High Resolution Film Cooling Effectiveness Comparison Of Axial And Compound Angle Holes On The Suction Side Of A Turbine Vane

JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME(2006)

引用 22|浏览1
暂无评分
摘要
Film cooling adiabatic effectiveness for axial and compound angle holes on the suction side of a simulated turbine vane was investigated to determine the relative performance of these configurations. The effect of the surface curvature was also evaluated by comparing to previous curvature studies and flat plate film cooling results. Experiments were conducted for varying coolant density ratio, mainstream turbulence levels, and hole spacing. Results from these measurements showed that for mild curvature, 2r/d approximate to 160, flat plate results are sufficient to predict the cooling effectiveness. Furthermore, the compound angle injection improves adiabatic effectiveness for higher blowing ratios, similar to previous studies using flat plate facilities.
更多
查看译文
关键词
film cooling,compound angle,curvature,turbine vane