Low-Level Rf Signal Processing For The Next Linear Collider Test Accelerator

PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS(1998)

引用 1|浏览24
暂无评分
摘要
In the X-band accelerator system for the Next Linear Collider Test Accelerator (NLCTA), the Low Level RF (LLRF) drive system must be very phase stable, but concurrently, be very phase agile. Phase agility is needed to make the Stanford Linear Energy Doubler (SLED) power multiplier systems work and to shape the RF waveforms to compensate beam loading in the accelerator sections. Similarly, precision fast phase and amplitude monitors are required to view, track, and feed back on RF signals at various locations throughout the system. The LLRF is composed of several subsystems: the RF Reference System generates and distributes a reference 11.424GHz signal to all of the RF stations, the Signal Processing Chassis creates the RF waveforms with the appropriate phase modulation, and the Phase Detector Assembly measures the amplitude and phase of monitored RF signals. The LLRF is run via VXI instrumentation. These instruments are controlled using HP VEE graphical programming software. Programs have been developed to shape the RF waveform, calibrate the phase modulators and demodulators, and display the measured waveforms. This paper describes these and other components of the LLRF system.
更多
查看译文
关键词
calibration,testing,signal processing,data processing,control system,phase modulation,radio frequency,linear accelerators,graphical programming,phase detector