in microdialysate.