Tensile Stress Acoustic Constants of Unidirectional Graphite/Epoxy Composites

Tensile Stress Acoustic Constants of Unidirectional Graphite/Epoxy Composites(1990)

引用 3|浏览2
暂无评分
摘要
Previously, the stress acoustic constants (SAC''s) of unidirectional graphite/epoxy composites were measured to determine the nonlinear moduli of this material. These measurements were made under compressive loading in order to obtain the sufficient number of values needed to calculate these moduli. However, because their strength in tension along fiber directions can be several times greater, most composites are used under tensile loading. Thus, it is important to characterize the nonlinear properties of these materials in tension as well. The SAC''s which are defined as the slope of the normalized change in ultrasonic "natural" velocity as a function of stress were measured in a unidirectional laminate of T300/5208 graphite/epoxy. Tensile load was applied along the fiber axis with the ultrasonic waves propagating perpendicular to locked loop ultrasonic interferometer with the nominal frequency of the ultrasonic waves being 2.25 MHz.
更多
查看译文
关键词
ultrasonic wave,epoxy composite,fiber axis,fiber direction,ultrasonic interferometer,compressive loading,tensile stress acoustic constants,nonlinear modulus,epoxy composites,unidirectional graphite,tensile load,stress acoustic constant,nonlinear property,interferometers,wave propagation,carbon fiber,phase lock loop,composite material,tensile stress