The Design and Construction of the MICE Spectrometer Solenoids

Bert Wang, Bob Wahrer, Clyde Taylor, L. Xu, J. Y. Chen, M. Wang, Tiki Juang, Michael S. Zisman, Steve P. Virostek,Michael A. Green

IEEE transactions on applied superconductivity(2009)

引用 7|浏览6
暂无评分
摘要
The purpose of the MICE spectrometer solenoid is to provide a uniform field for a scintillating fiber tracker. The uniform field is produced by a long center coil and two short end coils. Together, they produce 4T field with a uniformity of better than 1% over a detector region of 1000 mm long and 300 mm in diameter. Throughout most of the detector region, the field uniformity is better than 0.3%. In addition to the uniform field coils, we have two match coils. These two coils can be independently adjusted to match uniform field region to the focusing coil field. The coil package length is 2544 mm. We present the spectrometer solenoid cold mass design, the powering and quench protection circuits, and the cryogenic cooling system based on using three cryocoolers with re-condensers.