Shape-memory materials hold great potential to impart medical devices with functionalities useful during implantation, locomotion, drug delivery, and removal. However, their clinical translation is limited by a lack of non-invasive and precise methods to trigger and control the shape recovery, especially for devices implanted in deep tissues. In this study, the application of image-guided high-intensity focused ultrasound (HIFU) heating is tested. Magnetic resonance-guided HIFU triggered shape-recovery of a device made of polyurethane urea while monitoring its temperature by magnetic resonance thermometry. Deformation of the polyurethane urea in a live canine bladder (5 cm deep) is achieved with 8 seconds of ultrasound-guided HIFU with millimeter resolution energy focus. Tissue sections show no hyperthermic tissue injury. A conceptual application in ureteral stent shape-recovery reduces removal resistance. In conclusion, image-guided HIFU demonstrates deep energy penetration, safety and speed.
It is increasingly appreciated that the properties of a biomaterial used in intramyocardial injection therapy influence the outcomes of infarcted hearts that are treated. In this report the extended in vivo efficacy of a thermally responsive material that can deliver dual growth factors while providing a slow degradation time and high mechanical stiffness is examined. Copolymers consisting of N-isopropylacrylamide, 2-hydroxyethyl methacrylate, and degradable methacrylate polylactide were synthesized. The release of bioactive basic fibroblast growth factor (bFGF) and insulin-like growth factor 1 (IGF1) from the gel and loaded poly(lactide-co-glycolide) microparticles was assessed. Hydrogel with or without loaded growth factors was injected into 2 week-old infarcts in Lewis rats and animals were followed for 16 weeks. The hydrogel released bioactive bFGF and IGF1 as shown by mitogenic effects on rat smooth muscle cells in vitro. Cardiac function and geometry were improved for 16 weeks after hydrogel injection compared to saline injection. Despite demonstrating that left ventricular levels of bFGF and IGF1 were elevated for two weeks after injection of growth factor loaded gels, both functional and histological assessment showed no added benefit to inclusion of these proteins. This result points to the complexity of designing appropriate materials for this application and suggests that the nature of the material alone, without exogenous growth factors, has a direct ability to influence cardiac remodeling.
Thermoresponsive hydrogels are attractive for their injectability and retention in tissue sites where they may serve as a mechanical support and as a scaffold to guide tissue remodeling. Our objective in this report was to develop a thermoresponsive, biodegradable hydrogel system that would be capable of protein release from two distinct reservoirs--one where protein was attached to the hydrogel backbone, and one where protein was loaded into biodegradable microparticles mixed into the network. Thermoresponsive hydrogels consisting of N-isopropylacrylamide (NIPAAm), 2-hydroxyethyl methacrylate (HEMA), and biodegradable methacrylate polylactide were synthesized along with modified copolymers incorporating 1 mol % protein-reactive methacryloxy N-hydroxysuccinimide (MANHS), hydrophilic acrylic acid (AAc), or both. In vitro bovine serum albumin (BSA) release was studied from hydrogels, poly(lactide-co-glycolide) microparticles, or microparticles mixed into the hydrogels. The synthesized copolymers were able to gel below 37°C and release protein in excess of 3 months. The presence of MANHS and AAc in the copolymers was associated with higher loaded protein retention during thermal transition (45% vs. 22%) and faster release (2 months), respectively. Microspheres entrapped in the hydrogel released protein in a delayed fashion relative to microspheres in saline. The combination of a protein-reactive hydrogel mixed with protein-loaded microspheres demonstrated a sequential release of specific BSA populations. Overall the described drug delivery system combines the advantages of injectability, degradability, extended release, and sequential release, which may be useful in tissue engineering applications.
PURPOSE:Biodegradable elastomers, which can possess favorable mechanical properties and degradation rates for soft tissue engineering applications, are more recently being explored as depots for biomolecule delivery. The objective of this study was to synthesize and process biodegradable, elastomeric poly(ester urethane)urea (PEUU) scaffolds and to characterize their ability to incorporate and release bioactive insulin-like growth factor-1 (IGF-1) and hepatocyte growth factor (HGF). METHODS:Porous PEUU scaffolds made from either 5 or 8 wt% PEUU were prepared with direct growth-factor incorporation. Long-term in vitro IGF-1 release kinetics were investigated in saline or saline with 100 units/ml lipase to simulate in vivo degradation. Cellular assays were used to confirm released IGF-1 and HGF bioactivity. RESULTS:IGF-1 release into saline occurred in a complex multi-phasic manner for up to 440 days. Scaffolds generated from 5 wt% PEUU delivered protein faster than 8 wt% scaffolds. Lipase-accelerated scaffold degradation led to delivery of >90% protein over 9 weeks for both polymer concentrations. IGF-1 and HGF bioactivity in the first 3 weeks was confirmed. CONCLUSIONS:The capacity of a biodegradable elastomeric scaffold to provide long-term growth-factor delivery was demonstrated. Such a system might provide functional benefit in cardiovascular and other soft tissue engineering applications.
Heart failure initiated by coronary artery disease and myocardial infarction (MI) is a widespread, debilitating condition for which there are a limited number of options to prevent disease progression. Intra-myocardial biomaterial injection following MI theoretically provides a means to reduce the stresses experienced by the infarcted ventricular wall, which may alter the pathological remodeling process in a positive manner. Furthermore, biomaterial injection provides an opportunity to concurrently introduce cellular components and depots of bioactive agents. Biologically derived, synthetic and hybrid materials have been applied, as well as materials designed expressly for this purpose, although optimal design parameters, including degradation rate and profile, injectability, elastic modulus and various possible bioactivities, largely remain to be elucidated. This review seeks to summarize the current body of growing literature where biomaterial injection, with and without concurrent pharmaceutical or cellular delivery, has been pursued to improve functional outcomes following MI. The literature to date generally demonstrates acute functional benefits associated with biomaterial injection therapy across a broad variety of animal models and material compositions. Further functional improvements have been reported when cellular or pharmaceutical agents have been incorporated into the delivery system. Despite these encouraging early results, the specific mechanisms behind the observed functional improvements remain to be fully explored and future studies employing hypothesis-driven material design and selection may increase the potential of this approach to alleviate the morbidity and mortality of heart failure.
1Department of Chemistry, Chemical Biology and Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ 07030, USA 2Xylos Corporation, Langhorne, PA 19047, USA 3Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China 4RainDance Technologies Inc., Lexington, MA 02421, USA 5McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA
Biodegradable polyurethane urea (PUU) elastomers are ideal candidates for fabricating tissue engineering scaffolds with mechanical properties akin to strong and resilient soft tissues. PUU with a crystalline poly(ε-caprolactone) (PCL) macrodiol soft segment (SS) showed good elasticity and resilience at small strains (<50%) but showed poor resilience under large strains because of stress-induced crystallization of the PCL segments, with a permanent set of 677 ± 30% after tensile failure. To obtain softer and more resilient PUUs, we used noncrystalline poly(trimethylene carbonate) (PTMC) or poly(δ-valerolactone-co-ε-caprolactone) (PVLCL) macrodiols of different molecular weights as SSs that were reacted with 1,4-diisocyanatobutane and chain extended with 1,4-diaminobutane. Mechanical properties of the PUUs were characterized by tensile testing with static or cyclic loading and dynamic mechanical analysis. All of the PUUs synthesized showed large elongations at break (800-1400%) and high tensile strength (30-60 MPa). PUUs with noncrystalline SSs all showed improved elasticity and resilience relative to the crystalline PCL-based PUU, especially for the PUUs with high molecular weight SSs (PTMC 5400 M(n) and PVLCL 6000 M(n)), of which the permanent deformation after tensile failure was only 12 ± 7 and 39 ± 4%, respectively. The SS molecular weight also influenced the tensile modulus in an inverse fashion. Accelerated degradation studies in PBS containing 100 U/mL lipase showed significantly greater mass loss for the two polyester-based PUUs versus the polycarbonate-based PUU and for PVLCL versus PCL polyester PUUs. Basic cytocompatibility was demonstrated with primary vascular smooth muscle cell culture. The synthesized families of PUUs showed variable elastomeric behavior that could be explained in terms of the underlying molecular design and crystalline behavior. Depending on the application target of interest, these materials may provide options or guidance for soft tissue scaffold development.
The injection of a mechanical bulking agent into the left ventricular (LV) wall of the heart has shown promise as a therapy for maladaptive remodeling of the myocardium after myocardial infarct (MI). The HeartLander robotic crawler presented itself as an ideal vehicle for minimally-invasive, highly accurate epicardial injection of such an agent. Use of the optimal bulking agent, a thermosetting hydrogel developed by our group, presents a number of engineering obstacles, including cooling of the miniaturized injection system while the robot is navigating in the warm environment of a living patient. We present herein a demonstration of an integrated miniature cooling and injection system in the HeartLander crawling robot, that is fully biocompatible and capable of multiple injections of a thermosetting hydrogel into dense animal tissue while the entire system is immersed in a 37°C water bath.
Injectable thermoresponsive hydrogels are of interest for a variety of biomedical applications, including regional tissue mechanical support as well as drug and cell delivery. Within this class of materials there is a need to provide options for eels with stronger mechanical properties as well as variable degradation profiles. To address this need, the hydrolytically labile monomer, methacrylate-polylactide (MAPLA), with an average 2.8 lactic acid units, was synthesized and copolymerized with N-isopropylacrylamide (NIPAAm) and 2-hydroxyethyl methacrylate (HEMA) to obtain bioabsorbable thermally responsive hydrogels. Poly(NIPAAm-co-HEMA-co-MAPLA) with three monomer feed ratios (84/10/6, 82/10/8, and 80/10/10) was synthesized and characterized with NMR, FTIR, and GPC. The copolymers were soluble in saline at reduced temperature (<10 degrees C), forming clear solutions that increased in viscosity with the MAPLA feed ratio. The copolymers underwent sol gel transition at lower critical solution temperatures of 12.4, 14.0, and 16.2 degrees C, respectively, and solidified immediately upon being placed in a 37 degrees C water bath. The warmed hydrogels gradually excluded water to reach final water contents of similar to 45%. The hydrogels as formed were mechanically strong, with tensile strengths as high as 100 kPa and shear moduli of 60 kPa. All three hydrogels were completely degraded (solubilized) in PBS over a 6-7 month period at 37 degrees C, with a higher MAPLA feed ratio resulting in a faster degradation period. Culture of primary vascular smooth muscle cells with degradation solutions demonstrated a lack of cytotoxicity. The synthesized hydrogels provide new options for biomaterial injection therapy where increased mechanical strength and relatively slow resorption rates would be attractive.
Non-woven polyethersulfone (PES) membranes were prepared by electrospinning. After heat treatment and surface activation, the membranes were covalently functionalized with ligands to be used as affinity membranes. The membranes were characterized in terms of fiber diameter, porosity, specific area, pore size, ligand density and binding capacities. To evaluate the binding efficiency of the membrane, dynamic adsorption of bovine serum albumin (BSA) on the Cibacron blue F3GA (CB) functionalized PES membrane was studied. Experimental breakthrough curves were fitted with the theoretical curves based on the plate model to estimate plate height (H(p)) of the affinity membrane. The high value of H(p) (1.6-8 cm) of the affinity membrane implied a poor dynamic binding efficiency, which can be explained by the intrinsic microstructures of the material. Although the electrospun membrane might not be an ideal candidate for the preparative affinity membrane chromatography for large-scale production, it still can be used for fast small-scale protein purification in which a highly efficient binding is not required. Spin columns packed with protein A/G immobilized PES membranes were demonstrated to be capable of binding IgG specifically. SDS-PAGE results demonstrated that the PES affinity membrane had high specific binding selectivity for IgG molecules and low non-specific protein adsorption. Compared with other reported affinity membranes, the PES affinity membrane had a comparable IgG binding capacity of 4.5 mg/ml, and had a lower flow through pressure drop due to its larger pore size. In conclusion, the novel PES affinity membrane is an ideal spin column packing material for fast protein purification.
Quick establishment of a confluent and stable endothelial cells (ECs) layer in the lumen of vascular grafts is critical for long-term patency of small-diameter vascular grafts. The objective of the study was to fabricate tubular nanofiber scaffolds, incorporate ECs onto the lumen of the scaffolds, and establish an animal model to prove the basic concept of using the scaffolds as vascular grafts. Poly(L-lactic acid)-co-poly(epsilon-caprolactone) P(LLA-CL 70:30) tubular nanofiber scaffolds were fabricated by electrospinning onto a rotating mandrel. Collagen was coated onto the scaffolds after air plasma treatment. Structure and mechanical property of the scaffolds were studied by scanning electron microscopy and tensile stress measurement, respectively. Human coronary artery endothelial cells (HCAECs) were rotationally seeded onto the lumen of the scaffolds at the speed of 6 rpm for 4 h through a customized seeding device, followed with static culture. Results showed evenly distributed and well-spread HCAECs throughout the lumen of the scaffold from 1 day onward to 10 days after seeding. Further, HCAECs maintained phenotypic expression of PECAM-1. To prove the basic concept of using the scaffolds as vascular grafts, acellular tubular P(LLA-CL) nanofiber scaffolds (inner diameter 1 mm) were implanted into rabbits to replace the inferior superficial epigastric veins. Results showed the scaffolds sustained the surgical process, kept the structure integrity, and showed the patency for 7 weeks.
Injection of a bulking material into the ventricular wall has been proposed as a therapy to prevent progressive adverse remodeling due to high wall stresses that develop after myocardial infarction. Our objective was to design, synthesize and characterize a biodegradable, thermoresponsive hydrogel for this application based on copolymerization of N-isopropylacrylamide (NIPAAm), acrylic acid (AAc) and hydroxyethyl methacrylate-poly(trimethylene carbonate) (HEMAPTMC). By evaluating a range of monomer ratios, poly(NIPAAm-co-AAc-co-HEMAPTMC) at a feed ratio of 86/4/10 was shown to be ideal since it formed a hydrogel at 37 degrees C, and gradually became soluble over a 5 month period in vitro through hydrolytic cleavage of the PTMC residues. HEMAPTMC, copolymer and degradation product chemical structures were verified by NMR. No degradation product cytotoxicity was observed in vitro. In a rat chronic infarction model, the infarcted left ventricular (LV) wall was injected with the hydrogel or phosphate buffered saline (PBS). In the PBS group, LV cavity area increased and contractility decreased at 8 wk (p<0.05 versus pre-injection), while in the hydrogel group both parameters were preserved during this period. Tissue ingrowth was observed in the hydrogel injected area and a thicker LV wall and higher capillary density were found for the hydrogel versus PBS group. Smooth muscle cells with contractile phenotype were also identified in the hydrogel injected LV wall. The designed poly(NIPAAm-co-AAc-co-HEMAPTMC) hydrogel of this report may thus offer an attractive biomaterial-centered treatment option for ischemic cardiomyopathy.
Recently it has been the main trend for the application of polymer materials in the interdisciplinary tissue engineering area. Polymer materials have shown their versatility and played main roles in constructing tissue engineering scaffolds. This book chapter briefly reviews the materials requirements for tissue engineering application, and focus on polymer materials including both natural and synthetic polymers. The frequently used and newly developed fabrication technologies for constructing tissue engineering scaffolds are described. Some surface modification/functionalization approaches to the tissue engineering scaffolds are also discussed. Recent advances for the development of polymer scaffolds in skin, cartilage, blood vessel, and nerve tissue engineering are also summarized.
A family of injectable, biodegradable, and thermosensitive copolymers based on N-isopropylacrylamide, acrylic acid, N-acryloxysuccinimide, and a macromer polylactide-hydroxyethyl methacrylate were synthesized by free radical polymerization. Copolymers were injectable at or below room temperature and formed robust hydrogels at 37 degrees C. The effects of monomer ratio, polylactide length, and AAc content on the chemical and physical properties of the hydrogel were investigated. Copolymers exhibited lower critical solution temperatures (LCSTs) from 18 to 26 degrees C. After complete hydrolysis, hydrogels were soluble in phosphate buffered saline at 37 degrees C with LCSTs above 40.8 degrees C. Incorporation of type I collagen at varying mass fractions by covalent reaction with the copolymer backbone slightly increased LCSTs. Water content was 32-80% without collagen and increased to 230% with collagen at 37 degrees C. Hydrogels were highly flexible and relatively strong at 37 degrees C, with tensile strengths from 0.3 to 1.1 MPa and elongations at break from 344 to 1841% depending on NIPAAm/HEMAPLA ratio, AAc content, and polylactide length. Increasing the collagen content decreased both elongation at break and tensile strength. Hydrogel weight loss at 37 degrees C was 85-96% over 21 days and varied with polylactide content. Hydrogel weight loss at 37 degrees C was 85-96% over 21 days and varied with polylactide content. Degradation products were shown to be noncytotoxic. Cell adhesion on the hydrogels was 30% of that for tissue culture polystyrene but increased to statistically approximate this control surface after collagen incorporation. These newly described thermoresponsive copolymers demonstrated attractive properties to serve as cell or pharmaceutical delivery vehicles for a variety of tissue engineering applications.
# Basics Relevant to Electrospinning # Electrospinning Process # Modeling of the Electrospinning Process # Characterization # Functionalization of Polymer Nanofibers # Potential Applications # Appendices: # Glossary of Terms # Useful Websites on Electrospinning and Nanofibers