In the single-fiber-composite (SFC) test, a fiber imbedded in a matrix is loaded in tension, resulting in a fragmentation of the fiber. In the conventional version of this test, the final fiber fragmentation length distribution is used with a micro-mechanical model to determine the average fiber/matrix interfacial shear stress. In the enhanced version of this test, one also determines the applied stress at each fiber fracture, and from this, one can evaluate the strength of the fiber at short gage lengths. In our measurement system, we utilize an acoustic emission (AE) technique to detect the fiber fractures and to locate the fiber breaks and so determine both the fiber failure stresses as well as the fiber fragmentation lengths while the test is in progress. Critical to the success of this test is a broadband AE system that utilizes point-like AE sensors, procedures for evaluatingin situ, the wavespeed of the first wave arrival and signal processing techniques for determining the arrival time of this signal as precisely as possible for a broad range of wave shapes. Here we describe the application of such an enhanced SFC test procedure to investigate the failure of a Nicalon™ fiber in an epoxy matrix.
更多
查看译文
关键词
size effect,fragmentation,fiber/matrix interface,acoustic emission,interfacial shear strength,single-fiber-composite,ae source location,Acoustic emission,AE source location