谷歌浏览器插件
订阅小程序
在清言上使用

Failure analysis for electromagnetic relay contacts adhesion by using XES

Prognostics and System Health Management Conference(2014)

引用 1|浏览2
暂无评分
摘要
Failure analysis is a vital tool used in the development of new products and for the improvement of existing products. And electromagnetic relay is indispensable and widely used in automatic electrical system, which has complex special structure and every component might fail. The failure analysis for electromagnetic relay have a series of methods applying for a number of failure models. The different failure models and failure mechanism of electromagnetic relay have been listed. Then a failure analysis process is proposed for the most common one, contacts adhesion. X-ray emission spectroscopy test is an important step in this process. It can help to observe more detail about morphology. After theoretical analysis, an actual case of failure analysis for electromagnetic relay contacts adhesion by using XES is presented, showing the feasibility and validity of the process. The failure mechanism is also analyzed. At last, some suggestions for improving reliability and avoiding contacts adhesion are given.
更多
查看译文
关键词
X-ray emission spectra,adhesion,electrical contacts,failure analysis,reliability,X-ray emission spectroscopy test,XES,automatic electrical system,electromagnetic relay contact adhesion reliability,failure analysis process,XES,contacts,electromagnetic relay,failure analysis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要