Mid-Wave Infrared Hyperspectral Imaging Of Unknown Chemical Warfare Agents (Invited Paper)

CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIV(2013)

引用 6|浏览25
暂无评分
摘要
The ability of a stand-off chemical detector to distinguish two different chemical warfare agents is demonstrated in this paper. Using Negative Contrast Imaging, based upon IR absorption spectroscopy, we were able to detect 1 mu l of VX, sulfur mustard and water on a subset of representative surfaces. These experiments were performed at a range of 1.3 metres and an angle of 45 degrees to the surface. The technique employed utilises a Q-switched intracavity MgO:PPLN crystal that generated 1.4 - 1.8 mu m (shortwave) and 2.6 - 3.6 mu m (midwave) infrared radiation (SWIR and MWIR, respectively). The MgO:PPLN crystal has a fanned grating design which, via translation through a 1064 nm pump beam, enables tuning through the SWIR and MWIR wavelength ranges. The SWIR and MWIR beams are guided across a scene via a pair of raster scanned mirrors allowing detection of absorption features within these spectral regions. This investigation exploited MWIR signatures, as they provided sufficient molecular information to distinguish between toxic and benign chemicals in these proof-of-concept experiments.
更多
查看译文
关键词
OPO, hyperspectral imaging, lasers, CWA, grazing angle, IR absorption spectroscopy