A New Hydrogen Sensor Based on SNS Fiber Interferometer with Pd/WO3 Coating.

SENSORS(2017)

引用 16|浏览12
暂无评分
摘要
This paper presents a new hydrogen sensor based on a single mode-no core-single mode (SNS) fiber interferometer structure. The surface of the no core fiber (NCF) was coated by Pd/WO3 film to detect the variation of hydrogen concentration. If the hydrogen concentration changes, the refractive index of the Pd/WO3 film as well as the boundary condition for light propagating in the NCF will all be changed, which will then cause a shift into the resonant wavelength of interferometer. Therefore, the hydrogen concentration can be deduced by measuring the shift of the resonant wavelength. Experimental results demonstrated that this proposed sensor had a high detection sensitivity of 1.26857 nm/%, with good linearity and high accuracy (maximum 0.0055% hydrogen volume error). Besides, it also possessed the advantages of simple structure, low cost, good stability, and repeatability.
更多
查看译文
关键词
fiber interferometer,no core fiber (NCF),hydrogen sensor,Pd/WO3 film