Sequential Organ Failure Assessment in H1N1 pandemic planning.

CRITICAL CARE MEDICINE(2011)

引用 46|浏览3
暂无评分
摘要
Objective: The H1N1 pandemic has highlighted the importance of reliable and valid triage instruments. A Sequential Organ Failure Assessment score of >11 has been proposed to exclude patients from critical care resources quoting an associated mortality of >90%. We sought to assess the mortality associated with this Sequential Organ Failure Assessment threshold and the resource implications of such a triage protocol. Design: Retrospective cohort. Setting: Three multisystem intensive care units. Patients: Consecutive patients admitted from January 2003 to December 2008. Subsequently, a comparison H1N1 cohort was assembled consisting of all patients admitted in 2009 with confirmed H1N1. Interventions: None. Measurements and Main Results: Sequential Organ Failure Assessment was collected daily by use of an electronic bedside clinical information system (n = 10,204 patients, 69,913 patient days). Mean admission Acute Physiology and Chronic Health Evaluation was 19.1. 13.4% of the cohort (9% of total patient days) had an initial Sequential Organ Failure Assessment of >11. Mortality in patients with an initial Sequential Organ Failure Assessment score of >11 was 59% (95% confidence interval: 56%, 62%). The mortality associated with an initial Sequential Organ Failure Assessment >11 across diagnostic categories varied from 29% for poisoning to 67% for neurologic patients. Hospital mortality exceeded 90% only when initial Sequential Organ Failure Assessment was >20 (0.2% of patients). H1N1 patients were younger, had a longer intensive care unit length of stay, and more commonly had a respiratory admission diagnosis than the nonH1N1 cohort. Hospital mortality in H1N1 patients with an initial Sequential Organ Failure Assessment score of >11 was 31% (95% confidence interval: 5%, 56%). Conclusions: A Sequential Organ Failure Assessment score of >11 was not associated with a hospital mortality of >90% at any time during intensive care unit stay. Only a small proportion of patients have the extreme initial Sequential Organ Failure Assessment values associated with a hospital mortality of >90% limiting the usefulness of Sequential Organ Failure Assessment as a triage instrument for pandemic planning. Application of a Sequential Organ Failure Assessment threshold of >11 to the recent H1N1 pandemic would have excluded patients with a markedly lower mortality than seen in a large regional cohort of intensive care unit patients. (Crit Care Med 2011; 39: 827-832)
更多
查看译文
关键词
Sequential Organ Failure Assessment,pandemic,triage
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要