Iter Generic Diagnostic Upper Port Plug Nuclear Heating And Personnel Dose Rate Assesment Neutronics Analysis Using The Attila Discrete Ordinates Code

2009 23RD IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING(2009)

引用 2|浏览3
暂无评分
摘要
Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of a large aperture diagnostic were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture. The neutronics discrete-ordinates code ATTILA (R) and SEVERIAN (R) (the ATTILA parallel processing version) was used Material properties and the 500 MW D-T volume source were taken from the ITER "Brand Model" MCNP benchmark model. A biased quadrature set equivelant to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy sub-grouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and Large Aperture cases. The Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 mu Sv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 mu Sv/hr but fell below the limit to 90 mu Sv/hr 2-weeks later. The Large Aperture style shielding model exhibited higher and more persistent dose rates. After 1-day the dose rate was 230 mu Sv/hr but was still at 120 mu Sv/hr 4-weeks later.
更多
查看译文
关键词
scattering,monte carlo methods,heating,neutrons,shielding,plasma physics,cad,material properties,plasma diagnostics,infrared,tin,dosimetry,parallel processing,apertures,design automation,solid modeling
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要