Combined PIXE and SEM study of the behaviour of trace elements in gel formed around implant coated with bioactive glass

Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms(2002)

引用 7|浏览3
暂无评分
摘要
Bioactive glasses are used as coating biomaterials to facilitate anchorage of metallic prostheses implanted into the body. The aim of this work is to study the behavior of gel formed in contact with alloys and BVA and BVH bioactive glasses implanted. Cylinders of metallic implants composed by Ti, Al and V, are coated with bioactive glass. Three sheep were implanted for different time length: 3, 6 and 12 months in the femoral epiphysis. Results obtained with particle induced X-ray emission and scanning electron microscopy show that BVA coating induces a better contact between the metallic implant and bone. On the other hand, BVH coating prevents corrosion from the metallic implant.
更多
查看译文
关键词
81.05.Mh,68.35.D,87.64.B,73.20