Correcting the gas and particle partitioning of PCDD/F congeners in the flue gas of an iron ore sinter plant.
Journal of Hazardous Materials(2012)
摘要
This study was aimed at developing an approach for correcting the gas and particle partitioning of PCDD/F congeners for samples collected from the flue gas of an iron ore sinter plant. An iron ore sinter plant equipped with an electrostatic precipitator (EP) and a selective catalytic reduction (SCR) was selected. Flue gas samples were collected at EP inlet, EP outlet and SCR outlet. Both particle- and gas-phase PCDD/Fs were analyzed for each collected sample. PCDD/F contents in EP ashes (EP(ash)) were also analyzed and used to correct the gas and particle partitioning of PCDD/F congeners of the collected flue gas samples. Results show that PCDD/Fs in the flue gas were dominated by the gas-phase. Before correction, the removal efficiencies for the gas- and particle-phase PCDD/Fs for EP were -58.1% and 64.3%, respectively, and SCR were 39.4% and 83.9%, respectively. The above results were conflict with the expected results for both EP and SCR indicating the need for correcting the gas and particle partitioning of PCDD/F congeners for all collected flue gas samples. After correction, the removal efficiencies become more reasonable for EP (=4.22% and 97.7%, respectively), and SCR (=54.7% and 62.0%, respectively). The above results confirm the effectiveness of the approach developed by this study.
更多查看译文
关键词
PCDD/Fs,Flue gas,Gas/particle phase partition,Correction approach,Iron ore sinter plant