Renal Artery Stenting Using Co2 Gas Angiography In Combination With Iodinated Contrast Angiography

INTERNAL MEDICINE(2016)

引用 3|浏览8
暂无评分
摘要
A 76-year-old woman was hospitalized repeatedly due to unexplained heart failure. On admission, she had hypertensive acute heart failure. Her symptoms disappeared promptly after the initial treatment; however, her systolic blood pressure remained at over 160 mmHg despite her taking three antihypertensive drugs. Closer examination revealed hemodynamically significant right renal artery stenosis and a lack of left kidney function. We performed percutaneous transluminal renal angioplasty using CO2 angiography in combination with iodinated contrast agents. The patient's renal function and blood pressure improved, however, CO2 gas-induced mild ischemic colitis occurred. We discuss the possibility of the use of combined iodinated contrast angiography and CO2 angiography to avoid contrast-induced nephropathy and the complications peculiar to CO2 angiography.
更多
查看译文
关键词
renal artery stenosis, renal artery stenting, CO2 angiography