谷歌浏览器插件
订阅小程序
在清言上使用

The Role of Multidetector Computed Tomography and the Forced Oscillation Technique in Assessing Lung Damage in Adults with Cystic Fibrosis.

Respiratory care(2017)

引用 6|浏览18
暂无评分
摘要
BACKGROUND: With increased survival rates and the consequent emergence of an adult population with cystic fibrosis (CF), developing novel tools for periodic evaluations of these patients has become a new challenge. Thus, we sought to determine the contribution of lung-volume quantification using multidetector computed tomography (CT) in adults with CF and to investigate the association between structural changes and functional abnormalities. METHODS: This was a cross-sectional study in which 21 adults with CF and 22 control subjects underwent lung-volume quantification using multidetector CT. Voxel densities were divided into 4 bands: −1,000 to −900 Hounsfield units (HU) (hyperaerated region), −900 to −500 HU (normally aerated region), −500 to −100 HU (poorly aerated region), and −100 to 100 HU (non-aerated region). In addition, all participants performed pulmonary function tests including spirometry, body plethysmography, diffusion capacity for carbon monoxide, and the forced oscillation technique. RESULTS: Adults with CF had more non-aerated regions and poorly aerated regions with lung-volume quantification using multidetector CT than controls. Despite these abnormalities, total lung volume measured by lung-volume quantification using multidetector CT did not differ between subjects and controls. Total lung capacity (TLC) measured by body plethysmography correlated with both total lung volume (rs = 0.71, P < .001) and total air volume (rs = 0.71, P < .001) as measured with lung-volume quantification using multidetector CT. While the hyperaerated regions correlated with the functional markers of gas retention in the lungs (increased residual volume (RV) and RV/TLC ratio), the poorly aerated regions correlated with the resistive parameters measured by the forced oscillation technique (increased intercept resistance and mean resistance). We also observed a correlation between normally aerated regions and highest pulmonary diffusion values (rs = 0.68, P < .001). CONCLUSIONS: In adults with CF, lung-volume quantification using multidetector CT can destimate the lung volumes of compartments with different densities and determine the aerated and non-aerated contents of the lungs; furthermore, lung-volume quantification using multidetector CT is clearly related to pulmonary function parameters.
更多
查看译文
关键词
cystic fibrosis,diagnostic imaging,respiratory function tests,forced oscillation technique
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要