Reliability of a new device to assess the oxygen consumption of human respiratory muscles.

MEDICINE AND SCIENCE IN SPORTS AND EXERCISE(1999)

引用 1|浏览4
暂无评分
摘要
Purpose: This study tests the reliability of a new device for assessing the oxygen consumption of the respiratory muscles ((V) over dot O-2 resp.). Methods: Fourteen healthy male volunteers participated in the study. The device consists of an expandable external ventilatory dead space created with pieces of plastic tubing and a spirometer filled with 100% oxygen. It also incorporates a carbon dioxide absorber. Total (V) over dot O-2 ((V) over dot O-2 tot.) was recorded from the spirometric closed circuit and ventilation ((V) over dot (E)), from the spirometer tracing. Fur each subject the test procedure was carried out in duplicate (T1 and T2) after an overnight fast. The dead space was increased at a constant rate of 260 mL every 90 s, and (V) over dot O-2 tot, and (V) over dot (E) increased progressively. Because log (V) over dot O-2 tot, was linearly related to (V) over dot (E), we calculated the slope value (log (V) over dot O-2-(V) over dot (E)) and the Y-intercept ((V) over dot (E) = 0) of the semilog regression representing, respectively, (V) over dot O-2 resp. and metabolic (V) over dot O-2 ((V) over dot O-2 met.). Results: When compared with values in the literature, these values did not differ from those recorded in subjects of a similar age group. The (V) over dot O-2 resp. and (V) over dot O-2 met. calculated in T1 and T2 were not different (90, resp. = 0.0066 +/- 0.0005 for T1 vs 0.0067 +/- 0.0005 log ml . min(-1)/L . min(-1) for T2 and (V) over dot O-2 met. = 269.3 +/- 28.6 for T1 vs 281.9 +/- 24.1 mL . min(-1) for T2). The coefficients of variation were: 25% at T1 and 23% at T2 for (V) over dot O-2 resp. and 34% at T1 and 29% at T2 for (V) over dot O-2 met. Moreover. significant correlations (r = 0.96, P < 0.001 for (V) over dot O-2 resp., r = 0.95, P < 0.001 for (V) over dot O-2 met.), high coefficients of determination (r(2) = 0.92 for (V) over dot O-2 resp., r(2) = 0.90 for (V) over dot O-2 met.) and negligible SEE (0.0005 for (V) over dot O-2 resp., 0.2 ml . min(-1) for (V) over dot O-2 met.) were found between the two tests. When we plotted the mean values of (V) over dot O-2 resp. and (V) over dot O-2 met. measured at T1 and T2 against their respective differences, more than 95% of the slight differences ranged between the limit:, defined by mean value +/- 2 SD, reflecting the small discrepancy between duplicate measurements. Conclusion: The results confirm that the test performed with this device is useful and reliable for assessing the (V) over dot O-2 rasp. in healthy subjects.
更多
查看译文
关键词
dead space loading,breathing work,respiratory energy cost,respiratory muscle efficiency
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要