Development of cryogenic tracking detectors for very high luminosity experiments

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2009)

引用 3|浏览33
暂无评分
摘要
Experimental results and simulations of Charge Collection Efficiency (CCE) of Current Injected Detectors (CIDs) are focused. CID is a concept where the current is limited by the space charge. The injected carriers will be trapped by the deep levels. This induces a stable electric field through the entire bulk regardless of the irradiation fluence the detector has been exposed. Our results show that the CCE of CIDs is about two times higher than of regular detectors when irradiated up to 1×1016cm−2. The higher CCE is achieved already at −50°C temperatures.
更多
查看译文
关键词
Detectors,Radiation hardness,Cryogenic