Otoacoustic emission (OAE) tests of the medial-olivocochlear reflex (MOCR) in humans were assessed for viability as clinical assays. Two reflection-source OAEs [TEOAEs: transient-evoked otoacoustic emissions evoked by a 47 dB sound pressure level (SPL) chirp; and discrete-tone SFOAEs: stimulus-frequency otoacoustic emissions evoked by 40 dB SPL tones, and assessed with a 60 dB SPL suppressor] were compared in 27 normal-hearing adults. The MOCR elicitor was a 60 dB SPL contralateral broadband noise. An estimate of MOCR strength, MOCR%, was defined as the vector difference between OAEs measured with and without the elicitor, normalized by OAE magnitude (without elicitor). An MOCR was reliably detected in most ears. Within subjects, MOCR strength was correlated across frequency bands and across OAE type. The ratio of across-subject variability to within-subject variability ranged from 2 to 15, with wideband TEOAEs and averaged SFOAEs giving the highest ratios. MOCR strength in individual ears was reliably classified into low, normal, and high groups. SFOAEs using 1.5 to 2 kHz tones and TEOAEs in the 0.5 to 2.5 kHz band gave the best statistical results. TEOAEs had more clinical advantages. Both assays could be made faster for clinical applications, such as screening for individual susceptibility to acoustic trauma in a hearing-conservation program.