Design and simulation of 94GHz Magnetron Injection Gun

2012 IEEE 13th International Vacuum Electronics Conference, IVEC 2012(2012)

引用 0|浏览3
暂无评分
摘要
This paper reports the results about a Magnetron Injection Gun(MIG) designed recently. This gun can work at frequency 94GHz for gyrostron. After lots of optimizings and simulations about the structure, at the coefficient of magnetic field 0.8313(3.5755T), beam voltage 24KV, and beam current 2A, it was observed that the electron ratio 1.4, the maximum transverse velocity spread less than 2.7%, the longitudinal velocity about 5.7%. The gun was used for a 94GHz gyrotron, it was obtained that the output power of about 25KW with efficiency 53%(SDC). © 2012 IEEE.
更多
查看译文
关键词
ecr,gun,gyrotron,hpm,mig,magnetic fields,electric potential,mathematical model,cathodes,transverse velocity