Novel Load Frequency Control approach based on Virtual Area Error in a microgrid including PV and battery

National Harbor, MD(2014)

引用 9|浏览1
暂无评分
摘要
In this paper, the frequency of a microgrid, that contains a PV generation and a battery energy storage, is controlled. The paper presents a new approach for Load Frequency Control (LFC) in a microgrid considering the low voltage microgrid as an artificial multi-area network and providing a new strategy which can significantly improve the frequency regulation of the microgrid. A Virtual Area Control Error (VACE) is introduced which utilizes a virtual tie-line and includes the State of Charge (SOC) of the battery to take into consideration the realistic characteristics of the device. The system is simulated using PSCAD. The results show a good improvement in frequency regulation.
更多
查看译文
关键词
battery storage plants,distributed power generation,load regulation,photovoltaic power systems,power generation control,lfc approach,pscad,pv generation,vace,artificial multiarea network,battery soc,battery energy storage,load frequency control approach,low-voltage microgrid,microgrid frequency regulation,state-of-charge,virtual area control error,virtual tie-line,load frequency control,virtual area error,frequency regulation,microgrid,photovoltaic generation,renewable resources,system on chip,frequency control