Superior Tissue Evolution in Slow-Degrading Scaffolds for Valvular Tissue Engineering

Marieke M. C. P. Brugmans,R. Sarita Soekhradj-Soechit,Daphne van Geemen,Martijn Cox, Carlijn V. C. Bouten, Frank P. T. Baaijens,Anita Driessen-Mol

Tissue Engineering Part A(2016)

引用 16|浏览26
暂无评分
摘要
Synthetic polymers are widely used to fabricate porous scaffolds for the regeneration of cardiovascular tissues. To ensure mechanical integrity, a balance between the rate of scaffold absorption and tissue formation is of high importance. A higher rate of tissue formation is expected in fast-degrading materials than in slow-degrading materials. This could be a result of synthetic cells, which aim to compensate for the fast loss of mechanical integrity of the scaffold by deposition of collagen fibers. Here, we studied the effect of fast-degrading polyglycolic acid scaffolds coated with poly-4-hydroxybutyrate (PGA-P4HB) and slow-degrading poly-ɛ-caprolactone (PCL) scaffolds on amount of tissue, composition, and mechanical characteristics in time, and compared these engineered values with values for native human heart valves. Electrospun PGA-P4HB and PCL scaffolds were either kept unseeded in culture or were seeded with human vascular-derived cells. Tissue formation, extracellular matrix (ECM) composition, remaining scaffold weight, tissue-to-scaffold weight ratio, and mechanical properties were analyzed every week up to 6 weeks. Mass of unseeded PCL scaffolds remained stable during culture, whereas PGA-P4HB scaffolds degraded rapidly. When seeded with cells, both scaffold types demonstrated increasing amounts of tissue with time, which was more pronounced for PGA-P4HB-based tissues during the first 2 weeks; however, PCL-based tissues resulted in the highest amount of tissue after 6 weeks. This study is the first to provide insight into the tissue-to-scaffold weight ratio, therewith allowing for a fair comparison between engineered tissues cultured on scaffolds as well as between native heart valve tissues. Although the absolute amount of ECM components differed between the engineered tissues, the ratio between ECM components was similar after 6 weeks. PCL-based tissues maintained their shape, whereas the PGA-P4HB-based tissues deformed during culture. After 6 weeks, PCL-based engineered tissues showed amounts of cells and ECM that were comparable to the number of human native heart valve leaflets, whereas values were lower in the PGA-P4HB-based tissues. Although increasing in time, the number of collagen crosslinks were below native values in all engineered tissues. In conclusion, this study indicates that slow-degrading scaffold materials are favored over fast-degrading materials to create organized ECM-rich tissues in vitro, which keep their three-dimensional structure before implantation.
更多
查看译文
关键词
Scaffold Materials,Biologic Scaffolds
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要