Radiation Safety Aspects of the Operation of First Three Synchrotron Beam Lines of Indus-2.

Radiation protection dosimetry(2014)

引用 0|浏览10
暂无评分
摘要
Five synchrotron radiation beam lines are commissioned and now under regular operation at the Synchrotron Radiation Source, Indus-2 at Raja Ramanna Centre For Advanced Technology (RRCAT), Indore, India. Nine beam lines are under trial operation, and six beam lines are in the installation stage. In the early phase of installation of beam lines on Indus-2, three bending magnet beam lines, Extended X-ray Absorption Fine Structure (EXAFS, BL-8), Energy Dispersive X-ray Diffraction (EDXRD, BL-11) and Angle Dispersive X-ray Diffraction (ADXRD, BL-12), were installed and commissioned, after approval from Atomic Energy Regulatory Board (AERB), India. These beam lines are pink (BL-8), white (BL-11) and monochromatic (BL-12), which are housed in specially designed shielded hutches. In order to ensure safety of users and other working personnel from ionizing radiations present in these beam lines, several safety systems are incorporated and safety procedures are followed. The paper describes the radiological safety aspects of the three beam lines during its initial commissioning trials and also the measurements on radiation levels carried out in and around the beam line hutches.