Extremity doses of medical staff involved in interventional radiology and cardiology: Correlations and annual doses (hands and legs)

Radiation Measurements(2011)

引用 26|浏览11
暂无评分
摘要
An intensive measurement campaign was launched in different hospitals in Europe within work package 1 of the ORAMED project (Optimization of RAdiation protection for MEDical staff). Its main objective was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimize staff protection. The monitored procedures were divided in three main categories: cardiac, general angiography and endoscopic retrograde cholangio-pancreatography(ERCP) procedures. Using a common measurement protocol, information such as the protective equipment used (lead table curtain, transparent lead glass ceiling screen, patient shielding, whole body shielding or special cabin etc.) as well as Kerma Area Product (KAP) values and access of the catheter were recorded.
更多
查看译文
关键词
Correlation,Pearson,Product moment,Annual doses,Interventional cardiology,Radiology,Extremity,Eye,Leg,Dose