A 32-channel front-end ASIC for GEM detectors used in beam monitoring applications

JOURNAL OF INSTRUMENTATION(2017)

引用 2|浏览35
暂无评分
摘要
A multichannel, mixed-signal, front-end ASIC for GEM detectors, intended for beam monitoring in hadron therapy applications, has been designed and prototyped in a standard 0.35 mu m CMOS technology. The analog channels are based on the classic CSA + shaper processing chain, followed by a peak detector which can work as an analog memory, to simplifiy the analog-to-digital conversion of the peak voltage of the output pulse, proportional to the energy of the detected event. The available hardware resources include an 8-bit A/D converter and a standard-cell digital part, which manages the read-out procedure, in sparse or serial mode. The ASIC is self-triggered and transfers energy and address data to the external DAQ via a fast 100 MHz LVDS link. Preliminary characterization results show that the non-linearity error is limited to 5% for a maximum input charge of about 70 fC, the measured ENC is about 1400(-) and the time jitter of the trigger signal generated in response to an injected charge of 60 fC is close to 200 ps.
更多
查看译文
关键词
Analogue electronic circuits,CMOS readout of gaseous detectors,Front-end electronics for detector readout