谷歌浏览器插件
订阅小程序
在清言上使用

Ocular and Cervical Vestibular Evoked Myogenic Potentials (vemps) in Healthy Volunteers: the Intra-, Interobserver, and the Test Re-Test Reliability.

Journal of vestibular research(2015)

引用 7|浏览5
暂无评分
摘要
OBJECTIVE:The aims of the study are to determine the intra-, interobserver, and the test re-test reliability of the cervical and ocular vestibular evoked myogenic potentials (VEMPs).METHODS:Twenty healthy subjects underwent acoustically and forehead tap elicited cervical and ocular VEMPs. The measurements were repeated one week later.RESULTS:The intra- and interobserver reliability of both ocular and cervical VEMPs is excellent. The test re-test reliability of the raw p13n23 peak-to-peak amplitudes of the cervical VEMPs is excellent (ICC: 0.76, 0.87) and the p13 latencies show a good reliability (ICC: 0.56, 0.73). The raw n1p1 peak-to-peak amplitudes of the ocular VEMPs show a fair-to-good test re-test reliability (ICC: 0.51, 0.64) and the n1 and p1 latencies show a poor reliability (ICC: -0.17 ≤ x ≤ 0.44).CONCLUSIONS:The intra- and interobserver reliability of the cervical and ocular VEMPs is excellent. The raw ocular and cervical VEMP peak-to-peak amplitudes are the most reliable parameters, followed by the cervical VEMP latencies. The ocular VEMP latencies shows a poor test re-test reliability. The individual VEMP results, however, remained within normal limits despite the test re-test variability.
更多
查看译文
关键词
Vestibular Evoked Myogenic Potentials (VEMPs),Otoliths,test Re-test,reliability,interobserver
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要