A Continuity Equation Based Optical Flow Method For Cardiac Motion Correction In 3d Pet Data

MIAR'10: Proceedings of the 5th international conference on Medical imaging and augmented reality(2010)

引用 9|浏览9
暂无评分
摘要
Cardiac Motion artifacts in PET are a well known problem. The heart undergoes two types of motion, the motion due to respiratory displacement and the motion due to cardiac contraction. These movements lead to blurring of data and to inaccuracies in the quantification. In this study a continuity equation based optical flow method is presented and results on 3D PET patient datasets for cardiac motion correction are presented. The method was evaluated with respect to three criteria: correlation between the images, myocardial thickness and the blood pool activity curves. The results showed that the method was successful in motion correcting the data with high precision.
更多
查看译文
关键词
Motion correction,Optical Flow,PET,CT,Mass Conservation