Simultaneous Measurement Of Delta C-13, Delta O-18 And Delta O-17 Of Atmospheric Co2 - Performance Assessment Of A Dual-Laser Absorption Spectrometer

ATMOSPHERIC MEASUREMENT TECHNIQUES(2021)

引用 5|浏览1
暂无评分
摘要
Using laser absorption spectrometry for the measurement of stable isotopes of atmospheric CO2 instead of the traditional isotope ratio mass spectrometry method decreases sample preparation time significantly, and uncertainties in the measurement accuracy due to CO2 extraction and isobaric interferences are avoided. In this study we present the measurement performance of a new dual-laser instrument developed for the simultaneous measurement of the delta C-13, delta O-18 and delta O-17 of atmospheric CO2 in discrete air samples, referred to as the Stable Isotopes of CO2 Absorption Spectrometer (SICAS). We compare two different calibration methods: the ratio method, based on the measured isotope ratio and a CO2 mole fraction dependency correction, and the isotopologue method, based on measured isotopologue abundances. Calibration with the ratio method and isotopologue method is based on three different assigned whole-air references calibrated on the VPDB (Vienna Pee Dee Belemnite) and the WMO 2007 (World Meteorological Organization) scale for their stable isotope compositions and their CO2 mole fractions, respectively. An additional quality control tank is included in both methods to follow long-term instrument performance. Measurements of the quality control tank show that the measurement precision and accuracy of both calibration methods is of similar quality for delta C-13 and delta O-18 measurements. During one specific measurement period the precision and accuracy of the quality control tank reach WMO compatibility requirements, being 0.01% for delta C-13 and 0.05% for delta O-18. Uncertainty contributions of the scale uncertainties of the reference gases add another 0.03% and 0.05% to the combined uncertainty of the sample measure- ments. Hence, reaching WMO compatibility for sample measurements on the SICAS requires reduction of the scale uncertainty of the reference gases used for calibration. An intercomparison of flask samples over a wide range of CO2 mole fractions has been conducted with the Max Planck Institute for Biogeochemistry, resulting in a mean residual of 0.01% and -0:01% and a standard deviation of 0.05% and 0.07% for the delta C-13 measurements calibrated using the ratio method and the isotopologue method, respectively. The delta O-18 could not be compared due to depletion of the delta O-18 signal in our sample flasks because of storage times being too long. Finally, we evaluate the potential of our Delta O-17 measurements as a tracer for gross primary production by vegetation through photosynthesis. Here, a measurement precision of < 0 :01% would be a prerequisite for capturing seasonal variations in the Delta O-17 signal. Lowest standard errors for the delta O-17 and Delta O-17 of the ratio method and the isotopologue method are 0.02% and 0.02% and 0.01% and 0.02 %, respectively. The accuracy results show consequently results that are too enriched for both the delta O-17 and Delta O-17 measurements for both methods. This is probably due to the fact that two of our reference gases were not measured directly but were determined indirectly. The ratio method shows residuals ranging from 0.06% to 0.08% and from 0.06% to 0.1% for the delta O-17 and Delta O-17 results, respectively. The isotopologue method shows residuals ranging from 0.04% to 0.1% and from 0.05% to 0.13% for the delta O-17 and Delta O-17 results, respectively. Direct determination of the delta O-17 of all reference gases would improve the accuracy of the delta O-17 and thereby of the Delta O-17 measurements.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要