Characteristics of Downcomer Boiling Phenomena During the Reflood Phase of a Postulated Large Break LOCA for the APR1400

Volume 2: Thermal Hydraulics(2006)

引用 1|浏览1
暂无评分
摘要
Downcomer boiling phenomena in a conventional pressurized water reactor have an important effect on the transient behavior of a postulated large-break LOCA (LBLOCA), because it can degrade the hydraulic head of the coolant in the downcomer and consequently affect the reflood flow rate for a core cooling. To investigate the thermal hydraulic behavior in the downcomer region, a test program for a downcomer boiling is being progressed in the reflood phase of a postulated LBLOCA. For this, the test facility was designed as a one side heated rectangular test section which adopts a full-pressure, full-height, and full-size downcomer-gap approach, but with the circumferential length reduced 47.08-fold. The test was performed by dividing it into two-phases: (I) visual observation and acquisition of the global two-phase flow parameters and (II) measurement of the local two-phase flow parameters on the measuring planes along five elevations. In the present paper, the test results of Phase-I and parts of Phase-II were introduced.
更多
查看译文
关键词
boiling
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要