Comparative Evaluation of Three TSPO PET Radiotracers in a LPS-Induced Model of Mild Neuroinflammation in Rats

Molecular Imaging and Biology(2016)

引用 71|浏览22
暂无评分
摘要
Purpose Over the past 20 years, neuroinflammation (NI) has increasingly been recognised as having an important role in many neurodegenerative diseases, including Alzheimer’s disease. As such, being able to image NI non-invasively in patients is critical to monitor pathological processes and potential therapies targeting neuroinflammation. The translocator protein (TSPO) has proven a reliable NI biomarker for positron emission tomography (PET) imaging. However, if TSPO imaging in acute conditions such as stroke provides strong and reliable signals, TSPO imaging in neurodegenerative diseases has proven more challenging. Here, we report results comparing the recently developed TSPO tracers [ 18 F]GE-180 and [ 18 F]DPA-714 with (R)-[ 11 C]PK11195 in a rodent model of subtle focal inflammation. Procedures Adult male Wistar rats were stereotactically injected with 1 μg lipopolysaccharide in the right striatum. Three days later, animals underwent a 60-min PET scan with (R)-[ 11 C]PK11195 and [ 18 F]GE-180 ( n = 6) or [ 18 F]DPA-714 ( n = 6). Ten animals were scanned with either [ 18 F]GE-180 ( n = 5) or [ 18 F]DPA-714 ( n = 5) only. Kinetic analysis of PET data was performed using the simplified reference tissue model (SRTM) with a contralateral reference region or a novel data-driven input to estimate binding potential BP ND . Autoradiography and immunohistochemistry were performed to confirm in vivo results. Results At 40–60 min post-injection, [ 18 F]GE-180 dual-scanned animals showed a significantly increased core/contralateral uptake ratio vs . the same animals scanned with (R)-[ 11 C]PK11195 (3.41 ± 1.09 vs . 2.43 ± 0.39, p = 0.03); [ 18 ]DPA-714 did not (2.80 ± 0.69 vs . 2.26 ± 0.41). Kinetic modelling with a contralateral reference region identified significantly higher binding potential (BP ND ) in the core of the LPS injection site with [ 18 F]GE-180 but not with [ 18 F]DPA-714 vs . (R)-[ 11 C]PK11195. A cerebellar reference region and novel data-driven input to the SRTM were unable to distinguish differences in tracer BP ND . Conclusions Second-generation TSPO-PET tracers are able to accurately detect mild-level NI. In this model, [ 18 F]GE-180 shows a higher core/contralateral ratio and BP ND when compared to (R)-[ 11 C]PK11195, while [ 18 F]DPA-714 did not.
更多
查看译文
关键词
TSPO,Inflammation,LPS,Second-generation tracers,Preclinical kinetic modelling
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要