谷歌浏览器插件
订阅小程序
在清言上使用

Mr Cholangiopancreatography With T2-Weighted Prospective Acquisition Correction Turbo Spin-Echo Sequence Of The Biliary Anatomy Of Potential Living Liver Transplant Donors

AMERICAN JOURNAL OF ROENTGENOLOGY(2008)

引用 38|浏览10
暂无评分
摘要
OBJECTIVE. The objective of our study was to evaluate the ability of a respiratory navigator-triggered T2-weighted turbo spin-echo ( TSE) sequence with a prospective acquisition correction ( PACE) technique for MR cholangiopancreatography ( MRCP) to depict the biliary anatomy of living donor liver transplantation ( LDLT) donors.SUBJECTS AND METHODS. Forty potential LDLT donors who ranged in age from 19 to 54 years were prospectively evaluated with preoperative MRCP. MRCP was performed with a 1.5-T magnetic field using T2-weighted PACE TSE sequence. MRCP source data sets were processed with maximum-intensity-projection ( MIP) and shaded surface display ( SSD) algorithms. Findings were compared with intraoperative cholangiography. Biliary anatomy was classified according to the classification proposed by Huang and colleagues. The sensitivity, specificity, positive predictive value ( PPV), and negative predictive value ( NPV) of MRCP for the detection of aberrant biliary anatomy were calculated.RESULTS. Intraoperative cholangiography and biliary exploration revealed that 27 donor candidates ( 67.5%) had conventional and 13 ( 32.5%) had aberrant biliary anatomy. Two donors ( 5%) had type B biliary anatomy; eight donors ( 20%), type C; two donors ( 5%), type D; and one donor ( 2.5%), unclassified. The sensitivity of MRCP source data sets in differentiating aberrant biliary anatomies from nonaberrant ones was 100%, the specificity was 88.9%, and the accuracy was 92.5%. PPV and NPV were 81.3% and 100%, respectively. The sensitivity of MIP images in differentiating aberrant biliary anatomies was 100%, the specificity was 88.9%, and the accuracy was 92.5%. PPV and NPV were 81.3% and 100%, respectively. The sensitivity, specificity, accuracy, PPV, and NPV of the SSD images in detecting aberrant biliary anatomies were 100%, 77.8%, 85%, 68.4%, and 100%, respectively.CONCLUSION. Preoperative MRCP using a respiratory navigator-triggered T2-weighted TSE sequence with a PACE technique accurately depicts the biliary anatomy in LDLT donors and may guide intraoperative management of the biliary tract.
更多
查看译文
关键词
anatomy,biliary system,liver disease,liver transplantation,living donor liver transplantation,MR cholangiopancreatography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要