Current Density Imaging Using Directly Measured Harmonic B-Z Data In Mreit

COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE(2013)

引用 3|浏览4
暂无评分
摘要
Magnetic resonance electrical impedance tomography (MREIT) measures magnetic flux density signals through the use of a magnetic resonance imaging (MRI) in order to visualize the internal conductivity and/or current density. Understanding the reconstruction procedure for the internal current density, we directlymeasure the second derivative of B-z data fromthemeasured k-space data, from which we can avoid a tedious phase unwrapping to obtain the phase signal of B-z. We determine optimal weighting factors to combine the derivatives of magnetic flux density data, del B-2(z), measured using the multi-echo train. The proposed method reconstructs the internal current density using the relationships between the induced internal current and the measured del B-2(z) data. Results from a phantom experiment demonstrate that the proposed method reduces the scanning time and provides the internal current density, while suppressing the background field inhomogeneity. To implement the real experiment, we use a phantom with a saline solution including a balloon, which excludes other artifacts by any concentration gradient in the phantom.
更多
查看译文
关键词
magnetic resonance imaging,algorithms,magnetics,electric conductivity,tomography,computational biology,electrodes
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper