BACKGROUND:In mitral regurgitation (MR), temporal variation of MR flow has been considered an important reason for inaccurate MR grading. Current echocardiographic methods for assessing temporal MR flow variation are complex, and their clinical relevance has not been investigated. In this study, we investigated whether assessing MR flow variation using a dimensionless index with echocardiography is feasible, clinically meaningful, and related to patient outcomes. METHODS:Consecutive patients with mitral valve prolapse (MVP, n = 244) and functional MR (FMR, n = 396) underwent comprehensive echocardiography. Mitral regurgitation severity was assessed using an integrated approach advocated by current guidelines. The MR continuous-wave Doppler envelope was divided into 3 segments of equal duration. Each segment's pixel intensity was assessed to calculate the pixel variation score (PVS). RESULTS:The PVS was lower in FMR patients than in MVP patients. Lower PVS was associated with worse MR, larger left atrial and left ventricular dimensions, lower ejection fraction, and higher pulmonary artery pressures. In MVP, PVS was significantly associated with postoperative left ventricular reverse remodeling and was able to reclassify most patients in whom single-frame measures overestimated MR severity. Finally, PVS had incremental prognostic value on top of clinical and echocardiographic predictors of outcome. CONCLUSIONS:Temporal variation in MR flow can reliably be assessed with echocardiography through analysis of the continuous-wave Doppler signal. A high PVS value may alert the echocardiographer to defer from single-frame MR grading and also suggests that the MR is probably not severe.
PURPOSE:Intraventricular blood flow dynamics are associated with cardiac function. Accurate, noninvasive, and easy assessments of hemodynamic quantities (such as velocity, vortex, and pressure) could be an important addition to the clinical diagnosis and treatment of heart diseases. However, the complex time-varying flow brings many challenges to the existing noninvasive image-based hemodynamic assessments. The development of reliable techniques and analysis tools is essential for the application of hemodynamic biomarkers in clinical practice.METHODS:In this study, a time-resolved particle tracking method, Shake-the-Box, was applied to reconstruct the flow in a realistic left ventricle (LV) silicone model with biological valves. Based on the obtained velocity, 4D pressure field was calculated using a Poisson equation-based pressure solver. Furthermore, flow analysis by proper orthogonal decomposition (POD) of the 4D velocity field has been performed.RESULTS:As a result of the Shake-the-Box algorithm, we have extracted: (i) particle positions, (ii) particle tracks, and finally, (iii) 4D velocity fields. From the latter, the temporal evolution of the 3D pressure field during the full cardiac cycle was obtained. The obtained maximal pressure difference extracted along the base-to-apex was about 2.7 mmHg, which is in good agreement with those reported in vivo. The POD analysis results showed a clear picture of different scale of vortices in the pulsatile LV flow, together with their time-varying information and corresponding kinetic energy content. To reconstruct 95% of the kinetic energy of the LV flow, only the first six POD modes would be required, leading to significant data reduction.CONCLUSIONS:This work demonstrated Shake-the-Box is a promising technique to accurately reconstruct the left ventricle flow field in vitro. The good spatial and temporal resolutions of the velocity measurements enabled a 4D reconstruction of the pressure field in the left ventricle. The application of POD analysis showed its potential in reducing the complexity of the high-resolution left ventricle flow measurements. For future work, image analysis, multi-modality flow assessments, and the development of new flow-derived biomarkers can benefit from fast and data-reducing POD analysis.
To assess errors associated with EPI‐accelerated intracardiac 4D flow MRI (4DEPI) with EPI factor 5, compared with non‐EPI gradient echo (4DGRE).
Left ventricular (LV) blood flow is an inherently complex time-varying 3-D phenomenon, where 2-D quantification often ignores the effect of out-of-plane motion. In this study, we describe high frame rate 4-D echocardiographic particle image velocimetry (echo-PIV) using a prototype matrix transesophageal transducer and a dynamic LV phantom for testing the accuracy of echo-PIV in the presence of complex flow patterns. Optical time-resolved tomographic PIV (tomo-PIV) was used as a reference standard for comparison. Echo-PIV and tomo-PIV agreed on the general profile of the LV flow patterns, but echo-PIV smoothed out the smaller flow structures. Echo-PIV also underestimated the flow rates at greater imaging depths, where the PIV kernel size and transducer point spread function were large relative to the velocity gradients. We demonstrate that 4-D echo-PIV could be performed in just four heart cycles, which would require only a short breath-hold, providing promising results. However, methods for resolving high velocity gradients in regions of poor spatial resolution are required before clinical translation.
Left ventricular flow is intrinsically complex, three-dimensional and unsteady. Its features are susceptible to cardiovascular pathology and treatment, in particular to surgical interventions involving the valves (mitral valve replacement). To improve our understanding of intraventricular fluid mechanics and the impact of various types of prosthetic valves thereon, we have developed a custom-designed versatile left ventricular phantom with anatomically realistic moving left ventricular membrane. A biological, a tilting disc and a bileaflet valve (in two different orientations) were mounted in the mitral position and tested under the same settings. To investigate 3D flow within the phantom, a four-view tomographic particle image velocimetry setup has been implemented. The results compare side-by-side the evolution of the 3D flow topology, vortical structures and kinetic energy in the left ventricle domain during the cardiac cycle. Except for the tilting disc valve, all tested prosthetic valves induced a crossed flow path, where the outflow crosses the inflow path, passing under the mitral valve. The biological valve shows a strong jet with a peak velocity about twice as high compared to all mechanical heart valves, which makes it easier to penetrate deeply into the cavity. Accordingly, the peak kinetic energy in the left ventricle in case of the biological valve is about four times higher than the mechanical heart valves. We conclude that the tomographic particle imaging velocimetry setup provides a useful ground truth measurement of flow features and allows a comparison of the effects of different valve types on left ventricular flow patterns.
The characterization of flow patterns in the left ventricle may help the development and interpretation of flow-based parameters of cardiac function and (patho-)physiology. Yet, in vivo visualization of highly dynamic three-dimensional flow patterns in an opaque and moving chamber is a challenging task. This has been shown in several recent multidisciplinary studies where in vivo imaging methods are often complemented by in silico solutions, or by in vitro methods. Because of its distinctive features, particle image velocimetry (PIV) has been extensively used to investigate flow dynamics in the cardiovascular field. However, full volumetric PIV data in a dynamically changing geometry such as the left ventricle remain extremely scarce, which justifies the present study. An investigation of the left ventricle flow making use of a customized cardiovascular simulator is presented; a multiplane scanning-stereoscopic PIV setup is used, which allows for the measurement of independent planes across the measurement volume. Due to the accuracy in traversing the illumination and imaging systems, the present setup allows to reconstruct the flow in a 3D volume performing only one single calibration. The effects of the orientation of a prosthetic mitral valve in anatomical and anti-anatomical configurations have been investigated during the diastolic filling time. The measurement is performed in a phase-locked manner; the mean velocity components are presented together with the vorticity and turbulent kinetic energy maps. The reconstructed 3D flow structures downstream the bileaflet mitral valve are shown, which provides additional insight of the highly three-dimensional flow.
In the physics teaching community, Tracker is well known as a user-friendly open source video analysis software, authored by Douglas Brown. With this tool, the user can trace markers indicated on a video or on stroboscopic photos and perform kinematic analyses. Tracker also includes a data modeling tool that allows one to fit some theoretical equations of motion onto experimentally obtained data. In the field of particle mechanics, Tracker has been effectively used for learning and teaching about projectile motion, “toss up” and free-fall vertical motion, and to explain the principle of mechanical energy conservation. Also, Tracker has been successfully used in rigid body mechanics to interpret the results of experiments with rolling/slipping cylinders and moving rods. In this work, I propose an original method in which Tracker is used to analyze virtual computer simulations created with a physics-based motion solver, instead of analyzing video recording or stroboscopic photos. This could be an interesting approach to study kinematics and dynamics problems in physics education, in particular when there is no or limited access to physical labs. I demonstrate the working method with a typical (but quite challenging) problem in classical mechanics: a slipping/rolling cylinder on a rough surface.
This work is about planar rigid-body kinematics and, in particular, the principle of the instantaneous center of rotation (IC). Using a computer simulated approach, a workflow is presented that results in a visual representation of the locus of the IC, based on particle image velocimetry (PIV). Here, a small number of digital animations of textured objects are created with multibody dynamics software, and later imported in PIV software to extract the velocity field (magnitude and direction) of objects moving within a plane. We believe the workflow presented may help learners improve their understanding of the concept of the IC, thus enhancing their knowledge of rigid body kinematics.
Chronic glenohumeral dislocation is a rare entity and several treatment options have been proposed. The aim of this study is to report the long-term follow-up of the reversed shoulder arthroplasty in patients with chronic glenohumeral dislocation. A retrospective analysis of all patients between January 2002 and December 2012 that were treated with a reversed shoulder arthroplasty for chronic anterior glenohumeral dislocations was performed. Pre-operative CT evaluation of the bone loss and fatty degeneration of the rotator cuff muscles was performed. Pre- and postoperative Constant-Murley score was evaluated. 6 patients (4 males and 2 females) with anterior glenohumeral dislocations were evaluated. Average age was 73 years (between 65-86 years). The average time of dislocation was 18 weeks (between 4 and 52 weeks). Average time of follow-up was 39 months (between 12 and 90 months). The CM improved from 33 (between 17 and 45) pre-op to 76 postop (between 55 and 89). No postoperative complications were observed. Reversed shoulder arthroplasty gives good results in case of chronic glenohumeral dislocation.
Background: Effective arterial elastance (Ea), the ratio of left ventricular (LV) end-systolic pressure and stroke volume, is increasingly being used to quantify properties of the arterial system and in conjunction with LV end-systolic elastance, is used to assess combined “ventricular-arterial stiffening”. However, theoretical modeling studies indicate that Ea is not prominently affected by arterial stiffness.
BACKGROUND:Trochlear dysplasia appears in different geometrical variations. The Dejour classification is widely used to grade the severity of trochlear dysplasia and to decide on treatment.PURPOSE:To investigate the effect of trochlear dysplasia on patellofemoral biomechanics and to determine if different types of trochlear dysplasia have different effects on patellofemoral biomechanics.STUDY DESIGN:Controlled laboratory study.METHODS:Trochlear dysplasia was simulated in 4 cadaveric knees by replacing the native cadaveric trochlea with different types of custom-made trochlear implants, manufactured with 3-dimensional printing. For each knee, 5 trochlear implants were designed: 1 implant simulated the native trochlea (control condition), and 4 implants simulated 4 types of trochlear dysplasia. The knees were subjected to 3 biomechanical tests: a squat simulation, an open chain extension simulation, and a patellar stability test. The patellofemoral kinematics, contact area, contact pressure, and stability were compared between the control condition (replica implants) and the trochlear dysplastic condition and among the subgroups of trochlear dysplasia.RESULTS:The patellofemoral joint in the trochlear dysplastic group showed increased internal rotation, lateral tilt, and lateral translation; increased contact pressures; decreased contact areas; and decreased stability when compared with the control group. Within the trochlear dysplastic group, the implants graded as Dejour type D showed the largest deviations for the kinematical parameters, and the implants graded as Dejour types B and D showed the largest deviations for the patellofemoral contact areas and pressures.CONCLUSION:Patellofemoral kinematics, contact area, contact pressure, and stability are significantly affected by trochlear dysplasia. Of all types of trochlear dysplasia, the models characterized with a pronounced trochlear bump showed the largest deviations in patellofemoral biomechanics.CLINICAL RELEVANCE:Investigating the relationship between the shape of the trochlea and patellofemoral biomechanics can provide insight into the short-term effects (maltracking, increased pressures, and instability) and long-term effects (osteoarthritis) of different types of trochlear dysplasia. Furthermore, this investigation provides an empirical explanation for better treatment outcomes of trochleoplasty for Dejour types B and D dysplasia.
The aim of this project is to map the 3D intracardiac spatiotemporal structure flow by mean phase-locked Stereo-PIV. The developed setup permits the flow field measurment in the whole left ventricle model without repeating the complex stereo calibration. It consisted of coupling Stereo-PIV apparatus and cardiovascular simulator system.
The authors hypothesise that the trochlear dysplastic distal femur is not only characterised by morphological changes to the trochlea. The purpose of this study is to describe the morphological characteristics of the trochlear dysplastic femur in and outside the trochlear region with a landmark-based 3D analysis.
Background: Obesity is an established risk factor for heart failure. We aimed to comprehensively characterize early subclinical obesity-related abnormalities in diastolic and systolic function in a large general population sample. Methods: We studied 1,603 middle-aged adults enrolled in the Asklepios study. We assessed standard Doppler indices of diastolic function, speckle-tracking echocardiography-derived myocardial systolic deformation and parameters describing the elastic recoil-driven early diastolic suction attribute of the left ventricle (LV), obtained via kinematic modeling of early mitral inflow. All models were adjusted for, age, gender and LV size. Results: Speckle tracking echocardiography revealed decreased longitudinal peak systolic strain in obesity (-17.3; 95%CI=-17. 7 to -16.8; P=0.001), with preserved circumferential strain (P=0.35). Obesity was also independently associated with lower stored elastic strain energy (9013 vs. 10695 m 2 /s 2 ; P<0.0001) available at mitral valve opening, resulting in a lower peak force driving early diastolic filling (1824 vs. 2013 m/s2; P<0.001). Despite exhibiting a lower early diastolic mitral annular tissue velocity (8.32 vs. 9.6 cm/s; P<0.001), obese subjects demonstrated a significantly greater early diastolic mitral inflow propagation velocity (81.5 vs. 73.8 cm/s; P<0.001) and a lower damping constant c (15.1 vs. 16.7 /s; P<0.01), which represents the dampening effects of slow LV relaxation and increased tissue viscoelasticity preventing rapid LV filling). Conclusions: Our results suggest that the main abnormality underlying abnormal early diastolic LV filling in obesity is a reduced stored elastic strain / potential energy during systolic contraction, leading to decreased mechanical recoil during early diastole. This may be related to loss of longitudinal (but not circumferential) systolic function. Our findings have implications for our understanding the underlying mechanisms of obesity-related LV dysfunction.
In this paper, a validation of a recently developed fluid-structure interaction (FSI) coupling algorithm to simulate numerically the dynamics of an aortic bileaflet mechanical heart valve (BMHV) is performed. This validation is done by comparing the numerical simulation results with in vitro experiments. For the in vitro experiments, the leaflet kinematics and flow fields are obtained via the particle image velocimetry (PIV) technique. Subsequently, the same case is numerically simulated by the coupling algorithm and the resulting leaflet kinematics and flow fields are obtained. Finally, the results are compared, revealing great similarity in leaflet motion and flow fields between the numerical simulation and the experimental test. Therefore, it is concluded that the developed algorithm is able to capture very accurately all the major leaflet kinematics and dynamics and can be used to study and optimize the design of BMHVs.