Effect Of Endwall Contouring On A Transonic Turbine Blade Passage: Part 2-Heat Transfer Performance

Journal of Turbomachinery-transactions of The Asme(2012)

引用 17|浏览1
暂无评分
摘要
Contouring of turbine endwalls has been widely studied for aerodynamic performance improvement of turbine passages. However, it is equally important to investigate the effect of contouring on endwall heat transfer, because a substantial increase in endwall heat transfer due to contouring will render the design impractical. In this paper, the effect of contouring on endwall heat transfer performance of a high-turning HP-turbine blade passage, operating under transonic exit Mach number conditions, is reported. Three endwall geometries were experimentally investigated at three different passage exit Mach numbers, 0.71, 0.88(design) and 0.95, for their heat transfer performance. One endwall is a non-contoured baseline endwall and the other two are contoured endwall geometries. One of the contoured endwall geometry was generated with the goal of reduction in stagnation pressure losses and the other was generated with the goal of reduced overall heat transfer through the endwall. The experiments were carried out in Virginia Tech's transient, blow down, transonic linear cascade facility. Endwall surface temperatures were measured using infrared thermography technique. Local heat transfer coefficient values were calculated using the measured temperatures. The heat transfer coefficient values were then related to the endwall geometries using a camera matrix model. The measurement technique and the methodology for the post-processing of the heat transfer coefficient data have. been presented in detail. Details of the flow behavior for these endwalls were obtained using CFD simulations and have been used to assist the interpretation of the experimental results. In this study, the heat transfer performance of the contoured endwalls in comparison to the non-contoured baseline case is presented. Both the contoured endwalls demonstrated a significant reduction in the overall average heat transfer coefficient values. The surface heat transfer coefficient distributions also indicated a reduction in the level of hot spots for most of the endwall surface. However, increase in the heat transfer coefficient values was observed especially in the area near the leading edge. The results indicate that, in addition to a probable improvement in aerodynamic performance, endwall contouring may also be used to improve the heat transfer performance of turbine passages. Additionally, aerodynamic behavior of these endwalls is discussed in detail in the companion paper GT2012-68425, "Effect of endwall contouring on a transonic turbine endwall: Part 1 Aerodynamic performance."
更多
查看译文
关键词
heat transfer,turbine blades
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要