Preliminary Analysis Of Three Ulofas Based On The Dual-Functional Lithium Lead Test Blanket Module Configuration In Iter
PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 6(2011)
摘要
Based on the structural design of the Chinese ITER Dual Functional Lithium-Lead Test Blanket Module (DFLL-TBM), Three Unprotected Loss of Flow Accidents (ULOFAs) were investigated preliminarily, assuming that the whole nuclear heat in TBM was carried away by the flowing lithium-lead(LiPb). The results show that the temperature of the first wall (FW) increases rapidly and the maximum temperature appears at the lower part of FW. In the analysis of ULOFAs, the maximum temperature might exceed the melting point of structure material steel. This event must be avoided by the fusion power shutdown system that terminates plasma burn.
更多查看译文
关键词
lithium
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要