This paper investigates the equivalence of the two popular approaches to pulsewidth modulation (PWM) in induction motor drives, namely, the triangle comparison approach and the space vector approach. It brings out the conditions wherein they are equivalent and wherein they are not. It shows that the space vector approach is more general and offers more degrees of freedom compared to the triangle comparison approach. Even a limited exploitation of these flexibilities has been reported to have improved the drive performance significantly. This gives adequate motivation to exploit these flexibilities further.
For longer life of alternating-current (ac) machines, it is desirable to feed them by sinusoidal voltages. This can be achieved by connecting an LC filter between the voltage source inverter and the motor. However, the LC filter creates unwanted oscillation at system resonant frequency. A resistance connected in series with the capacitor is a solution to damp out the resonant-frequency oscillation...
Load commutated inverter (LCI) fed wound field synchronous motor (WFSM) is used for high speed, medium voltage, high power industrial applications. The control popularly known as “self control” is well reported for cylindrical rotor WFSM. Such a control when applied for salient pole WFSM becomes complex due to saliency and requires rigorous off-line calculations for generation of look up tables etc. In addition, the self control technique does not include cancelling out the coupling between torque and flux control which exists in salient pole WFSM. In this regard, this paper proposes to adopt field oriented control, generally used with voltage source inverter fed drives, for the control of salient pole WFSM fed from LCI. It offers many advantages over self control technique besides providing accurate control such as decoupled flux and torque control, simple real-time calculation of field current over-excitation considering instantaneous load torque as well as speed of the motor, sensor-less techniques, simplification in SCR gate pulse generation etc. In this paper the starting of the LCI, which is generally done using “dc-link current pulsing” technique, is not considered. The performance of the drive is demonstrated with elaborate experimental observations on a 15.8 hp salient pole WFSM.
Conventional thyristor-based load commutated inverter (LCI)-fed wound field synchronous machine operates only above a minimum speed that is necessary to develop enough back emf to ensure commutation. The drive is started and brought up to a speed of around 10-15% by a complex 'dc link current pulsing' technique. During this process, the drive have problems such as pulsating torque, insufficient average starting torque, longer starting time, etc. In this regard a simple starting and low-speed operation scheme, by employing an auxiliary low-power voltage source inverter (VSI) between the LCI and the machine terminals, is presented in this study. The drive is started and brought up to a low speed of around 15% using the VSI alone with field oriented control. The complete control is then smoothly and dynamically transferred to the conventional LCI control. After the control transfer, the VSI is turned off and physically disconnected from the main circuit. The advantages of this scheme are smooth starting, complete control of torque and flux at starting and low speeds, less starting time, stable operation, etc. The voltage rating of the required VSI is very low of the order of 10-15%, whereas the current rating is dependent on the starting torque requirement of the load. The experimental results from a 15.8 hp LCI-fed wound field synchronous machine are given to demonstrate the scheme.
Neutral point clamped (NPC), three level converters with insulated gate bipolar transistor devices are very popular in medium voltage, high power applications. DC bus short circuit protection is usually done, using the sensed voltage across collector and emitter (i.e., V CE sensing), of all the devices in a leg. This feature is accommodated with the conventional gate drive circuits used in the two level converters. The similar gate drive circuit, when adopted for NPC three level converter protection, leads to false V CE fault signals for inner devices of the leg. The paper explains the detailed circuit behavior and reasons, which result in the occurrence of such false V CE fault signals. This paper also illustrates that such a phenomenon shows dependence on the power factor of the supplied three-phase load. Finally, experimental results are presented to support the analysis. It is shown that the problem can be avoided by blocking out the V CE sense fault signals of the inner devices of the leg.
Till date load-commutated inverter (LCI)-fed synchronous motor drive configuration is popular in high power applications (>10 MW). The leading power factor operation of synchronous motor by excitation control offers this simple and rugged drive structure. On the contrary, LCI-fed induction motor drive is absent as it always draws lagging power factor current. Therefore, complicated commutation circuit is required to switch off thyristors for a current source inverter (CSI)-driven induction motor. It poses the major hindrance to scale up the power rating of CSI-fed induction motor drive. Anew power topology for LCI-fed induction motor drive for medium-voltage drive application is proposed. A new induction machine (active-reactive induction machine) with two sets of three-phase winding is introduced as a drive motor. The proposed power configuration ensures sinusoidal voltage and current at the motor terminals. The total drive power is shared among a thyristor-based LCI, an insulated gate bipolar transistor (IGBT)-based two-level voltage source inverter (VSI), and a three-level VSI. The benefits of SCRs and IGBTs are explored in the proposed drive. Experimental results from a prototype drive verify the basic concepts of the drive.
A new configuration is proposed for high-power induction motor drives. The induction machine is provided with two three-phase stator windings with their axes in line. One winding is designed for higher voltage and is meant to handle the main (active) power. The second winding is designed for lower voltage and is meant to carry the excitation (reactive) power. The excitation winding is powered by an insulated-gate-bipolar-transistor-based voltage source inverter with an output filter. The power winding is fed by a load-commutated current source inverter. The commutation of thyristors in the load-commutated inverter (LCI) is achieved by injecting the required leading reactive power from the excitation inverter. The MMF harmonics due to the LCI current are also cancelled out by injecting a suitable compensating component from the excitation inverter, so that the electromagnetic torque of the machine is smooth. Results from a prototype drive are presented to demonstrate the concept.
Load commutated inverter (LCI)-fed wound field synchronous motor drives are used for medium-voltage high-power drive applications. This drive suffers from drawbacks such as complex starting procedure, sixth harmonic torque pulsations, quasi square wave motor current, notches in the terminal voltages, etc. In this paper, a hybrid converter circuit, consisting of an LCI and a voltage source inverter (VSI), is proposed, which can be a universal high-power converter solution for wound field synchronous motor drives. The proposed circuit, with the addition of a current-controlled VSI, overcomes nearly all of the shortcomings present in the conventional LCI-based system besides providing many additional advantages. In the proposed drive, the motor voltage and current are always sinusoidal even with the LCI switching at the fundamental frequency. The performance of the drive is demonstrated with detailed experimental waveforms from a 15.8-hp salient pole wound field synchronous machine. Finally, a brief description of the control scheme used for the proposed circuit is given.
| A variety of solutions are available today from industry for high power variable speed AC motor drive applications, starting from a power rating of a few 100 kW to several 10’s of Megawatts. These drives can be classified on the basis of the electrical motor, the power converter and the control technique. The main drive types are reviewed. The salient features of each type of drive are pointed out along with their industrial
This paper describes the field oriented control of a salient pole wound field synchronous machine in stator flux coordinates. The procedure for derivation of flux linkage equations along any general rotating axes including stator flux axes is given. The stator flux equations are used to identify the cross-coupling occurring between the axes due to saliency in the machine. The coupling terms are canceled as feedforward terms in the generation of references for current controllers to achieve good decoupling during transients. The design of current controller for stator-flux-oriented control is presented. This paper proposes the method of extending rotor flux closed loop observer for sensorless control of wound field synchronous machine. This paper also proposes a new sensorless control by using stator flux closed loop observer and estimation of torque angle using stator current components in stator flux coordinates. Detailed experimental results from a sensorless 15.8 hp salient pole wound field synchronous machine drive are presented to demonstrate the performance of the proposed control strategy from a low speed of 0.8 Hz to 50 Hz.
Current source inverter (CSI) is an attractive solution in high-power drives. The conventional gate turn-off thyristor (GTO) based CSI-fed induction motor drives suffer from drawbacks such as low-frequency torque pulsation, harmonic heating, and unstable operation at low-speed ranges. These drawbacks can be overcome by connecting a current-controlled voltage source inverter (VSI) across the motor terminal replacing the bulky ac capacitors. The VSI provides the harmonic currents, which results in sinusoidal motor voltage and current even with the CSI switching at fundamental frequency. This paper proposes a CSI-fed induction motor drive scheme where GTOs are replaced by thyristors in the CSI without any external circuit to assist the turning off of the thyristors. Here, the current-controlled VSI, connected in shunt, is designed to supply the volt ampere reactive requirement of the induction motor, and the CSI is made to operate in leading power factor mode such that the thyristors in the CSI are autosequentially turned off. The resulting drive will be able to feed medium-voltage, high-power induction motors directly. A sensorless vector-controlled CSI drive based on the proposed configuration is developed. The experimental results from a 5 hp prototype are presented. Experimental results show that the proposed drive has stable operation throughout the operating range of speeds.
This paper investigates certain novel switching sequences involving division of active vector time for space vector-based pulsewidth modulation (PWM) generation for a voltage source inverter. This paper proposes two new sequences, and identifies all possible sequences, which result in the same average switching frequency as conventional space vector PWM (CSVPWM) at a given sampling frequency. This paper brings out a method for designing hybrid PWM techniques involving multiple sequences to reduce line current ripple. The three proposed hybrid PWM techniques (three-zone PWM, five-zone PWM and seven-zone PWM) employ three, five and seven different sequences, respectively, in every sector. Each sequence is employed in a spatial region within the sector where it results in the lowest rms current ripple over the given sampling period. The proposed techniques lead to a significant reduction in THD over CSVPWM at high line voltages. The five-zone technique results in the lowest THD among real-time techniques with uniform sampling, while the seven-zone technique is the best among real-time techniques with twin sampling rates. The superior harmonic performance of the proposed techniques over CSVPWM and existing bus-clamping PWM techniques is established theoretically as well as experimentally.
This paper describes a vector control scheme for a stand-alone generator based on a wound rotor induction machine with rotor side control. The stand-alone generator refers to an isolated grid feeding a local load. The primary objective of the control scheme is to maintain constant voltage and frequency at the output of the generator irrespective of prime mover speed variation. A novel, simple, and easily implementable sensorless control scheme is proposed. The issue of power quality, which is one of the main concerns of a stand-alone generation system, is also addressed. This is done by incorporating the active filter concept in the control scheme to cancel significant harmonics. A method of unit vector generation for field-oriented control is proposed. A laboratory prototype consisting of back-to-back insulated-gate bipolar transistor converters and a TMS320F240 DSP controller is developed. Detailed experimental results are presented which demonstrate and validate the effectiveness of the proposed scheme.
CSI fed induction motor drives are employed in medium voltage high power applications. One of the major limitations of these drives is the injection of current harmonics into the source, due to the presence of fully controlled ac to dc converter at input stage. There is an increased demand by the industry to modify these drives to meet IEEE 519 standards. This paper proposes a novel CSI drive, in which two identical multilevel inverters are used as active filters, one at the input end and another at the motor terminals, with common dc bus. The active filter at input end provides necessary active current to maintain dc bus. Such an arrangement will ensure sinusoidal input current, sinusoidal motor current and motor voltages. Since the active filter has very high bandwidth, it will be possible to meet the harmonic specifications as per IEEE 519 standards. The proposed drive is simulated and the results are presented. The experimental implementation is in progress. The proposed configuration promises a better alternative compared to other conventional methods like use of passive filters or multi pulse rectifiers at the input stages in terms of cost and performance.
The objective of the present work is to improve the output waveform of three level inverters used in high-power applications, where the switching frequency is very low. This is achieved by maintaining the synchronization, half-wave symmetry, quarter-wave symmetry, and three-phase symmetry in the pulsewidth modulation (PWM) waveforms. The principles of achieving synchronization and symmetries in terms of space vectors for three level inverters are presented. A novel synchronized space vector pulsewidth modulation (SVPWM) algorithms is proposed and verified experimentally. The experimental waveforms of the inverter output voltage and motor no load current for different operating conditions of the drive are presented. The performance measure in terms of the weighted total harmonic distortion (THD) of the line voltage is computed for the linear modulation region of the drive for the proposed algorithm and compared with that of synchronized SVPWM and synchronized sine-triangle pulsewidth modulation (SPWM) technique. The comparative results show that consideration of synchronization and symmetry results in improved THD. Another significant feature of the proposed algorithm is that the symmetry and synchronization leads to self-balancing of the direct current (dc) bus capacitor voltages over every one third cycle of the fundamental
This paper presents the new trend of FPGA (Field programmable Gate Array) based digital platform for the control of power electronic systems. There is a rising interest in using digital controllers in power electronic applications as they provide many advantages over their analog counterparts. A board comprising of Cyclone device EP1C12Q240C8 of Altera is used for developing this platform. The details of this board are presented. This developed platform can be used for the controller applications such as UPS, Induction Motor drives and front end converters. A real time simulation of a system can also be done. An open-loop induction motor drive has been implemented using this board and experimental results are presented.
The basic operation of a wound-rotor induction-motor drive fed by inverters on the stator as well as the rotor side is discussed. Different modes of operations are defined and explained based on power flow on both the sides of the machine. The sensorless motor control scheme consists of V/f-type direct frequency control on one side, with either vector control or direct torque and flux control on the other side. The machine operates up to twice the rated speed in either direction, with full flux and torque, thereby producing up to twice the rated power. Novel frequency profiles are proposed, which ensure that the frequency on either side never drops below a minimum value (set at 12 Hz in this work). Therefore, the estimation of flux can be simply and reliably carried out by integration of voltage, resulting in simple sensorless control. The drive works reliably at all speeds including zero speed and at all loads. Results from a 50-hp prototype drive are presented.