Outcomes in Patients with Left Ventricular Assist Devices, Pacemakers, and Implantable Cardioverter Defibrillators Undergoing Single Balloon Enteroscopy.

SOUTHERN MEDICAL JOURNAL(2019)

引用 0|浏览4
暂无评分
摘要
Objectives: Obscure overt gastrointestinal bleeding can be challenging to evaluate in patients with electronic cardiac devices such as continuous flow left ventricular assist devices (LVADs), pacemakers (PPMs), and implantable cardioverter defibrillators (ICDs). Limited data exist on the utility and safety of single balloon enteroscopy (SBE) in patients with cardiac devices. We aimed to evaluate the safety, efficacy, diagnostic, and therapeutic outcomes of the aforementioned devices in patients undergoing SBE. Methods: Aretrospective studywas performed using the medical records of 57 patients undergoing SBE at our institution from 2010 to 2014. Patients were divided into two groups: those with cardiac devices and those without. Data on comorbidities, complications, findings, diagnostic, and therapeutic yield were compared. t Test and logistic regression assessed the association between dependent and independent variables. For continuous data, the results were summarized as mean difference and standard deviation. For dichotomous data, the results were summarized as odds ratio and 95% confidence intervals. Results: The overall age in patients with cardiac devices was 67.89 +/- 6.96 versus 66.03 +/- 11.95 years in the control. The cardiac device group was composed of 42.1% women; the control comprised 21.1% women. There were 19 patientswith cardiac devices; 8 (LVAD+ICD), 1 (LVAD+PPM+ICD), 2 (PPM + ICD), 6 (PPM), 2 (ICD); 38 patients were in the control group. Patients with cardiac devices were hospitalized more often than patients without devices; this finding was not statistically significant (odds ratio 1.826, 95% confidence interval 0.544-6.128, P = 0.389). Procedure times were longer in the cardiac device group, 65.16 +/- 49.92 minutes, when compared with the control, 57.40 +/- 20.42, but it also did not reach statistical significance (mean difference 7.758, 95% confidence interval -11.360 to 26.876, P = 0.049). There was no statistically significant difference in major or minor events between patients with cardiac devices and the control group. Diagnostic and therapeutic yield and rebleeding rates were similar across both groups. Conclusions: Patients in the cardiac device group did not appear to be at any more significant risk than thosewithout cardiac devices. Furthermore, diagnostic and therapeutic yield and rebleeding rates appear to be similar across both groups. Clinicians may perform SBE in these patients safely and effectively, with good overall outcomes.
更多
查看译文
关键词
enteroscopy,implantable cardioverter defibrillator,left ventricular assist device,pacemaker,small bowel bleeding
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要