Shear wave elastography for liver fibrosis in chronic hepatitis B: Adapting the cut-offs to alanine aminotransferase levels improves accuracy

European radiology(2018)

引用 31|浏览16
暂无评分
摘要
Objectives To determine and validate alanine aminotransferase (ALT)-adapted dual cut-offs of liver stiffness measurements (LSMs) for assessing liver fibrosis with two-dimensional shear wave elastography (2D-SWE) in patients with chronic hepatitis B (CHB) infection. Methods Patients with CHB infection who underwent liver biopsy to assess liver fibrosis were consecutively included. 2D-SWE confirmation thresholds with a positive likelihood ratio ≥10 and 2D-SWE exclusion thresholds with a negative likelihood ratio ≤0.1 were identified to rule in or rule out significant fibrosis and cirrhosis, respectively. Results The first 515 patients (index cohort) and the next 421 patients (validation cohort) were included in the final analysis. The low and high cut-offs to rule out and rule in patients with significant fibrosis (≥ F2) were 5.4 kPa and 9.0 kPa, respectively, in patients with ALT levels ≤ 2 × the upper limit of normal (ULN) and 7.1 kPa and 11.2 kPa in patients with ALT levels > 2 × ULN. For cirrhosis (F4), the corresponding values were 8.1 kPa and 12.3 kPa in patients with ALT levels ≤ 2 × ULN and 11.9 kPa and 24.7 kPa in patients with ALT levels > 2 × ULN. The dual cut-off values showed an overall accuracy of more than 90% for diagnosis of the presence or absence of significant fibrosis and cirrhosis in the index and validation cohorts. There were no significant differences in the accuracy values between the cohorts (all p >0.05). Conclusion The ALT-adapted dual cut-offs of LSMs showed high accuracy for diagnosis of the presence or absence of significant fibrosis and cirrhosis in patients with CHB infection. Key Points • The ALT-adapted dual cut-off values of LSMs showed high accuracy for diagnosis of the presence or absence of significant fibrosis and cirrhosis. • ALT levels did not influence the overall diagnostic accuracy for predicting significant fibrosis and cirrhosis. • The ALT-adapted dual cut-offs in patients with ALT levels > 2 × ULN were markedly higher than those in patients with ALT levels ≤ 2 × ULN.
更多
查看译文
关键词
Elasticity imaging techniques,Ultrasonography,Hepatitis B,Alanine transaminase,Sensitivity and specificity
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要