Quantitative Flow Imaging in Human Umbilical Vessels In Utero Using Nongated 2D Phase Contrast MRI.

JOURNAL OF MAGNETIC RESONANCE IMAGING(2018)

引用 7|浏览7
暂无评分
摘要
BackgroundVolumetric assessment of afferent blood flow rate provides a measure of global organ perfusion. Phase-contrast magnetic resonance imaging (PCMRI) is a reliable tool for volumetric flow quantification, but given the challenges with motion and lack of physiologic gating signal, such studies, in vivo on the human placenta, are scant. PurposeTo evaluate and apply a nongated (ng) PCMRI technique for quantifying blood flow rates in utero in umbilical vessels. Study TypeProspective study design. Study PopulationTwenty-four pregnant women with median gestational age (GA) 30 4/7 weeks and interquartile range (IQR) 8 1/7 weeks. Field Strength/SequenceAll scans were performed on a 3.0T Siemens Verio system using the ng-PCMRI technique. AssessmentThe GA-dependent increase in umbilical vein (UV) and arterial (UA) flow was compared to previously published values. Systematic error to be expected from ng-PCMRI, in the context of pulsatile UA flow and partial voluming, was studied through Monte-Carlo simulations, as a function of resolution and number of averages. Statistical TestsCorrelation between the UA and UV was evaluated using a generalized linear model. ResultsSimulations showed that ng-PCMRI measurement variance reduced by increasing the number of averages. For vessels on the order of 2 voxels in radius, partial voluming led to 10% underestimation in the flow. In fetuses, the average flow rates in UAs and UV were measured to be 203 80 ml/min and 232 92 ml/min and the normalized average flow rates were 140 59 ml/min/kg and 155 57 ml/min/kg, respectively. Excellent correlation was found between the total arterial flow vs. corresponding venous flow, with a slope of 1.08 (P = 0.036). Data ConclusionNg-PCMRI can provide accurate volumetric flow measurements in utero in the human umbilical vessels. Care needs to be taken to ensure sufficiently high-resolution data are acquired to minimize partial voluming-related errors. Level of Evidence: 2 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.
更多
查看译文
关键词
fetal umbilical vessels,Monte Carlo simulations,nongated phase contrast MRI,partial volume effects,pulsatility,volumetric umbilical flow
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要