An optical sensor for the alignment of the Atlas Muon Spectrometer

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2003)

引用 1|浏览4
暂无评分
摘要
In the Atlas muon spectrometer (ATLAS Technical Proposal, CERN/LHCC/94-43, 15 December 1994, ATLAS Muon Spectrometer Technical Design Report, CERN/LHCC/97-22, 31 May 1997 and http://atlasinfo.cern.ch:80/Atlas/Welcome.html) the alignment system should control the spatial position of the muon chambers with an accuracy of 30μm and 200μrad for a range of ±5mm and ±10mrad. The alignment device described in this paper, called Praxial, fulfills these requirements.
更多
查看译文
关键词
Alignment,Muon,Optical system,Absolute positioning