Transfemoral implantation of CoreValve Evolut-R aortic prosthesis in patient with prior ball-cage mechanical mitral valve prosthesis.

Cardiovascular Revascularization Medicine(2016)

引用 7|浏览6
暂无评分
摘要
Transcatheter aortic valve replacement remains challenge in patients with ball-cage-type mechanical valve in mitral position. Potential under-expansion of the percutaneous valve and interaction between the mitral ball-cage mechanical valve tilted towards the left ventricular outflow tract and the percutaneous valve adds risk during and after implantation. We report a successful implantation of the novel CoreValve Evolut-R self-expanding in a patient with severe aortic stenosis and a mitral Starr-Edwards mechanical valve implanted 28years ago.
更多
查看译文
关键词
Ball-Caged Mechanical Mitral Valve Prosthesis,,Aortic stenosis,,Transcatheter valve replacement