谷歌浏览器插件
订阅小程序
在清言上使用

Gamma Probe Detection of Ectopic Parathyroid Adenoma

Radiology Case Reports(2008)

引用 6|浏览12
暂无评分
摘要
A 34-year-old man with hypercalcemia had a sestamibi scan that showed increased uptake that appeared to correspond with a 7 mm density in the mediastinum, adjacent to the aortic arch, on chest CT. This lesion was thought to be consistent with an ectopic parathyroid adenoma. Prior to surgical exploration, the patient was injected intravenously with 12.3 millicuries of Tc99m-sestamibi. The lesion identified preoperatively did not show abnormal radionuclide uptake using the intraoperative gamma probe, and was subsequently determined to be a hyperplastic lymph node. However, abnormal activity was localized to the thymus gland, from which an ectopic parathyroid adenoma was successfully excised. The patient recovered without incident. The use of the intraoperative gamma probe was critical in identifying and resecting the ectopic parathyroid adenoma in this patient, and in general, may reduce surgical time and reduce the morbidity and/or complications associated with surgical exploration.
更多
查看译文
关键词
CT,MRI,SPECT,VATS
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要